Literature DB >> 33986559

A Web-Based Software Platform for Efficient and Quantitative CT Image Quality Assessment and Protocol Optimization.

Mingdong Fan1, Theodore Thayib1, Liqiang Ren1, Scott Hsieh1, Cynthia McCollough1, David Holmes1, Lifeng Yu1.   

Abstract

Channelized Hotelling observer (CHO), which has been shown to be well correlated with human observer performance in many clinical CT tasks, has a great potential to become the method of choice for objective image quality assessment. However, the use of CHO in clinical CT is still quite limited, mainly due to its complexity in measurement and calculation in practice, and the lack of access to an efficient and validated software tool for most clinical users. In this work, a web-based software platform for CT image quality assessment and protocol optimization (CTPro) was introduced. A validated CHO tool, along with other common image quality assessment tools, was made readily accessible through this web platform for clinical users and researchers without the need of installing additional software. An example of its application to evaluation of convolutional-neural-network (CNN)-based denoising was demonstrated.

Entities:  

Keywords:  Image quality assessment; channelized Hotelling observer (CHO); protocol optimization; radiation dose reduction

Year:  2021        PMID: 33986559      PMCID: PMC8115347          DOI: 10.1117/12.2582123

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  18 in total

1.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

2.  Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels.

Authors:  Cynthia H McCollough; Lifeng Yu; James M Kofler; Shuai Leng; Yi Zhang; Zhoubo Li; Rickey E Carter
Journal:  Radiology       Date:  2015-03-26       Impact factor: 11.105

3.  Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

Authors:  Chi Ma; Lifeng Yu; Baiyu Chen; Christopher Favazza; Shuai Leng; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-05-26

4.  Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

Authors:  Christopher P Favazza; Andrea Ferrero; Lifeng Yu; Shuai Leng; Kyle L McMillan; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-03

5.  Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

Authors:  Lifeng Yu; Baiyu Chen; James M Kofler; Christopher P Favazza; Shuai Leng; Matthew A Kupinski; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-07-13       Impact factor: 4.071

6.  Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm.

Authors:  Justin Solomon; Daniele Marin; Kingshuk Roy Choudhury; Bhavik Patel; Ehsan Samei
Journal:  Radiology       Date:  2017-02-07       Impact factor: 11.105

7.  Localization of liver lesions in abdominal CT imaging: II. Mathematical model observer performance correlates with human observer performance for localization of liver lesions in abdominal CT imaging.

Authors:  Samantha K N Dilger; Shuai Leng; Baiyu Chen; Rickey E Carter; Chris P Favazza; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Phys Med Biol       Date:  2019-05-10       Impact factor: 3.609

8.  Correlation between human and model observer performance for discrimination task in CT.

Authors:  Yi Zhang; Shuai Leng; Lifeng Yu; Rickey E Carter; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2014-05-30       Impact factor: 3.609

9.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

10.  Assessing computed tomography image quality for combined detection and estimation tasks.

Authors:  Hsin-Wu Tseng; Jiahua Fan; Matthew A Kupinski
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-21
View more
  1 in total

1.  First Clinical Photon-counting Detector CT System: Technical Evaluation.

Authors:  Kishore Rajendran; Martin Petersilka; André Henning; Elisabeth R Shanblatt; Bernhard Schmidt; Thomas G Flohr; Andrea Ferrero; Francis Baffour; Felix E Diehn; Lifeng Yu; Prabhakar Rajiah; Joel G Fletcher; Shuai Leng; Cynthia H McCollough
Journal:  Radiology       Date:  2021-12-14       Impact factor: 11.105

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.