Literature DB >> 10680621

Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds.

F O Bochud1, C K Abbey, M P Eckstein.   

Abstract

Models of human visual detection have been successfully used in computer-generated noise. For these backgrounds, which are generally statistically stationary, model performance can be readily calculated by computing the index of detectability d' from the noise power spectrum, the signal profile, and the model template. However, model observers are ultimately needed in more real backgrounds, which may be statistically non-stationary. We investigated different methods to calculate figures of merit for model observers in real backgrounds based on different assumptions about image stationarity. We computed performance of the nonpre-whitening matched-filter observer with an eye filter on mammography and coronary angiography for an additive or a multiplicative signal. Performance was measured either by applying the model template to the images or by computing closed-form expressions with various assumptions about image stationarity. Results show first that the structured backgrounds investigated cannot be considered stationary. Second, traditional closed-form expressions of detectability calculated from the noise power spectra with the assumption of background stationarity lead to erroneous estimates of model performance. Third, the most accurate way of measuring model performances is by directly applying the model template on the images or by computing a closed-form expression that does not assume image stationarity.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  2000        PMID: 10680621     DOI: 10.1364/josaa.17.000193

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  15 in total

1.  Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniques.

Authors:  Matthew A Kupinski; John W Hoppin; Eric Clarkson; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography.

Authors:  Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-22

6.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

7.  Foveated Model Observers to predict human performance in 3D images.

Authors:  Miguel A Lago; Craig K Abbey; Miguel P Eckstein
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

8.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability.

Authors:  C K Abbey; H H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

9.  Effect of slice thickness on detectability in breast CT using a prewhitened matched filter and simulated mass lesions.

Authors:  Nathan J Packard; Craig K Abbey; Kai Yang; John M Boone
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

10.  Objective assessment of image quality. V. Photon-counting detectors and list-mode data.

Authors:  Luca Caucci; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-06-01       Impact factor: 2.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.