Literature DB >> 29250570

Estimating detectability index in vivo: development and validation of an automated methodology.

Taylor Brunton Smith1,2,3, Justin Solomon1,2,3, Ehsan Samei1,2,3.   

Abstract

This study's purpose was to develop and validate a method to estimate patient-specific detectability indices directly from patients' CT images (i.e., in vivo). The method extracts noise power spectrum (NPS) and modulation transfer function (MTF) resolution properties from each patient's CT series based on previously validated techniques. These are combined with a reference task function (10-mm disk lesion with [Formula: see text] HU contrast) to estimate detectability indices for a nonprewhitening matched filter observer model. This method was applied to CT data from a previous study in which diagnostic performance of 16 readers was measured for the task of detecting subtle, hypoattenuating liver lesions ([Formula: see text]), using a two-alternative-forced-choice (2AFC) method, over six dose levels and two reconstruction algorithms. In vivo detectability indices were estimated and compared to the human readers' binary 2AFC outcomes using a generalized linear mixed-effects statistical model. The results of this modeling showed that the in vivo detectability indices were strongly related to 2AFC outcomes ([Formula: see text]). Linear comparison between human-detection accuracy and model-predicted detection accuracy (for like conditions) resulted in Pearson and Spearman correlation coefficients exceeding 0.84. These results suggest the potential utility of using in vivo estimates of a detectability index for an automated image quality tracking system that could be implemented clinically.

Entities:  

Keywords:  computed tomography; detectability index; image quality; observer model; patient-specific

Year:  2017        PMID: 29250570      PMCID: PMC5724743          DOI: 10.1117/1.JMI.5.3.031403

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  21 in total

1.  A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging.

Authors:  Justin Solomon; Ehsan Samei
Journal:  Phys Med Biol       Date:  2014-10-17       Impact factor: 3.609

2.  Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

Authors:  André Euler; Bram Stieltjes; Zsolt Szucs-Farkas; Reto Eichenberger; Clemens Reisinger; Anna Hirschmann; Caroline Zaehringer; Achim Kircher; Matthias Streif; Sabine Bucher; David Buergler; Luigia D'Errico; Sebastién Kopp; Markus Wilhelm; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2017-04-03       Impact factor: 5.315

3.  Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography.

Authors:  Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-22

Review 4.  Measuring the accuracy of diagnostic systems.

Authors:  J A Swets
Journal:  Science       Date:  1988-06-03       Impact factor: 47.728

5.  A prospective comparison of standard-dose CT enterography and 50% reduced-dose CT enterography with and without noise reduction for evaluating Crohn disease.

Authors:  So Jung Lee; Seong Ho Park; Ah Young Kim; Suk-Kyun Yang; Sung-Cheol Yun; Seung Soo Lee; Gyoo Sik Jung; Hyun Kwon Ha
Journal:  AJR Am J Roentgenol       Date:  2011-07       Impact factor: 3.959

6.  Automated Technique to Measure Noise in Clinical CT Examinations.

Authors:  Olav Christianson; James Winslow; Donald P Frush; Ehsan Samei
Journal:  AJR Am J Roentgenol       Date:  2015-07       Impact factor: 3.959

7.  Validation of dual-source single-tube reconstruction as a method to obtain half-dose images to evaluate radiation dose and noise reduction: phantom and human assessment using CT colonography and sinogram-affirmed iterative reconstruction (SAFIRE).

Authors:  Joel G Fletcher; Katharine L R Grant; Jeff L Fidler; Maria Shiung; Lifeng Yu; Jia Wang; Bernhard Schmidt; Thomas Allmendinger; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Sep-Oct       Impact factor: 1.826

8.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

Authors:  Grace J Gang; Junghoon Lee; J Webster Stayman; Daniel J Tward; W Zbijewski; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm.

Authors:  Justin Solomon; Daniele Marin; Kingshuk Roy Choudhury; Bhavik Patel; Ehsan Samei
Journal:  Radiology       Date:  2017-02-07       Impact factor: 11.105

10.  Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method.

Authors:  Lifeng Yu; Joel G Fletcher; Maria Shiung; Kristen B Thomas; Jane M Matsumoto; Shannon N Zingula; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2015-11       Impact factor: 3.959

View more
  6 in total

1.  Evaluation of low-contrast detectability for iterative reconstruction in pediatric abdominal computed tomography: a phantom study.

Authors:  Nicholas Rubert; Richard Southard; Susan M Hamman; Ryan Robison
Journal:  Pediatr Radiol       Date:  2019-11-09

2.  Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance.

Authors:  Davide Cester; Matthias Eberhard; Hatem Alkadhi; André Euler
Journal:  Quant Imaging Med Surg       Date:  2022-01

3.  Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases.

Authors:  Corey T Jensen; Shiva Gupta; Mohammed M Saleh; Xinming Liu; Vincenzo K Wong; Usama Salem; Wei Qiao; Ehsan Samei; Nicolaus A Wagner-Bartak
Journal:  Radiology       Date:  2022-01-11       Impact factor: 29.146

4.  Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT.

Authors:  Corey T Jensen; Nicolaus A Wagner-Bartak; Lan N Vu; Xinming Liu; Bharat Raval; David Martinez; Wei Wei; Yuan Cheng; Ehsan Samei; Shiva Gupta
Journal:  Radiology       Date:  2018-11-27       Impact factor: 11.105

5.  Variability in image quality and radiation dose within and across 97 medical facilities.

Authors:  Taylor B Smith; Shuaiqi Zhang; Alaattin Erkanli; Donald Frush; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-08

6.  Assessment of the global noise algorithm for automatic noise measurement in head CT examinations.

Authors:  Moiz Ahmad; Dominique Tan; Sujay Marisetty
Journal:  Med Phys       Date:  2021-08-19       Impact factor: 4.506

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.