Literature DB >> 8359870

Treatment planning and placement of implants in the posterior maxillae: report of 732 consecutive Nobelpharma implants.

O Bahat.   

Abstract

One to nine Nobelpharma osseointegrated implants were placed in the posterior maxillae of 213 consecutive partially edentulous patients. Reconstruction was completed with a ceramic fixed partial denture with follow-up of 5 to 70 months (mean 30.3 months) after loading. Thirty-four implants in 29 patients failed; eight were replaced and one of these failed. Thus, the overall failure rate was 4.8% (35/732). The failure rate in type IV bone was only slightly higher than that in types II and III bone (5.5% versus 4.6%). The failure rate in the entire molar area was 5.3% compared with 4.5% in the premolar area (P = NS), and the failure rate of 7-mm implants was 9.5% compared with 3.8% for implants of all other lengths (P = .01).

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8359870

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

2.  Morphological analysis of the maxillary arch and hard palate in edentulous maxilla of South Indian dry skulls.

Authors:  Sekar Suresh; Govindaraj Sumathy; Mohammad Raziya Banu; Krishnaswami Kamakshi; Seppan Prakash
Journal:  Surg Radiol Anat       Date:  2012-04-01       Impact factor: 1.246

3.  A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials.

Authors:  Pham-Duong Hieu; Jin-Hyung Chung; Sung-Bin Yim; Ki-Seok Hong
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

4.  Posterior maxillary implants inserted with bicortical anchorage and placed in immediate function for partial or complete edentulous rehabilitations. A retrospective clinical study with a median follow-up of 7 years.

Authors:  Paulo Maló; Miguel de Araújo Nobre; Armando Lopes; Steven Moss
Journal:  Oral Maxillofac Surg       Date:  2014-02-28

5.  Photoelastic analysis of fixed partial prosthesis crown height and implant length on distribution of stress in two dental implant systems.

Authors:  Evandro Portela Figueirêdo; Eder Alberto Sigua-Rodriguez; Marcele Jardim Pimentel; Ana Regina Oliveira Moreira; Mauro Antônio de Arruda Nóbilo; José Ricardo de Albergaria-Barbosa
Journal:  Int J Dent       Date:  2014-10-08

6.  Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

Authors:  Ying-juan Lu; Shao-hai Chang; Jian-tao Ye; Yu-shan Ye; Yan-song Yu
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

7.  Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study.

Authors:  Ho-Chyul Han; Hyun-Chang Lim; Ji-Youn Hong; Su-Jin Ahn; Ji-Young Han; Seung-Il Shin; Jong-Hyuk Chung; Yeek Herr; Seung-Yun Shin
Journal:  J Periodontal Implant Sci       Date:  2016-08-30       Impact factor: 2.614

8.  A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis.

Authors:  Ho-Yong Song; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

9.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

10.  Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture.

Authors:  Afsheen Tabassum; Gert J Meijer; Vincent M J I Cuijpers; X Frank Walboomers
Journal:  Saudi Dent J       Date:  2020-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.