Literature DB >> 18612175

Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

J P Schlomka1, E Roessl, R Dorscheid, S Dill, G Martens, T Istel, C Bäumer, C Herrmann, R Steadman, G Zeitler, A Livne, R Proksa.   

Abstract

Theoretical considerations predicted the feasibility of K-edge x-ray computed tomography (CT) imaging using energy discriminating detectors with more than two energy bins. This technique enables material-specific imaging in CT, which in combination with high-Z element based contrast agents, opens up possibilities for new medical applications. In this paper, we present a CT system with energy detection capabilities, which was used to demonstrate the feasibility of quantitative K-edge CT imaging experimentally. A phantom was imaged containing PMMA, calcium-hydroxyapatite, water and two contrast agents based on iodine and gadolinium, respectively. Separate images of the attenuation by photoelectric absorption and Compton scattering were reconstructed from energy-resolved projection data using maximum-likelihood basis-component decomposition. The data analysis further enabled the display of images of the individual contrast agents and their concentrations, separated from the anatomical background. Measured concentrations of iodine and gadolinium were in good agreement with the actual concentrations. Prior to the tomographic measurements, the detector response functions for monochromatic illumination using synchrotron radiation were determined in the energy range 25 keV-60 keV. These data were used to calibrate the detector and derive a phenomenological model for the detector response and the energy bin sensitivities.

Entities:  

Mesh:

Year:  2008        PMID: 18612175     DOI: 10.1088/0031-9155/53/15/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  179 in total

1.  Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

Authors:  H-M Cho; H Ding; B P Ziemer; S Molloi
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

3.  Aberration correction for transcranial photoacoustic tomography of primates employing adjunct image data.

Authors:  Chao Huang; Liming Nie; Robert W Schoonover; Zijian Guo; Carsten O Schirra; Mark A Anastasio; Lihong V Wang
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

4.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.

Authors:  Katsuyuki Taguchi; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; William C Barber
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

5.  Computed tomography in color: NanoK-enhanced spectral CT molecular imaging.

Authors:  Dipanjan Pan; Ewald Roessl; Jens-Peter Schlomka; Shelton D Caruthers; Angana Senpan; Mike J Scott; John S Allen; Huiying Zhang; Grace Hu; Patrick J Gaffney; Eric T Choi; Volker Rasche; Samuel A Wickline; Roland Proksa; Gregory M Lanza
Journal:  Angew Chem Int Ed Engl       Date:  2010-12-10       Impact factor: 15.336

6.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

7.  Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo.

Authors:  Salim Si-Mohamed; David P Cormode; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Jean-Baptiste Langlois; Lara Chalabreysse; Philippe Coulon; Ira Blevis; Ewald Roessl; Klaus Erhard; Loic Boussel; Philippe Douek
Journal:  Nanoscale       Date:  2017-11-30       Impact factor: 7.790

8.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

9.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

10.  A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data.

Authors:  Taly Gilat Schmidt; Rina Foygel Barber; Emil Y Sidky
Journal:  IEEE Trans Med Imaging       Date:  2017-04-24       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.