Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

Lifeng Yu1, Baiyu Chen1, James M Kofler1, Christopher P Favazza1, Shuai Leng1, Matthew A Kupinski2, Cynthia H McCollough1.   

Abstract

PURPOSE: Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading.
METHODS: A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at five dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models.
RESULTS: Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product-moment correlation coefficient R = 0.972, 95% confidence interval (CI): 0.919 to 0.990] and with the CHO_MS performance in the multislice viewing mode (R = 0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multislice viewing mode (R = 0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multislice and 2D modes. One reader performed better in the multislice mode (P = 0.013); whereas the other two readers showed no significant difference between the two viewing modes (P = 0.057 and P = 0.38).
CONCLUSIONS: A 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multislice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multislice viewing is used.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  channelized Hotelling observer (CHO); computed tomography (CT); image quality; model observer; multislice reading; task-based image quality assessment

Mesh:

Year:  2017        PMID: 28555878      PMCID: PMC5553707          DOI: 10.1002/mp.12380

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Visual signal detection in structured backgrounds. IV. Figures of merit for model performance in multiple-alternative forced-choice detection tasks with correlated responses.

Authors:  M P Eckstein; C K Abbey; F O Bochud
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-02       Impact factor: 2.129

2.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

3.  Channelized-ideal observer using Laguerre-Gauss channels in detection tasks involving non-Gaussian distributed lumpy backgrounds and a Gaussian signal.

Authors:  Subok Park; Harrison H Barrett; Eric Clarkson; Matthew A Kupinski; Kyle J Myers
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

4.  Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert Saunders; Craig Abbey; David Delong
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

5.  A methodology for image quality evaluation of advanced CT systems.

Authors:  Joshua M Wilson; Olav I Christianson; Samuel Richard; Ehsan Samei
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

7.  Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance.

Authors:  Ke Li; John Garrett; Yongshuai Ge; Guang-Hong Chen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

8.  A four mechanism model for threshold spatial vision.

Authors:  H R Wilson; J R Bergen
Journal:  Vision Res       Date:  1979       Impact factor: 1.886

9.  Correlation between human and model observer performance for discrimination task in CT.

Authors:  Yi Zhang; Shuai Leng; Lifeng Yu; Rickey E Carter; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2014-05-30       Impact factor: 3.609

10.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more
  18 in total

1.  Channelized Hotelling observer correlation with human observers for low-contrast detection in liver CT images.

Authors:  Alexandre Ba; Craig K Abbey; Damien Racine; Anaïs Viry; Francis R Verdun; Sabine Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-20

2.  A Web-Based Software Platform for Efficient and Quantitative CT Image Quality Assessment and Protocol Optimization.

Authors:  Mingdong Fan; Theodore Thayib; Liqiang Ren; Scott Hsieh; Cynthia McCollough; David Holmes; Lifeng Yu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

3.  Deep-learning-based model observer for a lung nodule detection task in computed tomography.

Authors:  Hao Gong; Qiyuan Hu; Andrew Walther; Chi Wan Koo; Edwin A Takahashi; David L Levin; Tucker F Johnson; Megan J Hora; Shuai Leng; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-30

4.  Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

Authors:  Christopher P Favazza; Andrea Ferrero; Lifeng Yu; Shuai Leng; Kyle L McMillan; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-03

5.  Optimization of the difference-of-Gaussian channel sets for the channelized Hotelling observer.

Authors:  Christiana Balta; Ramona W Bouwman; Mireille J M Broeders; Nico Karssemeijer; Wouter J H Veldkamp; Ioannis Sechopoulos; Ruben E van Engen
Journal:  J Med Imaging (Bellingham)       Date:  2019-09-27

6.  Rapid measurement of the low contrast detectability of CT scanners.

Authors:  Akinyinka Omigbodun; J Y Vaishnav; Scott S Hsieh
Journal:  Med Phys       Date:  2021-01-13       Impact factor: 4.071

7.  Comparison of deep learning and human observer performance for detection and characterization of simulated lesions.

Authors:  Ruben De Man; Grace J Gang; Xin Li; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2019-06-21

8.  Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT.

Authors:  Hao Gong; Lifeng Yu; Shuai Leng; Samantha Dilger; Wei Zhou; Liqiang Ren; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-07

9.  Foveated Model Observers for Visual Search in 3D Medical Images.

Authors:  Miguel A Lago; Craig K Abbey; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2021-03-02       Impact factor: 10.048

10.  Under-exploration of Three-Dimensional Images Leads to Search Errors for Small Salient Targets.

Authors:  Miguel A Lago; Aditya Jonnalagadda; Craig K Abbey; Bruno B Barufaldi; Predrag R Bakic; Andrew D A Maidment; Winifred K Leung; Susan P Weinstein; Brian S Englander; Miguel P Eckstein
Journal:  Curr Biol       Date:  2021-01-19       Impact factor: 10.834

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.