Literature DB >> 31620547

Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Joakim da Silva1, Fredrik Grönberg1,2, Björn Cederström2, Mats Persson3, Martin Sjölin2, Zlatan Alagic4,5, Robert Bujila1,6, Mats Danielsson1,2.   

Abstract

Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype 19    lp / cm are detectable with the same clarity as 14    lp / cm on the reference scanner at equal dose and reconstruction grid, with more line pairs visible with increasing dose and decreasing image pixel size. The high spatial resolution remains evident in the anatomy of the skull phantom and is comparable to that of other photon-counting CT prototypes present in the literature. We conclude that the deep silicon-based detector used in our study could provide improved spatial resolution in patient imaging without increasing the x-ray dose.
© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  computed tomography; photon-counting; resolution; silicon

Year:  2019        PMID: 31620547      PMCID: PMC6792007          DOI: 10.1117/1.JMI.6.4.043502

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  31 in total

1.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

Authors:  Hans Bornefalk; Mats Danielsson
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

2.  Modeling the DQE(f) of photon-counting detectors: impact of the pixel sensitivity profile.

Authors:  Karl Stierstorfer; Martin Hupfer; Niko Köster
Journal:  Phys Med Biol       Date:  2019-05-10       Impact factor: 3.609

3.  Quarter-millimeter spectral coronary stent imaging with photon-counting CT: Initial experience.

Authors:  Rolf Symons; Yves De Bruecker; John Roosen; Laurent Van Camp; Tyler E Cork; Steffen Kappler; Stefan Ulzheimer; Veit Sandfort; David A Bluemke; Amir Pourmorteza
Journal:  J Cardiovasc Comput Tomogr       Date:  2018-10-15

4.  Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels: Tapping the Potential of a New Technology for Stent Imaging.

Authors:  Jochen von Spiczak; Manoj Mannil; Benjamin Peters; Tilman Hickethier; Matthias Baer; André Henning; Bernhard Schmidt; Thomas Flohr; Robert Manka; David Maintz; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2018-08       Impact factor: 6.016

5.  Digital count summing vs analog charge summing for photon counting detectors: A performance simulation study.

Authors:  Scott S Hsieh; Martin Sjolin
Journal:  Med Phys       Date:  2018-07-20       Impact factor: 4.071

6.  To bin or not to bin? The effect of CT system limiting resolution on noise and detectability.

Authors:  Jongduk Baek; Angel R Pineda; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2013-02-11       Impact factor: 3.609

7.  A framework for performance characterization of energy-resolving photon-counting detectors.

Authors:  Mats Persson; Paurakh L Rajbhandary; Norbert J Pelc
Journal:  Med Phys       Date:  2018-10-12       Impact factor: 4.071

8.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

9.  Cascaded systems analysis of charge sharing in cadmium telluride photon-counting x-ray detectors.

Authors:  Jesse Tanguay; Ian A Cunningham
Journal:  Med Phys       Date:  2018-03-31       Impact factor: 4.071

10.  Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions.

Authors:  Stephen J Glick; Clay Didier
Journal:  J Appl Phys       Date:  2013-10-10       Impact factor: 2.546

View more
  6 in total

1.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

2.  Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients.

Authors:  Francis I Baffour; Kishore Rajendran; Katrina N Glazebrook; Jamison E Thorne; Nicholas B Larson; Shuai Leng; Cynthia H McCollough; Joel G Fletcher
Journal:  Eur Radiol       Date:  2022-06-11       Impact factor: 7.034

Review 3.  Computed tomography recent history and future perspectives.

Authors:  Jiang Hsieh; Thomas Flohr
Journal:  J Med Imaging (Bellingham)       Date:  2021-08-11

4.  Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications.

Authors:  Chang-Lae Lee; Key Jo Hong; Namwoo Kim; Kwanhee Han; Dongkyu Kim; Hoe-Su Jung; Sangmin Lee; Junyoung Park; Kyoung-Yong Lee; Jee Eun Lee; Yuna Choi; Minkook Cho
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

Review 5.  Spectral Photon-Counting CT Technology in Chest Imaging.

Authors:  Salim Aymeric Si-Mohamed; Jade Miailhes; Pierre-Antoine Rodesch; Sara Boccalini; Hugo Lacombe; Valérie Leitman; Vincent Cottin; Loic Boussel; Philippe Douek
Journal:  J Clin Med       Date:  2021-12-09       Impact factor: 4.241

6.  Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience.

Authors:  Kishore Rajendran; Martin Petersilka; André Henning; Elisabeth Shanblatt; Jeffrey Marsh; Jamison Thorne; Bernhard Schmidt; Thomas Flohr; Joel Fletcher; Cynthia McCollough; Shuai Leng
Journal:  Phys Med Biol       Date:  2021-10-27       Impact factor: 3.609

  6 in total