Literature DB >> 17457876

Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Stefan Skare1, Rexford D Newbould, David B Clayton, Gregory W Albers, Scott Nagle, Roland Bammer.   

Abstract

Geometric distortions and poor image resolution are well known shortcomings of single-shot echo-planar imaging (ss-EPI). Yet, due to the motion immunity of ss-EPI, it remains the most common sequence for diffusion-weighted imaging (DWI). Moreover, both navigated DW interleaved EPI (iEPI) and parallel imaging (PI) methods, such as sensitivity encoding (SENSE) and generalized autocalibrating parallel acquisitions (GRAPPA), can improve the image quality in EPI. In this work, DW-EPI accelerated by PI is proposed as a self-calibrated and unnavigated form of interleaved acquisition. The PI calibration is performed on the b = 0 s/mm2 data and applied to each shot in the rest of the DW data set, followed by magnitude averaging. Central in this study is the comparison of GRAPPA and SENSE in the presence of off-resonances and motion. The results show that GRAPPA is more robust than SENSE against both off-resonance and motion-related artifacts. The SNR efficiency was also investigated, and it is shown that the SNR/scan time ratio is equally high for one- to three-shot high-resolution diffusion scans due to the shortened EPI readout train length. The image quality improvements without SNR efficiency loss, together with motion tolerance, make the GRAPPA-driven DW-EPI sequence clinically attractive. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17457876      PMCID: PMC3986024          DOI: 10.1002/mrm.21176

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

Authors:  W E Kyriakos; L P Panych; D F Kacher; C F Westin; S M Bao; R V Mulkern; F A Jolesz
Journal:  Magn Reson Med       Date:  2000-08       Impact factor: 4.668

2.  On the effects of gating in diffusion imaging of the brain using single shot EPI.

Authors:  S Skare; J L Andersson
Journal:  Magn Reson Imaging       Date:  2001-10       Impact factor: 2.546

3.  Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE).

Authors:  R Bammer; S L Keeling; M Augustin; K P Pruessmann; R Wolf; R Stollberger; H P Hartung; F Fazekas
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  Diffusion tensor imaging using single-shot SENSE-EPI.

Authors:  Roland Bammer; Martin Auer; Stephen L Keeling; Michael Augustin; Lara A Stables; Rupert W Prokesch; Rudolf Stollberger; Michael E Moseley; Franz Fazekas
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  SENSE-DTI at 3 T.

Authors:  T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

7.  Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo.

Authors:  T G Reese; O Heid; R M Weisskoff; V J Wedeen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

8.  Sensitivity-encoded diffusion tensor MR imaging of the cervical cord.

Authors:  Mara Cercignani; Mark A Horsfield; Federica Agosta; Massimo Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

9.  Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats.

Authors:  M E Moseley; J Kucharczyk; J Mintorovitch; Y Cohen; J Kurhanewicz; N Derugin; H Asgari; D Norman
Journal:  AJNR Am J Neuroradiol       Date:  1990-05       Impact factor: 3.825

10.  Brain abscess and necrotic brain tumor: discrimination with proton MR spectroscopy and diffusion-weighted imaging.

Authors:  Ping H Lai; Jih T Ho; Wei L Chen; Shu S Hsu; Jyh S Wang; Huay B Pan; Chien F Yang
Journal:  AJNR Am J Neuroradiol       Date:  2002-09       Impact factor: 3.825

View more
  52 in total

1.  Clinical assessment of standard and generalized autocalibrating partially parallel acquisition diffusion imaging: effects of reduction factor and spatial resolution.

Authors:  J B Andre; G Zaharchuk; N J Fischbein; M Augustin; S Skare; M Straka; J Rosenberg; M G Lansberg; S Kemp; C A C Wijman; G W Albers; N E Schwartz; R Bammer
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

2.  Reduced-distortion diffusion MRI of the craniovertebral junction.

Authors:  M Iima; A Yamamoto; V Brion; T Okada; M Kanagaki; K Togashi; D Le Bihan
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-01       Impact factor: 3.825

Review 3.  Whole-body MR imaging, bone diffusion imaging: how and why?

Authors:  Diego Jaramillo
Journal:  Pediatr Radiol       Date:  2010-04-30

4.  Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T.

Authors:  Samantha J Holdsworth; Stefan Skare; Rexford D Newbould; Raphael Guzmann; Nikolas H Blevins; Roland Bammer
Journal:  Eur J Radiol       Date:  2007-11-05       Impact factor: 3.528

Review 5.  Diffusion tensor MR imaging and fiber tractography: technical considerations.

Authors:  P Mukherjee; S W Chung; J I Berman; C P Hess; R G Henry
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-13       Impact factor: 3.825

6.  MRI of degenerative lumbar spine disease: comparison of non-accelerated and parallel imaging.

Authors:  Ingo Nölte; Lars Gerigk; Marc A Brockmann; André Kemmling; Christoph Groden
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

Review 7.  Advances in magnetic resonance neuroimaging.

Authors:  Michael E Moseley; Chunlei Liu; Sandra Rodriguez; Thomas Brosnan
Journal:  Neurol Clin       Date:  2009-02       Impact factor: 3.806

8.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

9.  Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.

Authors:  Joelle E Sarlls; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 10.  Role of Multiparametric MR Imaging in Malignancies of the Urogenital Tract.

Authors:  Alberto Diaz de Leon; Daniel Costa; Ivan Pedrosa
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-02       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.