Literature DB >> 31509812

Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment.

Xu Ji1, Ran Zhang, Guang-Hong Chen, Ke Li.   

Abstract

Non-contrast CT (NCCT) is widely employed as the first-line imaging test to evaluate intracranial hemorrhage (ICH). Advances in mutidetector CT (MDCT) technology have greatly improved the image quality of NCCT for the detection of established, relatively large, and acute ICHs. Meanwhile, the reliability of MDCT in detecting microbleeds and chronic hemorrhage, and in predicting hemorrhagic transformation needs to be further improved. The purpose of this work was to investigate the potential use of non-spectral photon counting CT (PCCT) to address these challenges in ICH imaging. Towards this goal, the NCCT protocol of an experimental PCCT system that simulates the geometry of a general-purpose MDCT was optimized. The optimization was driven by three imaging tasks: detection of a 4.0 mm intraparenchymal hemorrhage, detection of a 1.5 mm subarachnoid hemorrhage, and discrimination of a sulcus in the insular cortex from the parenchymal background. These imaging tasks were custom-built into an anthropomorphic head phantom. Under the guidance of the frequency-dependent noise equivalent quanta and the ideal observer model detectability index [Formula: see text], the optimal PCD detection mode, energy threshold, and reconstruction kernel were found to be the anti-charge sharing mode, 15 keV, and an apodized ramp kernel, respectively. Compared with a clinical MDCT operated with an ICH protocol and at a matched dose level, the PCCT system provided at least 20% improvements in [Formula: see text] for all three ICH imaging tasks. These results demonstrated the potential benefits of non-spectral PCCT in ICH assessment.

Entities:  

Mesh:

Year:  2019        PMID: 31509812      PMCID: PMC7301584          DOI: 10.1088/1361-6560/ab43a6

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  52 in total

1.  The Rose model, revisited.

Authors:  A E Burgess
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-03       Impact factor: 2.129

2.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Intracerebral hematomas caused by aneurysm rupture. Experience with 67 cases.

Authors:  G Nowak; D Schwachenwald; R Schwachenwald; U Kehler; H Müller; H Arnold
Journal:  Neurosurg Rev       Date:  1998       Impact factor: 3.042

4.  Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

5.  Performance of a Medipix3RX spectroscopic pixel detector with a high resistivity gallium arsenide sensor.

Authors:  Elias Hamann; Thomas Koenig; Marcus Zuber; Angelica Cecilia; Anton Tyazhev; Oleg Tolbanov; Simon Procz; Alex Fauler; Tilo Baumbach; Michael Fiederle
Journal:  IEEE Trans Med Imaging       Date:  2014-04-14       Impact factor: 10.048

6.  Task-based statistical image reconstruction for high-quality cone-beam CT.

Authors:  Hao Dang; J Webster Stayman; Jennifer Xu; Wojciech Zbijewski; Alejandro Sisniega; Michael Mow; Xiaohui Wang; David H Foos; Nafi Aygun; Vassilis E Koliatsos; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-01       Impact factor: 3.609

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  A High-Resolution Imaging Technique using a Whole-body, Research Photon Counting Detector CT System.

Authors:  S Leng; Z Yu; A Halaweish; S Kappler; K Hahn; A Henning; Z Li; J Lane; D L Levin; S Jorgensen; E Ritman; C McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-03

9.  Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment.

Authors:  A Pourmorteza; R Symons; D S Reich; M Bagheri; T E Cork; S Kappler; S Ulzheimer; D A Bluemke
Journal:  AJNR Am J Neuroradiol       Date:  2017-10-05       Impact factor: 3.825

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more
  3 in total

1.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

2.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

3.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07
  3 in total