Radiochromic film dosimetry for clinical proton beams.

S M Vatnitsky1.   

Abstract

Depth doses and lateral profiles for proton beams with energies of 100-250 MeV were measured with a high-sensitivity GafChromic MD-55 film, which requires no post-irradiation development. The exposed MD-55 films were evaluated with the RIT 113 film dosimetry system. Depth doses measured with MD-55 film were compared with those obtained with a plane-parallel ionization chamber. The GafChromic film was found to be less sensitive at the distal edge for both modulated and unmodulated beams compared with an ionization chamber, however, the difference in penetration of the beam at the depth of 80-50% distal fall-off measured with this film and the ionization chamber is within 0.1-0.2 mm for studied beams. The lateral beam profiles measured with MD-55 film were in a good agreement with profiles obtained from Kodak XV-2 radiographic film, scanned with the Wellhofer densitometer. It is concluded that MD-55 film, with some limitations, is a useful detector for dosimetry measurements in a single proton beam and can be employed for verification dosimetry in multiple-beam radiation therapy.

Mesh:

Substances:

Year:  1997        PMID: 9204523     DOI: 10.1016/s0969-8043(97)00342-4

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  7 in total

1.  Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.

Authors:  CheukKai Hui; Daniel Robertson; Fahed Alsanea; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2015-07-30

2.  Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range.

Authors:  S Reinhardt; M Würl; C Greubel; N Humble; J J Wilkens; M Hillbrand; A Mairani; W Assmann; K Parodi
Journal:  Radiat Environ Biophys       Date:  2015-01-09       Impact factor: 1.925

3.  Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostate.

Authors:  Jessie Y Huang; Wayne D Newhauser; X Ronald Zhu; Andrew K Lee; Rajat J Kudchadker
Journal:  Phys Med Biol       Date:  2011-07-28       Impact factor: 3.609

4.  Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.

Authors:  Landon Wootton; Charles Holmes; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-01-15       Impact factor: 3.609

5.  Initial testing of a pixelated silicon detector prototype in proton therapy.

Authors:  Andrew J Wroe; Grant McAuley; Anthony V Teran; Jeannie Wong; Marco Petasecca; Michael Lerch; James M Slater; Anatoly B Rozenfeld
Journal:  J Appl Clin Med Phys       Date:  2017-07-18       Impact factor: 2.102

6.  Real-time dosimetry with radiochromic films.

Authors:  Pierluigi Casolaro; Luigi Campajola; Giovanni Breglio; Salvatore Buontempo; Marco Consales; Andrea Cusano; Antonello Cutolo; Francesco Di Capua; Francesco Fienga; Patrizio Vaiano
Journal:  Sci Rep       Date:  2019-03-29       Impact factor: 4.379

7.  Dose-response of deformable radiochromic dosimeters for spot scanning proton therapy.

Authors:  Simon V Jensen; Lia B Valdetaro; Per R Poulsen; Peter Balling; Jørgen B B Petersen; Ludvig P Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-11-20
  7 in total