Abstract

The purpose of this study was to compare computed tomography (CT) low-contrast detectability from human readers with observer model-based surrogates of image quality. A phantom with a range of low-contrast signals (five contrasts, three sizes) was imaged on a state-of-the-art CT scanner (Siemens' force). Images were reconstructed using filtered back projection and advanced modeled iterative reconstruction and were assessed by 11 readers using a two alternative forced choice method. Concurrently, contrast-to-noise ratio (CNR), area-weighted CNR (CNRA), and observer model-based metrics were estimated, including nonprewhitening (NPW) matched filter, NPW with eye filter (NPWE), NPW with internal noise, NPW with an eye filter and internal noise (NPWEi), channelized Hotelling observer (CHO), and CHO with internal noise (CHOi). The correlation coefficients (Pearson and Spearman), linear discriminator error, [Formula: see text], and magnitude of confidence intervals, [Formula: see text], were used to determine correlation, proper characterization of the reconstruction algorithms, and model precision, respectively. Pearson (Spearman) correlation was 0.36 (0.33), 0.83 (0.84), 0.84 (0.86), 0.86 (0.88), 0.86 (0.91), 0.88 (0.90), 0.85 (0.89), and 0.87 (0.84), [Formula: see text] was 0.25, 0.15, 0.2, 0.25, 0.3, 0.25, 0.4, and 0.45, and [Formula: see text] was [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] for CNR, CNRA, NPW, NPWE, NPWi, NPWEi, CHO, and CHOi, respectively.

Entities:  

Keywords:  computed tomography; detectability; image quality; observer models

Year:  2016        PMID: 27704032      PMCID: PMC5031789          DOI: 10.1117/1.JMI.3.3.035506

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  38 in total

1.  Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds.

Authors:  F O Bochud; C K Abbey; M P Eckstein
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-02       Impact factor: 2.129

2.  Visual signal detection in structured backgrounds. IV. Figures of merit for model performance in multiple-alternative forced-choice detection tasks with correlated responses.

Authors:  M P Eckstein; C K Abbey; F O Bochud
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-02       Impact factor: 2.129

3.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

4.  Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks.

Authors:  Miguel Eckstein; Jay Bartroff; Craig Abbey; James Whiting; Francois Bochud
Journal:  Opt Express       Date:  2003-03-10       Impact factor: 3.894

5.  Exact confidence intervals for channelized Hotelling observer performance in image quality studies.

Authors:  Adam Wunderlich; Frederic Noo; Brandon D Gallas; Marta E Heilbrun
Journal:  IEEE Trans Med Imaging       Date:  2014-09-26       Impact factor: 10.048

6.  A methodology for image quality evaluation of advanced CT systems.

Authors:  Joshua M Wilson; Olav I Christianson; Samuel Richard; Ehsan Samei
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

7.  Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE.

Authors:  Justin Solomon; Ehsan Samei
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

8.  The effect of nonlinear human visual system components on performance of a channelized Hotelling observer in structured backgrounds.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

9.  Efficiency of human visual signal discrimination.

Authors:  A E Burgess; R F Wagner; R J Jennings; H B Barlow
Journal:  Science       Date:  1981-10-02       Impact factor: 47.728

10.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more
  7 in total

1.  Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

Authors:  Christopher P Favazza; Andrea Ferrero; Lifeng Yu; Shuai Leng; Kyle L McMillan; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-03

2.  Estimating detectability index in vivo: development and validation of an automated methodology.

Authors:  Taylor Brunton Smith; Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-11

3.  Comparison of deep learning and human observer performance for detection and characterization of simulated lesions.

Authors:  Ruben De Man; Grace J Gang; Xin Li; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2019-06-21

4.  Iterative reconstruction with multifrequency signal recognition technology to improve low-contrast detectability: A phantom study.

Authors:  Yoshinori Funama; Takashi Shirasaka; Taiga Goto; Yuko Aoki; Kana Tanaka; Ryo Yoshida
Journal:  Acta Radiol Open       Date:  2022-06-17

Review 5.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11

6.  A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study.

Authors:  Wei Zhou; Gregory J Michalak; Jayse M Weaver; Hao Gong; Lifeng Yu; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2020-04       Impact factor: 10.065

7.  Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer.

Authors:  David C Rotzinger; Damien Racine; Fabio Becce; Elias Lahoud; Klaus Erhard; Salim A Si-Mohamed; Joël Greffier; Anaïs Viry; Loïc Boussel; Reto A Meuli; Yoad Yagil; Pascal Monnin; Philippe C Douek
Journal:  Diagnostics (Basel)       Date:  2021-12-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.