We investigate a channelized-ideal observer (CIO) with Laguerre-Gauss (LG) channels to approximate ideal-observer performance in detection tasks involving non-Gaussian distributed lumpy backgrounds and a Gaussian signal. A Markov-chain Monte Carlo approach is employed to determine the performance of both the ideal observer and the CIO using a large number of LG channels. Our results indicate that the CIO with LG channels can approximate ideal-observer performance within error bars, depending on the imaging system, object, and channel parameters. The CIO also outperforms a channelized-Hotelling observer using the same channels. In addition, an alternative approach for estimating the CIO is investigated. This approach makes use of the characteristic functions of channelized data and employs an approximation method to the area under the receiver operating characteristic curve. The alternative approach provides good estimates of the performance of the CIO with five LG channels. However, for large channel cases, more efficient computational methods need to be developed for the CIO to become useful in practice.

Mesh:

Year:  2007        PMID: 18059906      PMCID: PMC2655642          DOI: 10.1364/josaa.24.00b136

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  11 in total

1.  Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniques.

Authors:  Matthew A Kupinski; John W Hoppin; Eric Clarkson; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

2.  Validating the use of channels to estimate the ideal linear observer.

Authors:  Brandon D Gallas; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-09       Impact factor: 2.129

3.  Ideal-observer performance under signal and background uncertainty.

Authors:  S Park; M A Kupinski; E Clarkson; H H Barrett
Journal:  Inf Process Med Imaging       Date:  2003-07

4.  Effect of random background inhomogeneity on observer detection performance.

Authors:  J P Rolland; H H Barrett
Journal:  J Opt Soc Am A       Date:  1992-05       Impact factor: 2.129

5.  A probabilistic model for the MRMC method, part 1: theoretical development.

Authors:  Eric Clarkson; Matthew A Kupinski; Harrison H Barrett
Journal:  Acad Radiol       Date:  2006-11       Impact factor: 3.173

6.  One-shot estimate of MRMC variance: AUC.

Authors:  Brandon D Gallas
Journal:  Acad Radiol       Date:  2006-03       Impact factor: 3.173

7.  Approximations to ideal-observer performance on signal-detection tasks.

Authors:  E Clarkson; H H Barrett
Journal:  Appl Opt       Date:  2000-04-10       Impact factor: 1.980

8.  Transformation of characteristic functionals through imaging systems.

Authors:  Eric Clarkson; M Kupinski; H Barrett
Journal:  Opt Express       Date:  2002-07-01       Impact factor: 3.894

9.  Objective assessment of image quality: effects of quantum noise and object variability.

Authors:  H H Barrett
Journal:  J Opt Soc Am A       Date:  1990-07       Impact factor: 2.129

10.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

View more
  16 in total

1.  Factors affecting the normality of channel outputs of channelized model observers: an investigation using realistic myocardial perfusion SPECT images.

Authors:  Fatma E A Elshahaby; Michael Ghaly; Abhinav K Jha; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-28

2.  Estimation of channelized hotelling observer performance with known class means or known difference of class means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

3.  4D numerical observer for lesion detection in respiratory-gated PET.

Authors:  Auranuch Lorsakul; Quanzheng Li; Cathryn M Trott; Christopher Hoog; Yoann Petibon; Jinsong Ouyang; Andrew F Laine; Georges El Fakhri
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

4.  Generalization Evaluation of Machine Learning Numerical Observers for Image Quality Assessment.

Authors:  Mahdi M Kalayeh; Thibault Marin; Jovan G Brankov
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

5.  Quantitative assessment of Cerenkov luminescence for radioguided brain tumor resection surgery.

Authors:  Justin S Klein; Gregory S Mitchell; Simon R Cherry
Journal:  Phys Med Biol       Date:  2017-03-13       Impact factor: 3.609

6.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

Authors:  Grace J Gang; Junghoon Lee; J Webster Stayman; Daniel J Tward; W Zbijewski; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

7.  Efficient estimation of ideal-observer performance in classification tasks involving high-dimensional complex backgrounds.

Authors:  Subok Park; Eric Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-11       Impact factor: 2.129

8.  Approximating the Ideal Observer for Joint Signal Detection and Localization Tasks by use of Supervised Learning Methods.

Authors:  Weimin Zhou; Hua Li; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

9.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Authors:  Y Petibon; J Ouyang; X Zhu; C Huang; T G Reese; S Y Chun; Q Li; G El Fakhri
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

10.  Method for optimizing channelized quadratic observers for binary classification of large-dimensional image datasets.

Authors:  M K Kupinski; E Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2015-04-01       Impact factor: 2.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.