Development and characterization of a tissue equivalent plastic scintillator based dosimetry system.

M P Petric1, J L Robar, B G Clark.   

Abstract

High precision techniques in radiation therapy, such as intensity modulated radiation therapy, offer the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in many of these techniques, however, often lead to more challenging quality assurance with dose verification being labor-intensive and time consuming. A prototype dose verification system has been developed using a tissue equivalent plastic scintillator that provides easy-to-acquire, rapid, digital dose measurements in a plane perpendicular to the beam. The system consists of a water-filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a silver coated plastic mirror to reflect scintillation light towards a viewing window where it is captured using a charge coupled device camera and a personal computer. Optical photon spread is removed using a microlouvre optical collimator and by deconvolving a glare kernel from the raw images. A characterization of the system was performed that included measurements of linear output response, dose rate dependence, spatial linearity, effective pixel size, signal uniformity and both short- and long-term reproducibility. The average pixel intensity for static, regular shaped fields between 3 cm X 3 cm and 12 cm x 12 cm imaged with the system was found to be linear in the dose delivered with linear regression analysis yielding a correlation coefficient r2 > 0.99. Effective pixel size was determined to be 0.53 mm/pixel. The system was found to have a signal uniformity of 5.6% and a long-term reproducibility/stability of 1.7% over a 6 month period. The system's ability to verify a dynamic treatment field was evaluated using 60 degrees dynamic wedged fields and comparing the results to two-dimensional film dosimetry. Results indicate agreement with two-dimensional film dosimetry distributions within 8% inside the field edges. With further development, this system promises to provide a fast, directly digital, and tissue equivalent alternative to current dose verification systems.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16485414     DOI: 10.1118/1.2140118

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

Authors:  Louis Archambault; Tina Marie Briere; Sam Beddar
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

2.  Liquid scintillator for 2D dosimetry for high-energy photon beams.

Authors:  Falk Pönisch; Louis Archambault; Tina Marie Briere; Narayan Sahoo; Radhe Mohan; Sam Beddar; Michael T Gillin
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Simulation of the precision limits of plastic scintillation detectors using optimal component selection.

Authors:  Frédéric Lacroix; Luc Beaulieu; Louis Archambault; A Sam Beddar
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization.

Authors:  Frédéric Lacroix; A Sam Beddar; Mathieu Guillot; Luc Beaulieu; Luc Gingras
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

5.  Performance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems.

Authors:  Chinmay D Darne; Fahed Alsanea; Daniel G Robertson; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2017-06-23       Impact factor: 3.609

6.  Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry.

Authors:  Wook Jae Yoo; Jinsoo Moon; Kyoung Won Jang; Ki-Tek Han; Sang Hun Shin; Dayeong Jeon; Jang-Yeon Park; Byung Gi Park; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2012-05-14       Impact factor: 3.576

7.  Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with the rotation of the gantry for helical tomotherapy.

Authors:  Masatoshi Hashimoto; Masahiro Uematsu; Makiko Ito; Yukihiro Hama; Takayuki Inomata; Masahiro Fujii; Teiji Nishio; Naoki Nakamura; Keiichi Nakagawa
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

8.  Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

Authors:  Mansour Almurayshid; Yusuf Helo; Andrzej Kacperek; Jennifer Griffiths; Jem Hebden; Adam Gibson
Journal:  J Appl Clin Med Phys       Date:  2017-07-29       Impact factor: 2.102

9.  Development of a time-resolved mirrorless scintillation detector.

Authors:  Wonjoong Cheon; Hyunuk Jung; Moonhee Lee; Jinhyeop Lee; Sung Jin Kim; Sungkoo Cho; Youngyih Han
Journal:  PLoS One       Date:  2021-02-12       Impact factor: 3.240

10.  High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation.

Authors:  Sree Bash Chandra Debnath; Carole Fauquet; Agnes Tallet; Anthony Goncalves; Sébastien Lavandier; Franck Jandard; Didier Tonneau; Julien Darreon
Journal:  Med Phys       Date:  2020-01-23       Impact factor: 4.071

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.