| Literature DB >> 25374603 |
Evandro Portela Figueirêdo1, Eder Alberto Sigua-Rodriguez2, Marcele Jardim Pimentel3, Ana Regina Oliveira Moreira3, Mauro Antônio de Arruda Nóbilo3, José Ricardo de Albergaria-Barbosa2.
Abstract
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.Entities:
Year: 2014 PMID: 25374603 PMCID: PMC4206919 DOI: 10.1155/2014/206723
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Figure 1Implants and prosthetic crowns used in the study: (a) short implant (Bicon), (b) short implant (Neodent), (c) long implant (Bicon), (d) long implant (Neodent), (e) 2-unit implant-supported fixed partial prostheses of 8 mm prosthetic crowns, and (f) 2-unit implant-supported fixed partial prostheses of 13 mm prosthetic crowns.
Study design.
| Group | Replicas | Implant characteristic | Load | Crown height (mm) |
|---|---|---|---|---|
| I | 4 | Neodent implant (long) 5 × 11 mm Titamax CM Cortical | Axial | 8 |
| 13 | ||||
| Nonaxial | 8 | |||
| 13 | ||||
|
| ||||
| II | 4 | Bicon implant (long) 5 × 11 mm | Axial | 8 |
| 13 | ||||
| Nonaxial | 8 | |||
| 13 | ||||
|
| ||||
| III | 4 | Neodent implant (short) 5 × 6 mm Titamax WS Cortical | Axial | 8 |
| 13 | ||||
| Nonaxial | 8 | |||
| 13 | ||||
|
| ||||
| IV | 4 | Bicon implant (short) 5 × 6 mm | Axial | 8 |
| 13 | ||||
| Nonaxial | 8 | |||
| 13 | ||||
Figure 2Acrylic matrix with implant.
Figure 3Representation of the points to be analyzed by Fringes software.
Three-way ANOVA for stress distribution under axial loading, based on the factors crown height, implant length, and implant system.
| Source of variation | df | Sum of squares | Mean square |
|
|
|---|---|---|---|---|---|
| Crown | 1 | 0.665 | 0.665 | 0.40 | 0.538 |
| Implant length | 1 | 15.103 | 15.103 | 9.08 | 0.003∗ |
| System | 1 | 0.195 | 0.195 | 0.12 | 0.733 |
| Crown/implant length | 1 | 6.633 | 6.633 | 3.99 | 0.047∗ |
| Crown/system | 1 | 8.726 | 8.726 | 5.25 | 0.023∗ |
| Implant length/system | 1 | 6.358 | 6.358 | 3.82 | 0.052 |
| Crown/implant length/system | 1 | 5.322 | 5.322 | 3.20 | 0.075 |
*Statistically significant difference.
Three-way ANOVA for stress distribution under nonaxial loading, based on the factors crown height, length, and implant system.
| Source of variation | df | Sum of squares | Mean square |
|
|
|---|---|---|---|---|---|
| Crown | 1 | 0.504 | 0.504 | 0.29 | 0.593 |
| Implant length | 1 | 19.309 | 19.309 | 10.94 | 0.001∗ |
| System | 1 | 1.151 | 1.151 | 0.65 | 0.420 |
| Crown/implant length | 1 | 3.715 | 3.715 | 2.11 | 0.148 |
| Crown/system | 1 | 7.859 | 7.859 | 4.45 | 0.036∗ |
| Implant length/system | 1 | 0.888 | 0.888 | 0.50 | 0.479 |
| Crown/implant length/system | 1 | 6.397 | 6.397 | 3.63 | 0.060 |
*Statistically significant difference.
Comparison of the study factors implant length and implant system relative to the crown height under axial loading in MPa.
| Factor | Variables | Prosthetic crown | |
|---|---|---|---|
| 8 mm | 13 mm | ||
| Implant length | Short | 33.4 ± 16.0 | 28.3 ± 12.2 |
| Long | 24.6 ± 12.5 | 26.8 ± 13.4 | |
|
| |||
| System | Neodent | 25.7 ± 11.4 | 31.5 ± 16.5 |
| Bicon | 26.5 ± 13.0 | 29.4 ± 13.9 | |
Note. Different uppercase letters represent statistically significant differences between implant length and between implant systems. Different lowercase letters represent differences between crown heights (Tukey's test; P < 0.05).
Comparison of the study factor implant system relative to the crown height under nonaxial loading in MPa.
| System | Prosthetic crown | |
|---|---|---|
| 8 mm | 13 mm | |
| Neodent | 31.43 ±15.44 | 28.13 ± 12.66 |
| Bicon | 26.18 ± 13.00 | 30.92 ± 14.89 |
Note. Different uppercase letters represent statistically significant differences between implant systems. Different lowercase letters represent differences between crown heights (Tukey's test; P < 0.05).