Literature DB >> 31502181

The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Jing-Xin Zhao1, Xiu-Yun Su1, Zhe Zhao2, Ruo-Xiu Xiao3, Guo-Fei Sun1, Li-Cheng Zhang4, Pei-Fu Tang5.   

Abstract

The objective of this study is to investigate the synergetic effect of the pelvic rotation and X-ray offset on the radiographic anteversion/inclination (RA/RI) angles of the acetabular cup using a mathematical model. A cone model for establishing the spatial relationship between a three-dimensional (3D) circle and its two-dimensional (2D) elliptical projection is utilized to quantify the relationship between the 3D RA/RI angles of the cup and their 2D counterparts with different types of pelvic rotations in pelvic/hip anteroposterior radiographs. The results reveal that the effect of inlet/outlet views on the 2D RA angle is similar to that of iliac/obturator views. The permissible ranges of pelvic rotation for the 2D RA angle with an acceptable bias are the 3D space formed by the limits of triple axial rotations. For a specified acceptable bias of the 2D RA angle, these ranges are almost equal between pelvic and hip radiographs. The combined inlet/obturator or outlet/iliac views can maintain the 2D RA angle of a pelvic radiograph within the same range of acceptable bias as that of a hip radiograph. For a 2D RA angle with an acceptable bias, the permissible range of pelvic rotation needs to be evaluated with equal attention in both radiographs. Graphical abstract The traditional methods for calculating the radiographic angles of the acetabular cup are based on the ellipse projection of the opening circle of the cup on radiographs. However, with varying locations of the X-ray source and pelvis rotations about different axes, the outline of this ellipse projection will change, and accordingly, the traditional method and calculating results will be inaccurate. In this study, a cone model for three-dimensional circle-to-two-dimensional ellipse projection is utilized to incorporate the effect of X-ray offset and quantify the relationships of the radiographic angles of the cup with the true orientation of the cup and pelvic rotations in either pelvic or hip anteroposterior radiographic situation.

Entities:  

Keywords:  2D radiographic angle; 3D radiographic angle; Acetabular cup; Pelvic rotation; X-ray offset

Mesh:

Year:  2019        PMID: 31502181     DOI: 10.1007/s11517-019-02041-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  25 in total

1.  Pelvic tilt makes acetabular cup navigation inaccurate.

Authors:  Burkhard Lembeck; Otto Mueller; Patrik Reize; Nikolaus Wuelker
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

2.  A new technique for radiographic measurement of acetabular cup orientation.

Authors:  Brian Derbyshire; Peter J Diggle; Christopher J Ingham; Rory Macnair; James Wimhurst; Henry Wynn Jones
Journal:  J Arthroplasty       Date:  2013-07-27       Impact factor: 4.757

3.  The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty.

Authors:  Takaaki Fujishiro; Takafumi Hiranaka; Shingo Hashimoto; Shinya Hayashi; Masahiro Kurosaka; Taiki Kanno; Takeshi Masuda
Journal:  Int Orthop       Date:  2015-07-23       Impact factor: 3.075

4.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

5.  A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Ruo-Xiu Xiao; Zhe Zhao; Li-Hai Zhang; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Eng Phys       Date:  2016-10-05       Impact factor: 2.242

6.  A multiplanar radiography method for assessing cup orientation in total hip arthroplasty.

Authors:  Shahram Amiri; Bassam A Masri; Donald Garbuz; Carolyn Anglin; David R Wilson
Journal:  J Biomech Eng       Date:  2012-10       Impact factor: 2.097

7.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

8.  Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Int Orthop       Date:  2018-02-17       Impact factor: 3.075

9.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

10.  Correct Assessment of Acetabular Component Orientation in Total Hip Arthroplasty From Plane Radiographs.

Authors:  Diana Widmer; Kilian Reising; Elmar Kotter; Peter Helwig
Journal:  J Arthroplasty       Date:  2018-03-02       Impact factor: 4.757

View more
  4 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

Review 2.  Artificial intelligence and robotics: a combination that is changing the operating room.

Authors:  Iulia Andras; Elio Mazzone; Fijs W B van Leeuwen; Geert De Naeyer; Matthias N van Oosterom; Sergi Beato; Tessa Buckle; Shane O'Sullivan; Pim J van Leeuwen; Alexander Beulens; Nicolae Crisan; Frederiek D'Hondt; Peter Schatteman; Henk van Der Poel; Paolo Dell'Oglio; Alexandre Mottrie
Journal:  World J Urol       Date:  2019-11-27       Impact factor: 4.226

3.  Letter to the Editor: The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Clin Orthop Relat Res       Date:  2021-08-01       Impact factor: 4.755

4.  Reply to the Letters to the Editor: The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific.

Authors:  Thom E Snijders; Tom P C Schlösser; Marijn van Straalen; René M Castelein; Rob P Stevenson; Harrie Weinans; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2021-07-01       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.