Literature DB >> 22692035

Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Cynthia H McCollough1, Guang Hong Chen, Willi Kalender, Shuai Leng, Ehsan Samei, Katsuyuki Taguchi, Ge Wang, Lifeng Yu, Roderic I Pettigrew.   

Abstract

This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation.

Entities:  

Mesh:

Year:  2012        PMID: 22692035      PMCID: PMC3401354          DOI: 10.1148/radiol.12112265

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  73 in total

1.  Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Authors:  Tobias F Jakobs; Christoph R Becker; Bernd Ohnesorge; Thomas Flohr; Christoph Suess; Uwe J Schoepf; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2002-02-21       Impact factor: 5.315

2.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Using human and model performance to compare MRI reconstructions.

Authors:  M Dylan Tisdall; M Stella Atkins
Journal:  IEEE Trans Med Imaging       Date:  2006-11       Impact factor: 10.048

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert Saunders; Craig Abbey; David Delong
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

6.  Effects of adaptive section collimation on patient radiation dose in multisection spiral CT.

Authors:  Paul D Deak; Oliver Langner; Michael Lell; Willi A Kalender
Journal:  Radiology       Date:  2009-07       Impact factor: 11.105

Review 7.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

8.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

9.  Human observer detection experiments with mammograms and power-law noise.

Authors:  A E Burgess; F L Jacobson; P F Judy
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

View more
  80 in total

1.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Short- and long-term effects of clinical audits on compliance with procedures in CT scanning.

Authors:  Antonio Oliveri; Nigel Howarth; Pierre Alain Gevenois; Denis Tack
Journal:  Eur Radiol       Date:  2015-11-14       Impact factor: 5.315

3.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.

Authors:  Guang-Hong Chen; Yinsheng Li
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

5.  Aortic CT angiography dose reduction: investigation of optimal noise index and iterative algorithm strength in combination with low kV.

Authors:  Osvaldo Rampado; Stefania Busso; Domenica Garabello; Ezio Marengo; Marco Valerio; Simona Capello; Simona Veglia; Ottavio Davini; Roberto Ropolo
Journal:  Radiol Med       Date:  2015-12-16       Impact factor: 3.469

6.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

Review 7.  Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review.

Authors:  Muhammed Alshamari; Eva Norrman; Mats Geijer; Kjell Jansson; Håkan Geijer
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

8.  Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities.

Authors:  Sumi Hoshiko; Daniel Smith; Cathyn Fan; Carrie R Jones; Sandra V McNeel; Ronald A Cohen
Journal:  Pediatr Radiol       Date:  2014-02-14

9.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.

Authors:  Felix G Meinel; Christian Canstein; U Joseph Schoepf; Martin Sedlmaier; Bernhard Schmidt; Brett S Harris; Thomas G Flohr; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

10.  Experimental realization of fluence field modulated CT using digital beam attenuation.

Authors:  T P Szczykutowicz; C A Mistretta
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.