Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.

CheukKai Hui1, Daniel Robertson1, Fahed Alsanea2, Sam Beddar3.   

Abstract

Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams.

Entities:  

Keywords:  liquid scintillator detector; proton beam quality assurance; proton beam range measurement

Year:  2015        PMID: 27274863      PMCID: PMC4887109          DOI: 10.1088/2057-1976/1/2/025204

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  16 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Development of an easy-to-handle range measurement tool using a plastic scintillator for proton beam therapy.

Authors:  Yasuhiro Fukushima; Minoru Hamada; Teiji Nishio; Koichi Maruyama
Journal:  Phys Med Biol       Date:  2006-10-26       Impact factor: 3.609

3.  Quality assurance of proton beams using a multilayer ionization chamber system.

Authors:  Sandeep Dhanesar; Narayan Sahoo; Matthew Kerr; M Brad Taylor; Paige Summers; X Ronald Zhu; Falk Poenisch; Michael Gillin
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

4.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

5.  Characterizing the response of miniature scintillation detectors when irradiated with proton beams.

Authors:  Louis Archambault; Jerimy C Polf; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

6.  Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston.

Authors:  Michael T Gillin; Narayan Sahoo; Martin Bues; George Ciangaru; Gabriel Sawakuchi; Falk Poenisch; Bijan Arjomandy; Craig Martin; Uwe Titt; Kazumichi Suzuki; Alfred R Smith; X Ronald Zhu
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

7.  Radiochromic film dosimetry for clinical proton beams.

Authors:  S M Vatnitsky
Journal:  Appl Radiat Isot       Date:  1997-05       Impact factor: 1.513

8.  Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy.

Authors:  W Scott Ingram; Daniel Robertson; Sam Beddar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-03-11       Impact factor: 1.455

9.  Optical artefact characterization and correction in volumetric scintillation dosimetry.

Authors:  Daniel Robertson; Cheukkai Hui; Louis Archambault; Radhe Mohan; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-12-10       Impact factor: 3.609

10.  3D reconstruction of scintillation light emission from proton pencil beams using limited viewing angles-a simulation study.

Authors:  CheukKai Hui; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-07-23       Impact factor: 3.609

View more
  4 in total

1.  Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.

Authors:  Fahed Alsanea; Chinmay Darne; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2020-04-06       Impact factor: 3.609

2.  Patient-Specific QA of Spot-Scanning Proton Beams using Radiochromic Film.

Authors:  Maria F Chan; Chin-Cheng Chen; Chengyu Shi; Jingdong Li; Xiaoli Tang; Xiang Li; Dennis Mah
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2017-05-16

3.  A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies.

Authors:  Chinmay D Darne; Daniel G Robertson; Fahed Alsanea; Charles-Antoine Collins-Fekete; Sam Beddar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2021-12-16       Impact factor: 1.455

4.  A proton imaging system using a volumetric liquid scintillator: a preliminary study.

Authors:  Chinmay D Darne; Fahed Alsanea; Daniel G Robertson; Fada Guan; Tinsu Pan; David Grosshans; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2019-07-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.