Literature DB >> 29962647

Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT.

Hao Gong1, Lifeng Yu1, Shuai Leng1, Samantha Dilger1, Wei Zhou1, Liqiang Ren1, Cynthia H McCollough1.   

Abstract

Channelized Hotelling observer (CHO) has demonstrated strong correlation with human observer (HO) in both single-slice viewing mode and multi-slice viewing mode in low-contrast detection tasks with uniform background. However, it remains unknown if the simplest single-slice CHO in uniform background can be used to predict human observer performance in more realistic tasks that involve patient anatomical background and multi-slice viewing mode. In this study, we aim to investigate the correlation between CHO in a uniform water background and human observer performance at a multi-slice viewing mode on patient liver background for a low-contrast lesion detection task. The human observer study was performed on CT images from 7 abdominal CT exams. A noise insertion tool was employed to synthesize CT scans at two additional dose levels. A validated lesion insertion tool was used to numerically insert metastatic liver lesions of various sizes and contrasts into both phantom and patient images. We selected 12 conditions out of 72 possible experimental conditions to evaluate the correlation at various radiation doses, lesion sizes, lesion contrasts and reconstruction algorithms. CHO with both single and multi-slice viewing modes were strongly correlated with HO. The corresponding Pearson's correlation coefficient was 0.982 (with 95% confidence interval (CI) [0.936, 0.995]) and 0.989 (with 95% CI of [0.960, 0.997]) in multi-slice and single-slice viewing modes, respectively. Therefore, this study demonstrated the potential to use the simplest single-slice CHO to assess image quality for more realistic clinically relevant CT detection tasks.

Entities:  

Keywords:  Channelized Hotelling observer; Computed tomography (CT); Model observer; Multi-slice viewing; Observer study

Year:  2018        PMID: 29962647      PMCID: PMC6023415          DOI: 10.1117/12.2294955

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  12 in total

1.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs.

Authors:  J A Fessler; W L Rogers
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

2.  Channelized Hotelling observers for the assessment of volumetric imaging data sets.

Authors:  Ljiljana Platiša; Bart Goossens; Ewout Vansteenkiste; Subok Park; Brandon D Gallas; Aldo Badano; Wilfried Philips
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2011-06-01       Impact factor: 2.129

3.  Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols.

Authors:  Lifeng Yu; Maria Shiung; Dayna Jondal; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Jul-Aug       Impact factor: 1.826

4.  A methodology for image quality evaluation of advanced CT systems.

Authors:  Joshua M Wilson; Olav I Christianson; Samuel Richard; Ehsan Samei
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

5.  Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance.

Authors:  Ke Li; John Garrett; Yongshuai Ge; Guang-Hong Chen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  Lesion Insertion in Projection Domain for Computed Tomography Image Quality Assessment.

Authors:  Baiyu Chen; Zhicong Yu; Shuai Leng; Lifeng Yu; Cynthia McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

7.  Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

Authors:  Lifeng Yu; Baiyu Chen; James M Kofler; Christopher P Favazza; Shuai Leng; Matthew A Kupinski; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-07-13       Impact factor: 4.071

8.  Correlation between human and model observer performance for discrimination task in CT.

Authors:  Yi Zhang; Shuai Leng; Lifeng Yu; Rickey E Carter; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2014-05-30       Impact factor: 3.609

9.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 10.  Image quality in CT: From physical measurements to model observers.

Authors:  F R Verdun; D Racine; J G Ott; M J Tapiovaara; P Toroi; F O Bochud; W J H Veldkamp; A Schegerer; R W Bouwman; I Hernandez Giron; N W Marshall; S Edyvean
Journal:  Phys Med       Date:  2015-10-12       Impact factor: 2.685

View more
  1 in total

Review 1.  The missing link in image quality assessment in digital dental radiography.

Authors:  Kazutoshi Okamura; Kazunori Yoshiura
Journal:  Oral Radiol       Date:  2019-07-13       Impact factor: 1.852

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.