Literature DB >> 26605142

Stress on external hexagon and Morse taper implants submitted to immediate loading.

Caroline H Odo1, Marcele J Pimentel2, Rafael L X Consani3, Marcelo F Mesquita4, Mauro A A Nóbilo4.   

Abstract

BACKGROUND/AIMS: This study aimed to evaluate the stress distribution around external hexagon (EH) and Morse taper (MT) implants with different prosthetic systems of immediate loading (distal bar (DB), casting technique (CT), and laser welding (LW)) by using photoelastic method.
METHODS: Three infrastructures were manufactured on a model simulating an edentulous lower jaw. All models were composed by five implants (4.1 mm × 13.0 mm) simulating a conventional lower protocol. The samples were divided into six groups. G1: EH implants with DB and acrylic resin; G2: EH implants with titanium infrastructure CT; G3: EH implants with titanium infrastructure attached using LW; G4: MT implants with DB and acrylic resin; G5: MT implants with titanium infrastructure CT; G6: MT implants with titanium infrastructure attached using LW. After the infrastructures construction, the photoelastic models were manufactured and a loading of 4.9 N was applied in the cantilever. Five pre-determined points were analyzed by Fringes software.
RESULTS: Data showed significant differences between the connection types (p < 0.0001), and there was no significant difference among the techniques used for infrastructure.
CONCLUSION: The reduction of the stress levels was more influenced by MT connection (except for CT). Different bar types submitted to immediate loading not influenced stress concentration.

Entities:  

Keywords:  Dental casting technique; Dental implants; Dental soldering; Distal bar; Photoelastic analysis

Year:  2015        PMID: 26605142      PMCID: PMC4623216          DOI: 10.1016/j.jobcr.2015.07.002

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  29 in total

Review 1.  Strategies to achieve fit in implant prosthodontics: a review of the literature.

Authors:  A G Wee; S A Aquilino; R L Schneider
Journal:  Int J Prosthodont       Date:  1999 Mar-Apr       Impact factor: 1.681

2.  Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study.

Authors:  J Duyck; H Van Oosterwyck; J Vander Sloten; M De Cooman; R Puers; I Naert
Journal:  Clin Oral Implants Res       Date:  2000-10       Impact factor: 5.977

3.  Fatigue resistance of ITI implant-abutment connectors -- a comparison of the standard cone with a novel internally keyed design.

Authors:  Jean Perriard; W Anselm Wiskott; Aissa Mellal; Susanne S Scherrer; John Botsis; Urs C Belser
Journal:  Clin Oral Implants Res       Date:  2002-10       Impact factor: 5.977

4.  Early loading of machined-surface Brånemark implants in completely edentulous mandibles: healed bone versus fresh extraction sites.

Authors:  Hugo De Bruyn; Bruno Collaert
Journal:  Clin Implant Dent Relat Res       Date:  2002       Impact factor: 3.932

Review 5.  Immediate Occlusal Loading (IOL) of dental implants: predictable results through DIEM guidelines.

Authors:  Richard J Lazzara; Tiziano Testori; Alan Meltzer; Craig Misch; Stephan Porter; Robert del Castillo; Ronnie J Goené
Journal:  Pract Proced Aesthet Dent       Date:  2004-05

6.  Implant design and interface force transfer. A photoelastic and strain-gauge analysis.

Authors:  Murat Cehreli; Joke Duyck; Michel De Cooman; Robert Puers; Ignace Naert
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

7.  Finite element analyses of two antirotational designs of implant fixtures.

Authors:  Salih N Akour; Mohammed A Fayyad; Jamal F Nayfeh
Journal:  Implant Dent       Date:  2005-03       Impact factor: 2.454

8.  Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system.

Authors:  Tsuyoshi Kitagawa; Yasuhiro Tanimoto; Misako Odaki; Kimiya Nemoto; Masahiro Aida
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-11       Impact factor: 3.368

9.  Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks.

Authors:  N L Clelland; M C van Putten
Journal:  Int J Oral Maxillofac Implants       Date:  1997 Nov-Dec       Impact factor: 2.804

10.  Biomechanical considerations in osseointegrated prostheses.

Authors:  R Skalak
Journal:  J Prosthet Dent       Date:  1983-06       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.