Visual signal detection in structured backgrounds. IV. Figures of merit for model performance in multiple-alternative forced-choice detection tasks with correlated responses.

M P Eckstein1, C K Abbey, F O Bochud.   

Abstract

Many investigators are currently developing models to predict human performance in detecting a signal embedded in complex backgrounds. A common figure of merit for model performance is d', an index of detectability that can be mathematically related to the proportion correct (Pc) when the responses of the model are Gaussian distributed and statistically independent. However, in many multiple-alternative forced-choice (MAFC) detection tasks, the target appears in one of M different locations within an image. If the image contains slow spatially varying luminance changes (low-pass noise), the pixel luminance values at the possible signal locations are correlated and therefore the model/human responses to the different locations might also be correlated. We investigate the effect of response correlations on model performance and compare different figures of merit for these conditions. Our results show that use of the standard d' index of detectability assuming statistical independence can lead to erroneous underestimates of Pc and misleading comparisons of models. We introduce a novel figure of merit d'(r) that takes into account response correlations and can be used to accurately estimate Pc. Furthermore, we show that d'(r) can be readily related to the standard index of detectability d' by d'(r) = d'/square root of (1 - r), where r is the correlation between the responses in any MAFC detection task. We illustrate the use of the theory by computing figures of merit for two linear models detecting a signal in one of four locations within medical image backgrounds.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  2000        PMID: 10680622     DOI: 10.1364/josaa.17.000206

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  12 in total

1.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

2.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

3.  Using 10AFC to further improve the efficiency of the quick CSF method.

Authors:  Fang Hou; Luis Lesmes; Peter Bex; Michael Dorr; Zhong-Lin Lu
Journal:  J Vis       Date:  2015       Impact factor: 2.240

4.  Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography.

Authors:  Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-22

5.  Measuring decision weights in recognition experiments with multiple response alternatives: comparing the correlation and multinomial-logistic-regression methods.

Authors:  Huanping Dai; Christophe Micheyl
Journal:  J Acoust Soc Am       Date:  2012-11       Impact factor: 1.840

6.  Non-Gaussian statistical properties of breast images.

Authors:  Craig K Abbey; Anita Nosrateih; Jascha Sohl-Dickstein; Kai Yang; John M Boone
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

7.  Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

Authors:  Lifeng Yu; Baiyu Chen; James M Kofler; Christopher P Favazza; Shuai Leng; Matthew A Kupinski; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-07-13       Impact factor: 4.071

8.  Objective assessment of image quality. V. Photon-counting detectors and list-mode data.

Authors:  Luca Caucci; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-06-01       Impact factor: 2.129

9.  Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.

Authors:  Lifeng Yu; Shuai Leng; Lingyun Chen; James M Kofler; Rickey E Carter; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  Characterizing anatomical variability in breast CT images.

Authors:  Kathrine G Metheany; Craig K Abbey; Nathan Packard; John M Boone
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.