Literature DB >> 20202639

Load transfer along the bone-dental implant interface.

Samira Faegh1, Sinan Müftü.   

Abstract

In this paper the variation of normal and shear stresses along a path defined on the bone-dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibular incisor and the surrounding bone. The bone and the implant are assumed to be perfectly bonded. The finite element method with 2D plane strain assumption is used to compute interfacial stresses. Highest continuous interfacial stresses are encountered in the region where the implant collar engages the cortical region, and near the apex of the implant in the subcortical region. Stress concentrations in the interfacial stresses occur near the geometric discontinuities on the implant contour, and jumps in stress values occur where the elastic modulus of the bone transitions between the cortical and trabecular bone values. Among the six contour parameters, the slope and the length of the implant collar, and the implant diameter influence the interfacial stress levels the most, and the effects of changing these parameters are significantly noticed only in the cortical bone (alveolar ridge) area. External threads cause significant stress concentrations in interfacial stresses in otherwise smoothly varying regions. This work shows that the presence of external threads could cause significant variations in both normal and shear stresses along the bone-implant interface, but not reduction in shear stress as previously thought. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Mesh:

Substances:

Year:  2010        PMID: 20202639     DOI: 10.1016/j.jbiomech.2010.02.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Photoelastic analysis of fixed partial prosthesis crown height and implant length on distribution of stress in two dental implant systems.

Authors:  Evandro Portela Figueirêdo; Eder Alberto Sigua-Rodriguez; Marcele Jardim Pimentel; Ana Regina Oliveira Moreira; Mauro Antônio de Arruda Nóbilo; José Ricardo de Albergaria-Barbosa
Journal:  Int J Dent       Date:  2014-10-08

2.  A New Model to Study Fatigue in Dental Implants Based on Probabilistic Finite Elements and Cumulative Damage Model.

Authors:  María Prados-Privado; José Antonio Bea; Rosa Rojo; Sérgio A Gehrke; José Luis Calvo-Guirado; Juan Carlos Prados-Frutos
Journal:  Appl Bionics Biomech       Date:  2017-07-05       Impact factor: 1.781

3.  Influence of Deformation and Stress between Bone and Implant from Various Bite Forces by Numerical Simulation Analysis.

Authors:  Hsin-Chung Cheng; Boe-Yu Peng; May-Show Chen; Chiung-Fang Huang; Yi Lin; Yung-Kang Shen
Journal:  Biomed Res Int       Date:  2017-05-28       Impact factor: 3.411

4.  Present and future for technologies to develop patient-specific medical devices: a systematic review approach.

Authors:  Clara-Isabel López Gualdrón; Edna-Rocío Bravo Ibarra; Andrea-Patricia Murillo Bohórquez; Israel Garnica Bohórquez
Journal:  Med Devices (Auckl)       Date:  2019-08-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.