Literature DB >> 29424460

Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

W Scott Hoge1, Kawin Setsompop2,3, Jonathan R Polimeni2,3.   

Abstract

PURPOSE: A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice-group. These navigator data may contain spatially nonlinear phase differences near regions of B0 inhomogeneity, which violates the linear model employed by most EPI ghost correction algorithms, resulting in poor reconstructions.
METHODS: Dual-Polarity GRAPPA (DPG) was previously shown to accurately model and correct both spatially nonlinear and 2D phase errors in conventional single-slice EPI data. Here, an extension we call Dual-Polarity slice-GRAPPA (DPsG) is adapted to the slice-GRAPPA method and applied to SMS-EPI data for slice separation and ghost correction concurrently-eliminating the need for a separate ghost correction step while also providing improved slice-specific EPI phase error correction.
RESULTS: Images from in vivo SMS-EPI data reconstructed using DPsG in place of conventional Nyquist ghost correction and slice-GRAPPA are presented. DPsG is shown to reduce ghosting artifacts and provide improved temporal SNR compared to the conventional reconstruction.
CONCLUSION: The proposed use of DPsG for SMS-EPI reconstruction can provide images with lower artifact levels, higher image fidelity, and improved time-series stability compared to conventional reconstruction methods.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MultiBand EPI; blipped-CAIPI; nyquist ghost correction; parallel imaging

Mesh:

Year:  2018        PMID: 29424460      PMCID: PMC6085171          DOI: 10.1002/mrm.27113

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

3.  SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.

Authors:  Franciszek Hennel; Martin Buehrer; Constantin von Deuster; Aline Seuven; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2015-08-29       Impact factor: 4.668

4.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

5.  Parallel magnetic resonance imaging using the GRAPPA operator formalism.

Authors:  Mark A Griswold; Martin Blaimer; Felix Breuer; Robin M Heidemann; Matthias Mueller; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

7.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Reducing sensitivity losses due to respiration and motion in accelerated echo planar imaging by reordering the autocalibration data acquisition.

Authors:  Jonathan R Polimeni; Himanshu Bhat; Thomas Witzel; Thomas Benner; Thorsten Feiweier; Souheil J Inati; Ville Renvall; Keith Heberlein; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-03-23       Impact factor: 4.668

9.  Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.

Authors:  W Scott Hoge; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2015-07-24       Impact factor: 4.668

10.  Two-dimensional-NGC-SENSE-GRAPPA for fast, ghosting-robust reconstruction of in-plane and slice-accelerated blipped-CAIPI echo planar imaging.

Authors:  Peter J Koopmans
Journal:  Magn Reson Med       Date:  2016-03-02       Impact factor: 4.668

View more
  5 in total

1.  Correction of respiratory artifacts in MRI head motion estimates.

Authors:  Damien A Fair; Oscar Miranda-Dominguez; Abraham Z Snyder; Anders Perrone; Eric A Earl; Andrew N Van; Jonathan M Koller; Eric Feczko; M Dylan Tisdall; Andre van der Kouwe; Rachel L Klein; Amy E Mirro; Jacqueline M Hampton; Babatunde Adeyemo; Timothy O Laumann; Caterina Gratton; Deanna J Greene; Bradley L Schlaggar; Donald J Hagler; Richard Watts; Hugh Garavan; Deanna M Barch; Joel T Nigg; Steven E Petersen; Anders M Dale; Sarah W Feldstein-Ewing; Bonnie J Nagel; Nico U F Dosenbach
Journal:  Neuroimage       Date:  2019-11-25       Impact factor: 6.556

2.  Motion-robust diffusion compartment imaging using simultaneous multi-slice acquisition.

Authors:  Bahram Marami; Benoit Scherrer; Shadab Khan; Onur Afacan; Sanjay P Prabhu; Mustafa Sahin; Simon K Warfield; Ali Gholipour
Journal:  Magn Reson Med       Date:  2018-11-16       Impact factor: 4.668

Review 3.  What's new and what's next in diffusion MRI preprocessing.

Authors:  Chantal M W Tax; Matteo Bastiani; Jelle Veraart; Eleftherios Garyfallidis; M Okan Irfanoglu
Journal:  Neuroimage       Date:  2021-12-26       Impact factor: 7.400

4.  Robust autocalibrated structured low-rank EPI ghost correction.

Authors:  Rodrigo A Lobos; W Scott Hoge; Ahsan Javed; Congyu Liao; Kawin Setsompop; Krishna S Nayak; Justin P Haldar
Journal:  Magn Reson Med       Date:  2020-12-17       Impact factor: 3.737

5.  In vivo human whole-brain Connectom diffusion MRI dataset at 760 µm isotropic resolution.

Authors:  Fuyixue Wang; Zijing Dong; Qiyuan Tian; Congyu Liao; Qiuyun Fan; W Scott Hoge; Boris Keil; Jonathan R Polimeni; Lawrence L Wald; Susie Y Huang; Kawin Setsompop
Journal:  Sci Data       Date:  2021-04-29       Impact factor: 6.444

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.