Literature DB >> 18219627

Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T.

Christine Preibisch1, Tim Wallenhorst, Robin Heidemann, Friedhelm E Zanella, Heinrich Lanfermann.   

Abstract

PURPOSE: To evaluate the parallel acquisition techniques, generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE), and determine imaging parameters maximizing sensitivity toward functional activation at 3T.
MATERIALS AND METHODS: A total of eight imaging protocols with different parallel imaging techniques (GRAPPA and mSENSE) and reduction factors (R = 1, 2, 3) were compared at different matrix sizes (64 and 128) with respect to temporal noise characteristics, artifact behavior, and sensitivity toward functional activation.
RESULTS: Echo planar imaging (EPI) with GRAPPA and a reduction factor of 2 revealed similar image quality and sensitivity than full k-space EPI. A higher incidence of artifacts and a marked sensitivity loss occurred at R = 3. Even though the same eight-channel head coil was used for signal detection in all experiments, GRAPPA generally showed more benign patterns of spatially-varying noise amplification, and mSENSE was also more susceptible to residual unfolding artifacts than GRAPPA.
CONCLUSION: At 3T and a reduction factor of 2, parallel imaging can be used with only little penalty with regard to sensitivity. With our implementation and coil setup the performance of GRAPPA was clearly superior to mSENSE. Thus, it seems advisable to pay special attention to the employed parallel imaging method and its implementation.

Mesh:

Year:  2008        PMID: 18219627     DOI: 10.1002/jmri.21191

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  A comparison of five standard methods for evaluating image intensity uniformity in partially parallel imaging MRI.

Authors:  Frank L Goerner; Timothy Duong; R Jason Stafford; Geoffrey D Clarke
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.

Authors:  W Scott Hoge; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2015-07-24       Impact factor: 4.668

3.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

4.  Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: applications for perfusion imaging in and outside the brain.

Authors:  Jack T Skinner; Ryan K Robison; Christopher P Elder; Allen T Newton; Bruce M Damon; C Chad Quarles
Journal:  Magn Reson Imaging       Date:  2014-08-29       Impact factor: 2.546

5.  BOLD fMRI using a modified HASTE sequence.

Authors:  Yongquan Ye; Yan Zhuo; Rong Xue; Xiaohong Joe Zhou
Journal:  Neuroimage       Date:  2009-07-28       Impact factor: 6.556

Review 6.  Parallel imaging artifacts in body magnetic resonance imaging.

Authors:  Patricia Noël; Roland Bammer; Caroline Reinhold; Masoom A Haider
Journal:  Can Assoc Radiol J       Date:  2009-04       Impact factor: 2.248

7.  Acceleration of Brain TOF-MRA with Compressed Sensitivity Encoding: A Multicenter Clinical Study.

Authors:  J Ding; Y Duan; Z Zhuo; Y Yuan; G Zhang; Q Song; B Gao; B Zhang; M Wang; L Yang; Y Hou; J Yuan; C Feng; J Wang; L Lin; Y Liu
Journal:  AJNR Am J Neuroradiol       Date:  2021-04-15       Impact factor: 4.966

8.  Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography.

Authors:  Donghyun Kim; Young Jin Heo; Hae Woong Jeong; Jin Wook Baek; Gi Won Shin; Sung-Chul Jin; Hye Jin Baek; Kyeong Hwa Ryu; Kang Soo Kim; InSeong Kim
Journal:  Neuroradiol J       Date:  2021-01-18
  8 in total