Literature DB >> 25267438

Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine.

Fuhai Ji1, Jian Li, Neal Fleming, David Rose, Hong Liu.   

Abstract

Phenylephrine is often used to treat intra-operative hypotension. Previous studies have shown that the FloTrac cardiac monitor may overestimate cardiac output (CO) changes following phenylephrine administration. A new algorithm (4th generation) has been developed to improve performance in this setting. We performed a prospective observational study to assess the effects of phenylephrine administration on CO values measured by the 3rd and 4th generation FloTrac algorithms. 54 patients were enrolled in this study. We used the Nexfin, a pulse contour method shown to be insensitive to vasopressor administration, as the reference method. Radial arterial pressures were recorded continuously in patients undergoing surgery. Phenylephrine administration times were documented. Arterial pressure recordings were subsequently analyzed offline using three different pulse contour analysis algorithms: FloTrac 3rd generation (G3), FloTrac 4th generation (G4), and Nexfin (nf). One minute of hemodynamic measurements was analyzed immediately before phenylephrine administration and then repeated when the mean arterial pressure peaked. A total of 157 (4.6 ± 3.2 per patient, range 1-15) paired sets of hemodynamic recordings were analyzed. Phenylephrine induced a significant increase in stroke volume (SV) and CO with the FloTrac G3, but not with FloTrac G4 or Nexfin algorithms. Agreement between FloTrac G3 and Nexfin was: 0.23 ± 1.19 l/min and concordance was 51.1%. In contrast, agreement between FloTrac G4 and Nexfin was: 0.19 ± 0.86 l/min and concordance was 87.2%. In conclusion, the pulse contour method of measuring CO, as implemented in FloTrac 4th generation algorithm, has significantly improved its ability to track the changes in CO induced by phenylephrine.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25267438      PMCID: PMC4379136          DOI: 10.1007/s10877-014-9624-0

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  23 in total

1.  A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery.

Authors:  O Broch; J Renner; M Gruenewald; P Meybohm; J Schöttler; A Caliebe; M Steinfath; M Malbrain; B Bein
Journal:  Anaesthesia       Date:  2012-02-11       Impact factor: 6.955

Review 2.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

3.  Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease.

Authors:  L W J Bogert; K H Wesseling; O Schraa; E J Van Lieshout; B A J M de Mol; J van Goudoever; B E Westerhof; J J van Lieshout
Journal:  Anaesthesia       Date:  2010-09-21       Impact factor: 6.955

4.  Joint confidence region estimation for area under ROC curve and Youden index.

Authors:  Jingjing Yin; Lili Tian
Journal:  Stat Med       Date:  2013-09-30       Impact factor: 2.373

5.  Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler.

Authors:  Guo Chen; Lingzhong Meng; Brenton Alexander; Nam Phuong Tran; Zeev N Kain; Maxime Cannesson
Journal:  J Clin Anesth       Date:  2012-06       Impact factor: 9.452

Review 6.  Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision.

Authors:  Philip J Peyton; Simon W Chong
Journal:  Anesthesiology       Date:  2010-11       Impact factor: 7.892

7.  Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial.

Authors:  Jochen Mayer; Joachim Boldt; Andinet M Mengistu; Kerstin D Röhm; Stefan Suttner
Journal:  Crit Care       Date:  2010-02-15       Impact factor: 9.097

8.  Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.

Authors:  Suraphong Lorsomradee; Sratwadee Lorsomradee; Stefanie Cromheecke; Stefan G De Hert
Journal:  J Cardiothorac Vasc Anesth       Date:  2007-05-07       Impact factor: 2.628

9.  Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output.

Authors:  Serban Ion Bubenek-Turconi; Mihaela Craciun; Ion Miclea; Azriel Perel
Journal:  Anesth Analg       Date:  2013-06-11       Impact factor: 5.108

10.  Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo-derived cardiac output measurements: a prospective comparison study.

Authors:  Savvas Eleftheriadis; Zisis Galatoudis; Vasilios Didilis; Ioannis Bougioukas; Julika Schön; Hermann Heinze; Klaus-Ulrich Berger; Matthias Heringlake
Journal:  Crit Care       Date:  2009-11-09       Impact factor: 9.097

View more
  11 in total

1.  Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.

Authors:  Youn Joung Cho; Chang-Hoon Koo; Tae Kyong Kim; Deok Man Hong; Yunseok Jeon
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

Review 2.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

3.  The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system™ and the Fick method in cardiac surgery patients.

Authors:  Takuma Maeda; Eisuke Hamaguchi; Naoko Kubo; Akira Shimokawa; Hiroko Kanazawa; Yoshihiko Ohnishi
Journal:  J Clin Monit Comput       Date:  2018-11-07       Impact factor: 2.502

4.  Phenylephrine increases near-infrared spectroscopy determined muscle oxygenation in men.

Authors:  H Sørensen; J H Thomsen; A S P Meyer; D Terzic; L Hilsted; J Kjærgaard; J P Goetze; T C Barbosa; N H Secher
Journal:  J Clin Monit Comput       Date:  2016-12-16       Impact factor: 2.502

5.  Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.

Authors:  Takuma Maeda; Kohshi Hattori; Miho Sumiyoshi; Hiroko Kanazawa; Yoshihiko Ohnishi
Journal:  J Anesth       Date:  2018-04-03       Impact factor: 2.078

6.  Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass.

Authors:  Sheng-Yi Lin; An-Hsun Chou; Yung-Fong Tsai; Su-Wei Chang; Min-Wen Yang; Pei-Chi Ting; Chun-Yu Chen
Journal:  J Clin Monit Comput       Date:  2017-10-16       Impact factor: 2.502

7.  The value of a superior vena cava collapsibility index measured with a miniaturized transoesophageal monoplane continuous echocardiography probe to predict fluid responsiveness compared to stroke volume variations in open major vascular surgery: a prospective cohort study.

Authors:  Şerban-Ion Bubenek-Turconi; Adham Hendy; Sorin Băilă; Anca Drăgan; Ovidiu Chioncel; Liana Văleanu; Bianca Moroșanu; Vlad-Anton Iliescu
Journal:  J Clin Monit Comput       Date:  2019-07-05       Impact factor: 2.502

8.  Effects of dobutamine and phenylephrine on cerebral perfusion in patients undergoing cerebral bypass surgery: a randomised crossover trial.

Authors:  Annemarie Akkermans; Judith A R van Waes; Tristan P C van Doormaal; Eric E C de Waal; Gabriël J E Rinkel; Albert van der Zwan; Cor J Kalkman; Wilton A van Klei
Journal:  Br J Anaesth       Date:  2020-07-24       Impact factor: 9.166

9.  Unreliable Tracking Ability of the Third-Generation FloTrac/Vigileo™ System for Changes in Stroke Volume after Fluid Administration in Patients with High Systemic Vascular Resistance during Laparoscopic Surgery.

Authors:  Ji-Hyun Chin; Wook-Jong Kim; Jeong-Hyun Choi; Yun A Han; Seon-Ok Kim; Woo-Jong Choi
Journal:  PLoS One       Date:  2015-11-03       Impact factor: 3.240

10.  Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients.

Authors:  Bodin Khwannimit; Rattina Jomsuriya
Journal:  Turk J Med Sci       Date:  2020-04-27       Impact factor: 0.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.