Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

W Scott Hoge1, Huan Tan, Robert A Kraft.   

Abstract

Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo planar imaging acquisition trajectory from frame to frame, enabling one to interleave data to remove inconsistencies that occur between sampling on positive and negative gradient readouts. With PLACE, one can coherently combine the interleaved data to cancel residual Nyquist ghosts. If the level of ghosting varies significantly from image to image, however, the signal cancellation that occurs with PLACE can adversely affect SNR-sensitive applications such as perfusion imaging with arterial spin labeling. This work proposes integrating PLACE into a PAGE-based reconstruction process to yield significantly better Nyquist ghost correction that is more robust than PLACE or PAGE alone. The robustness of this method is demonstrated in the presence of magnetic field drift with an in-vivo arterial spin labeling perfusion experiment.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20665898      PMCID: PMC3038256          DOI: 10.1002/mrm.22564

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Image-based ghost correction for interleaved EPI.

Authors:  M H Buonocore; D C Zhu
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

3.  Referenceless interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?

Authors:  Ethan K Brodsky; Alexey A Samsonov; Walter F Block
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

6.  Estimation of the noise in magnitude MR images.

Authors:  J Sijbers; A J den Dekker; J Van Audekerke; M Verhoye; D Van Dyck
Journal:  Magn Reson Imaging       Date:  1998       Impact factor: 2.546

7.  Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling.

Authors:  Y Yang; J A Frank; L Hou; F Q Ye; A C McLaughlin; J H Duyn
Journal:  Magn Reson Med       Date:  1998-05       Impact factor: 4.668

8.  Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: application to functional brain imaging.

Authors:  S G Kim; N V Tsekos
Journal:  Magn Reson Med       Date:  1997-03       Impact factor: 4.668

9.  Real-time movie imaging from a single cardiac cycle by NMR.

Authors:  B Chapman; R Turner; R J Ordidge; M Doyle; M Cawley; R Coxon; P Glover; P Mansfield
Journal:  Magn Reson Med       Date:  1987-09       Impact factor: 4.668

Review 10.  Parallel magnetic resonance imaging.

Authors:  David J Larkman; Rita G Nunes
Journal:  Phys Med Biol       Date:  2007-03-09       Impact factor: 3.609

View more
  16 in total

1.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

2.  Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

Authors:  Benedikt A Poser; Markus Barth; Pål-Erik Goa; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

3.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

Review 4.  Noise and non-neuronal contributions to the BOLD signal: applications to and insights from animal studies.

Authors:  Shella D Keilholz; Wen-Ju Pan; Jacob Billings; Maysam Nezafati; Sadia Shakil
Journal:  Neuroimage       Date:  2016-12-22       Impact factor: 6.556

5.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

6.  Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

Authors:  W Scott Hoge; Kawin Setsompop; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

7.  Improved least squares MR image reconstruction using estimates of k-space data consistency.

Authors:  Kevin M Johnson; Walter F Block; Scott B Reeder; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

8.  Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

Authors:  Julianna D Ianni; E Brian Welch; William A Grissom
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

9.  3D GRASE PROPELLER: improved image acquisition technique for arterial spin labeling perfusion imaging.

Authors:  Huan Tan; W Scott Hoge; Craig A Hamilton; Matthias Günther; Robert A Kraft
Journal:  Magn Reson Med       Date:  2011-01-19       Impact factor: 4.668

10.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.