Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy.

W Scott Ingram1, Daniel Robertson2, Sam Beddar1.   

Abstract

Liquid scintillators are a promising detector for high-resolution three-dimensional proton therapy dosimetry. Because the scintillator comprises both the active volume of the detector and the phantom material, an ideal scintillator will exhibit water equivalence in its radiological properties. One of the most fundamental of these is the scintillator's stopping power. The objective of this study was to compare calculations and measurements of scintillator-to-water stopping power ratios to evaluate the suitability of the liquid scintillators BC-531 and OptiPhase HiSafe 3 for proton dosimetry. We also measured the relative scintillation output of the two scintillators. Both calculations and measurements show that the linear stopping power of OptiPhase is significantly closer to water than that of BC-531. BC-531 has a somewhat higher scintillation output. OptiPhase can be mixed with water at high concentrations, which further improves its scintillator-to-water stopping power ratio. However, this causes the solution to become cloudy, which has a negative impact on the scintillation output and spatial resolution of the detector. OptiPhase is preferred over BC-531 for proton dosimetry because its density and scintillator-to-water stopping power ratio are more water equivalent.

Entities:  

Keywords:  SRIM; Scintillation dosimetry; liquid scintillators; proton therapy

Year:  2015        PMID: 25705066      PMCID: PMC4332394          DOI: 10.1016/j.nima.2014.12.004

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  14 in total

1.  New water equivalent liquid scintillation solutions for 3D dosimetry.

Authors:  A S Kirov; S Shrinivas; C Hurlbut; J F Dempsey; W R Binns; J L Poblete
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

2.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

3.  The three-dimensional scintillation dosimetry method: test for a 106Ru eye plaque applicator.

Authors:  A S Kirov; J Z Piao; N K Mathur; T R Miller; S Devic; S Trichter; M Zaider; C G Soares; T LoSasso
Journal:  Phys Med Biol       Date:  2005-06-22       Impact factor: 3.609

4.  Development of an easy-to-handle range measurement tool using a plastic scintillator for proton beam therapy.

Authors:  Yasuhiro Fukushima; Minoru Hamada; Teiji Nishio; Koichi Maruyama
Journal:  Phys Med Biol       Date:  2006-10-26       Impact factor: 3.609

5.  Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.

Authors:  Uwe Titt; Yuanshui Zheng; Oleg N Vassiliev; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2007-12-28       Impact factor: 3.609

6.  Quality assurance of proton beams using a multilayer ionization chamber system.

Authors:  Sandeep Dhanesar; Narayan Sahoo; Matthew Kerr; M Brad Taylor; Paige Summers; X Ronald Zhu; Falk Poenisch; Michael Gillin
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

7.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

8.  An analytical approximation of the Bragg curve for therapeutic proton beams.

Authors:  T Bortfeld
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

9.  Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

Authors:  Rui Zhang; Phillip J Taddei; Markus M Fitzek; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-04-06       Impact factor: 3.609

10.  Quenching correction for volumetric scintillation dosimetry of proton beams.

Authors:  Daniel Robertson; Dragan Mirkovic; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

View more
  2 in total

1.  Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.

Authors:  CheukKai Hui; Daniel Robertson; Fahed Alsanea; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2015-07-30

2.  Performance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems.

Authors:  Chinmay D Darne; Fahed Alsanea; Daniel G Robertson; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2017-06-23       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.