Literature DB >> 26208304

Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.

W Scott Hoge1, Jonathan R Polimeni2.   

Abstract

PURPOSE: The purpose of this study was to seek improved image quality from accelerated echo planar imaging (EPI) data, particularly at ultrahigh fields. Certain artifacts in EPI reconstructions can be attributed to nonlinear phase differences between data acquired using frequency-encoding gradients of alternating polarity. These errors appear near regions of local susceptibility gradients and typically cannot be corrected with conventional Nyquist ghost correction (NGC) methods.
METHODS: We propose a new reconstruction method that integrates ghost correction into the parallel imaging data recovery process. This is achieved through a pair of generalized autocalibrating partially parallel acquisitions (GRAPPA) kernels that operate directly on the measured EPI data. The proposed dual-polarity GRAPPA (DPG) method estimates missing k-space data while simultaneously correcting inherent EPI phase errors.
RESULTS: Simulation results showed that standard NGC is incapable of correcting higher-order phase errors, whereas the DPG kernel approach successfully removed these errors. The presence of higher-order phase errors near regions of local susceptibility gradients was demonstrated with in vivo data. DPG reconstructions of in vivo 3T and 7T EPI data acquired near these regions showed a marked improvement over conventional methods.
CONCLUSION: This new parallel imaging method for reconstructing accelerated EPI data shows better resilience to inherent EPI phase errors, resulting in higher image quality in regions where higher-order EPI phase errors commonly occur. Magn Reson Med 76:32-44, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  GESTE; Nyquist ghost correction; artifact correction; fMRI; oblique ghosts; parallel imaging

Mesh:

Year:  2015        PMID: 26208304      PMCID: PMC4758917          DOI: 10.1002/mrm.25839

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  Real-time 3D image registration for functional MRI.

Authors:  R W Cox; A Jesmanowicz
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  Image-based ghost correction for interleaved EPI.

Authors:  M H Buonocore; D C Zhu
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

Review 5.  Accelerated parallel imaging for functional imaging of the human brain.

Authors:  Jacco A de Zwart; Peter van Gelderen; Xavier Golay; Vasiliki N Ikonomidou; Jeff H Duyn
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

6.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

7.  Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T.

Authors:  Christine Preibisch; Tim Wallenhorst; Robin Heidemann; Friedhelm E Zanella; Heinrich Lanfermann
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

8.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

9.  Reducing sensitivity losses due to respiration and motion in accelerated echo planar imaging by reordering the autocalibration data acquisition.

Authors:  Jonathan R Polimeni; Himanshu Bhat; Thomas Witzel; Thomas Benner; Thorsten Feiweier; Souheil J Inati; Ville Renvall; Keith Heberlein; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-03-23       Impact factor: 4.668

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more
  16 in total

1.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

2.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

3.  Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

Authors:  W Scott Hoge; Kawin Setsompop; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

Review 4.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

5.  Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging.

Authors:  Uten Yarach; Yi-Hang Tung; Kawin Setsompop; Myung-Ho In; Itthi Chatnuntawech; Renat Yakupov; Frank Godenschweger; Oliver Speck
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

6.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

7.  Nyquist ghost correction of breast diffusion weighted imaging using referenceless methods.

Authors:  Jessica A McKay; Steen Moeller; Lei Zhang; Edward J Auerbach; Michael T Nelson; Patrick J Bolan
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

8.  Simultaneous Motion and Distortion Correction Using Dual-Echo Diffusion-Weighted MRI.

Authors:  Onur Afacan; W Scott Hoge; Tess E Wallace; Ali Gholipour; Sila Kurugol; Simon K Warfield
Journal:  J Neuroimaging       Date:  2020-05-06       Impact factor: 2.486

9.  Dynamic distortion correction for functional MRI using FID navigators.

Authors:  Tess E Wallace; Jonathan R Polimeni; Jason P Stockmann; W Scott Hoge; Tobias Kober; Simon K Warfield; Onur Afacan
Journal:  Magn Reson Med       Date:  2020-09-24       Impact factor: 4.668

10.  Ultra-high spatial resolution BOLD fMRI in humans using combined segmented-accelerated VFA-FLEET with a recursive RF pulse design.

Authors:  Avery J L Berman; William A Grissom; Thomas Witzel; Shahin Nasr; Daniel J Park; Kawin Setsompop; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2020-07-23       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.