Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

Jan S Iwanczyk1, Einar Nygård, Oded Meirav, Jerry Arenson, William C Barber, Neal E Hartsough, Nail Malakhov, Jan C Wessel.   

Abstract

The development of an innovative detector technology for photon-counting in X-ray imaging is reported. This new generation of detectors, based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CZT) detector arrays electrically connected to application specific integrated circuits (ASICs) for readout, will produce fast and highly efficient photon-counting and energy-dispersive X-ray imaging. There are a number of applications that can greatly benefit from these novel imagers including mammography, planar radiography, and computed tomography (CT). Systems based on this new detector technology can provide compositional analysis of tissue through spectroscopic X-ray imaging, significantly improve overall image quality, and may significantly reduce X-ray dose to the patient. A very high X-ray flux is utilized in many of these applications. For example, CT scanners can produce ~100 Mphotons/mm(2)/s in the unattenuated beam. High flux is required in order to collect sufficient photon statistics in the measurement of the transmitted flux (attenuated beam) during the very short time frame of a CT scan. This high count rate combined with a need for high detection efficiency requires the development of detector structures that can provide a response signal much faster than the transit time of carriers over the whole detector thickness. We have developed CdTe and CZT detector array structures which are 3 mm thick with 16×16 pixels and a 1 mm pixel pitch. These structures, in the two different implementations presented here, utilize either a small pixel effect or a drift phenomenon. An energy resolution of 4.75% at 122 keV has been obtained with a 30 ns peaking time using discrete electronics and a (57)Co source. An output rate of 6×10(6) counts per second per individual pixel has been obtained with our ASIC readout electronics and a clinical CT X-ray tube. Additionally, the first clinical CT images, taken with several of our prototype photon-counting and energy-dispersive detector modules, are shown.

Entities:  

Year:  2009        PMID: 19920884      PMCID: PMC2777741          DOI: 10.1109/TNS.2009.2013709

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  3 in total

1.  Photon counting computed tomography: concept and initial results.

Authors:  Polad M Shikhaliev; Tong Xu; Sabee Molloi
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

2.  Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2005-12-01       Impact factor: 3.609

3.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

  3 in total
  66 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.

Authors:  Katsuyuki Taguchi; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; William C Barber
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Model predictions for the wide-angle x-ray scatter signals of healthy and malignant breast duct biopsies.

Authors:  Robert J LeClair; Andrew Ferreira; Nancy McDonald; Curtis Laamanen; Robert Y Tang
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-23

4.  Emerging Breast Imaging Technologies on the Horizon.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Semin Ultrasound CT MR       Date:  2017-09-13       Impact factor: 1.875

5.  Dimensionality and noise in energy selective x-ray imaging.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 6.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

7.  Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.

Authors:  W C Barber; J C Wessel; E Nygard; J S Iwanczyk
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-06-01       Impact factor: 1.455

8.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

9.  Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo.

Authors:  Salim Si-Mohamed; David P Cormode; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Jean-Baptiste Langlois; Lara Chalabreysse; Philippe Coulon; Ira Blevis; Ewald Roessl; Klaus Erhard; Loic Boussel; Philippe Douek
Journal:  Nanoscale       Date:  2017-11-30       Impact factor: 7.790

10.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.