Literature DB >> 12554107

The influence of functional forces on the biomechanics of implant-supported prostheses--a review.

Saime Sahin1, Murat C Cehreli, Emine Yalçin.   

Abstract

OBJECTIVES: To evaluate published evidence related to the influence of functional forces on the biomechanics of implant-supported prostheses. DATA AND SOURCES: The literature was searched for original research articles relating control of loads on dental implants, effects of early and late occlusal loads, the influence of bone quality, prosthesis type, prosthesis material, number of supporting implants, and engineering techniques employed for evaluating mechanical and biomechanical behavior of implants using MEDLINE and manual tracing of references cited in key papers otherwise not elicited. STUDY SELECTION: Current literature on implant biomechanics as main focus and pertinent to key aspects of the review.
CONCLUSIONS: The outcome of implant treatment is often maximized when implants are placed in dense bone, number of supporting implants are increased, implant placement configuration reduces the effects of bending moments, and when a fixed prosthesis is delivered to the patient. Copyright 2002 Elsevier Science Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12554107     DOI: 10.1016/s0300-5712(02)00065-9

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  32 in total

1.  Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

Authors:  G Sannino; A Pozzi; R Schiavetti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

2.  Comparison of Stresses Around Dental Implants Placed in Normal and Fibula Reconstructed Mandibular Models using Finite Element Analysis.

Authors:  Thiyaneswaran Nesappan; Padma Ariga
Journal:  J Clin Diagn Res       Date:  2014-08-20

3.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

4.  Wear of Morse taper and external hexagon implant joints after abutment removal.

Authors:  Abraão M Prado; Jorge Pereira; Filipe S Silva; Bruno Henriques; Rubens M Nascimento; Cesar A M Benfatti; José López-López; Júlio C M Souza
Journal:  J Mater Sci Mater Med       Date:  2017-03-20       Impact factor: 3.896

5.  Synthesis of hybrid sol-gel materials and their biological evaluation with human mesenchymal stem cells.

Authors:  M Hernández-Escolano; M J Juan-Díaz; M Martínez-Ibáñez; J Suay; I Goñi; M Gurruchaga
Journal:  J Mater Sci Mater Med       Date:  2013-03-09       Impact factor: 3.896

6.  Stress on external hexagon and Morse taper implants submitted to immediate loading.

Authors:  Caroline H Odo; Marcele J Pimentel; Rafael L X Consani; Marcelo F Mesquita; Mauro A A Nóbilo
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-29

7.  Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity.

Authors:  Farhan Khalid Shah; Ashraf Gebreel; Ali Hamed Elshokouki; Ahmed Ali Habib; Amit Porwal
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

8.  Application of intra-oral dental scanners in the digital workflow of implantology.

Authors:  Wicher J van der Meer; Frank S Andriessen; Daniel Wismeijer; Yijin Ren
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

9.  Evaluation of stress distributions in peri-implant and periodontal bone tissues in 3- and 5-unit tooth and implant-supported fixed zirconia restorations by finite elements analysis.

Authors:  Sedat Guven; Koksal Beydemir; Serkan Dundar; Veysel Eratilla
Journal:  Eur J Dent       Date:  2015 Jul-Sep

10.  Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures.

Authors:  Pimduen Rungsiyakull; Kallaya Kujarearntaworn; Pathawee Khongkhunthian; Michael Swain; Chaiy Rungsiyakull
Journal:  Int J Dent       Date:  2021-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.