Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.

Polad M Shikhaliev1.   

Abstract

Photon counting spectral computed tomography (PCSCT) provides material selective CT imaging at a single CT scan and fixed tube voltage. The PCSCT data are acquired in several energy ranges (bins) arranged over the x-ray spectrum. The quasi-monoenergetic CT images are acquired in these energy bins and are used for material decomposition. The PCSCT exhibits inherent limitations when material decomposition is performed using energy bins. For effective material decomposition, the energy bins used for material decomposition should be sufficiently narrow and well separated. However, when narrow bins are used, a large fraction of the detected x-ray counts is lost and statistical noise is increased. Alternatively, the x-ray spectrum can be split into a few larger bins with no gap in between and all detected x-ray photons can be used for material decomposition. However, in this case the energy bins are too wide and not well separated, which results in suboptimal material decomposition. The above contradictory requirements can be resolved if the x-ray photons are physically removed from the regions of the energy spectrum between the energy bins. Such a selective removal can be performed using filtration of the x-ray beam by high-Z filter materials with appropriate positions of K-edge energies. The K-edge filtration of x-rays can, therefore, provide necessary gaps between the energy bins with no dose penalty to the patient. In the current work, we proposed using selective K-edge filtration of x-rays in PCSCT and performed the first experimental investigation of this approach. The PCSCT system included a cadmium zinc telluride semiconductor detector with 2 × 256 pixels and 1 × 1 mm(2) pixel size, and five energy bins. The CT phantom had 14 cm diameter and included contrast elements of iodine, gold and calcifications with clinically relevant concentrations. The tube voltages of 60, 90 and 120 kVp were used. K-edge filters based on Ba (E(k) = 37.44 keV) were used for a 60 kVp tube voltage and Gd (E(k) = 50.24 keV) was used for the 90 and 120 kVp tube voltages, respectively. The material selective CT images were also acquired with conventional Al filtration for comparison. The half-value layers of x-ray beams after K-edge and Al filtration were matched. The mean entrance skin exposure was 280 mR for all tube voltages and filters. The contrast-to-noise ratio (CNR) in material-decomposed images was approximately 30%-50% higher when K-edge filters were used instead of Al filters. It was concluded that K-edge filtration of x-rays provides substantial improvement of the CNR in material-selective PCSCT. Further optimization of K-edge filter materials, tube voltages, detector technology and energy bin settings will provide even higher CNR in decomposed images.
© 2012 Institute of Physics and Engineering in Medicine

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22398007     DOI: 10.1088/0031-9155/57/6/1595

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging.

Authors:  H Ghadiri; M R Ay; M B Shiran; H Soltanian-Zadeh; H Zaidi
Journal:  Br J Radiol       Date:  2013-08-09       Impact factor: 3.039

Review 2.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

3.  Implementation of material decomposition using an EMCCD and CMOS-based micro-CT system.

Authors:  Alexander R Podgorsak; Sv Setlur Nagesh; Daniel R Bednarek; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

4.  Estimation of signal and noise for a whole-body research photon-counting CT system.

Authors:  Zhoubo Li; Shuai Leng; Zhicong Yu; Steffen Kappler; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-22

5.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

6.  Energy Window Optimization for X-Ray K-Edge Tomographic Imaging.

Authors:  Bo Meng; Wenxiang Cong; Yan Xi; Bruno De Man; Ge Wang
Journal:  IEEE Trans Biomed Eng       Date:  2015-03-18       Impact factor: 4.538

7.  Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.

Authors:  Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Shuai Leng
Journal:  Med Phys       Date:  2019-07-05       Impact factor: 4.071

8.  Deep-learning-based direct inversion for material decomposition.

Authors:  Hao Gong; Shengzhen Tao; Kishore Rajendran; Wei Zhou; Cynthia H McCollough; Shuai Leng
Journal:  Med Phys       Date:  2020-10-30       Impact factor: 4.071

9.  Use of material decomposition in the context of neurovascular intervention using standard flat panel and a high-resolution CMOS detector.

Authors:  A R Podgorsak; A C Venkataraman; S V Setlur Nagesh; D R Bednarek; S Rudin; A Siddiqui; C N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.