Ultra-High Spatial Resolution, Multi-Energy CT using Photon Counting Detector Technology.

S Leng1, R Gutjahr2, A Ferrero1, S Kappler3, A Henning3, A Halaweish4, W Zhou1, J Montoya1, C McCollough1.   

Abstract

Two ultra-high-resolution (UHR) imaging modes, each with two energy thresholds, were implemented on a research, whole-body photon-counting-detector (PCD) CT scanner, referred to as sharp and UHR, respectively. The UHR mode has a pixel size of 0.25 mm at iso-center for both energy thresholds, with a collimation of 32 × 0.25 mm. The sharp mode has a 0.25 mm pixel for the low-energy threshold and 0.5 mm for the high-energy threshold, with a collimation of 48 × 0.25 mm. Kidney stones with mixed mineral composition and lung nodules with different shapes were scanned using both modes, and with the standard imaging mode, referred to as macro mode (0.5 mm pixel and 32 × 0.5 mm collimation). Evaluation and comparison of the three modes focused on the ability to accurately delineate anatomic structures using the high-spatial resolution capability and the ability to quantify stone composition using the multi-energy capability. The low-energy threshold images of the sharp and UHR modes showed better shape and texture information due to the achieved higher spatial resolution, although noise was also higher. No noticeable benefit was shown in multi-energy analysis using UHR compared to standard resolution (macro mode) when standard doses were used. This was due to excessive noise in the higher resolution images. However, UHR scans at higher dose showed improvement in multi-energy analysis over macro mode with regular dose. To fully take advantage of the higher spatial resolution in multi-energy analysis, either increased radiation dose, or application of noise reduction techniques, is needed.

Entities:  

Keywords:  Computed tomography (CT); dual energy; high resolution; photon counting detector (PCD)

Year:  2017        PMID: 28392615      PMCID: PMC5384331          DOI: 10.1117/12.2255589

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  12 in total

1.  Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

Review 2.  Micro-computed tomography for analysis of urinary calculi.

Authors:  James C Williams; James A McAteer; Andrew P Evan; James E Lingeman
Journal:  Urol Res       Date:  2010-10-22

3.  Computed tomography with energy-resolved detection: a feasibility study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2008-02-19       Impact factor: 3.609

4.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

5.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

6.  Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.

Authors:  Polad M Shikhaliev; Shannon G Fritz; John W Chapman
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

7.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

8.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

Authors:  Jan S Iwanczyk; Einar Nygård; Oded Meirav; Jerry Arenson; William C Barber; Neal E Hartsough; Nail Malakhov; Jan C Wessel
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

9.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience.

Authors:  Amir Pourmorteza; Rolf Symons; Veit Sandfort; Marissa Mallek; Matthew K Fuld; Gregory Henderson; Elizabeth C Jones; Ashkan A Malayeri; Les R Folio; David A Bluemke
Journal:  Radiology       Date:  2016-02-03       Impact factor: 11.105

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more
  14 in total

1.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.

Authors:  Shuai Leng; Kishore Rajendran; Hao Gong; Wei Zhou; Ahmed F Halaweish; Andre Henning; Steffen Kappler; Matthias Baer; Joel G Fletcher; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2018-11       Impact factor: 6.016

2.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

3.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

4.  High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography.

Authors:  David J Bartlett; Chi Wan Koo; Brian J Bartholmai; Kishore Rajendran; Jayse M Weaver; Ahmed F Halaweish; Shuai Leng; Cynthia H McCollough; Joel G Fletcher
Journal:  Invest Radiol       Date:  2019-03       Impact factor: 6.016

5.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

6.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

7.  Ultra-High Resolution Photon-Counting Detector CT Reconstruction using Spectral Prior Image Constrained Compressed-Sensing (UHR-SPICCS).

Authors:  Kishore Rajendran; Shengzhen Tao; Dilbar Abdurakhimova; Shuai Leng; Cynthia McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03

8.  Impact of Photon Counting Detector Technology on kV Selection and Diagnostic Workflow in CT.

Authors:  Wei Zhou; Dilbar Abdurakhimova; Michael Bruesewitz; Ahmed Halaweish; Cynthia H McCollough; Shuai Leng
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03

9.  Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT.

Authors:  Jayasai R Rajagopal; Faraz Farhadi; Justin Solomon; Pooyan Sahbaee; Babak Saboury; William F Pritchard; Elizabeth C Jones; Ehsan Samei
Journal:  Acad Radiol       Date:  2020-08-24       Impact factor: 3.173

10.  Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment.

Authors:  Xu Ji; Ran Zhang; Guang-Hong Chen; Ke Li
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.