Literature DB >> 17905266

Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.

Suraphong Lorsomradee1, Sratwadee Lorsomradee, Stefanie Cromheecke, Stefan G De Hert.   

Abstract

OBJECTIVE: To compare an arterial pressure-derived cardiac output (APCO) (Vigileo software version 1.07; Edwards Lifesciences, Irvine, CA) and a thermodilution cardiac output (CCO) as methods for measuring cardiac output under different pathologic and experimental conditions that induce changes in arterial waveform morphology.
DESIGN: A prospective study.
SETTING: A university hospital, single institutional. PARTICIPANTS: Fifty-two patients undergoing elective cardiac surgery.
INTERVENTIONS: Simultaneous APCO and CCO were compared in low-risk patients undergoing elective coronary artery surgery (without valvular disease) (control, n = 20), patients with aortic stenosis (AS, n = 10), aortic insufficiency (AI, n = 10), and intra-aortic balloon pump (IABP, n = 12). In the control group, additional data were registered before and after median sternotomy and phenylephrine administration.
MEASUREMENTS AND MAIN RESULTS: In the control group, Bland-Altman showed a bias of -3% (95% limits of agreement: -59% to +53%) before cardiopulmonary bypass (CPB) and of -1% (95% limits of agreement: -51% to +50%) after CPB. In the AS group, the bias was -5% (95% limits of agreement: -34% to +24%) before CPB and 1% (95% limits of agreement: -28 to +30%) after CPB. In the AI group bias was +32% (95% limits of agreement: -4% to +68%) before CPB and -2% (95% limits of agreement: -35% to +32%) after CPB. Median sternotomy decreased CCO by 10% +/- 10%, whereas it increased APCO by 56% +/- 28%. Phenylephrine administration decreased CCO by 11% +/- 16%, whereas it increased APCO by 55% +/- 34%.
CONCLUSIONS: Cardiac output measurement based on uncalibrated pulse contour analysis is able to reflect cardiac output measured with the continuous thermodilution method in patients undergoing uncomplicated coronary artery surgery. However, in situations in which the arterial pressure waveform is changed, agreement between techniques may be altered and data obtained with uncalibrated pulse contour analysis may become less reliable.

Entities:  

Mesh:

Year:  2007        PMID: 17905266     DOI: 10.1053/j.jvca.2007.02.003

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  19 in total

1.  The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

Authors:  Yohei Sotomi; Katsuomi Iwakura; Yoshiharu Higuchi; Kazuo Abe; Junko Yoshida; Takafumi Masai; Kenshi Fujii
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

2.  Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine.

Authors:  Fuhai Ji; Jian Li; Neal Fleming; David Rose; Hong Liu
Journal:  J Clin Monit Comput       Date:  2014-09-30       Impact factor: 2.502

3.  Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis.

Authors:  Lars Øivind Høiseth; Ingrid Elise Hoff; Ove Andreas Hagen; Svein Aslak Landsverk; Knut Arvid Kirkebøen
Journal:  J Clin Monit Comput       Date:  2015-02-01       Impact factor: 2.502

4.  Cardiac output monitoring in severe aortic stenosis: Which technologies are reliable?

Authors:  Martin Petzoldt; Daniel A Reuter
Journal:  J Clin Monit Comput       Date:  2015-03-26       Impact factor: 2.502

5.  General Anesthetic Management of a Patient With Hypertrophic Cardiomyopathy for Oral Surgery: Did Digitalis Contribute to Bradycardia?

Authors:  Aiji Sato Boku; Maki Morita; MinHye So; Tetsuya Tamura; Fumiaki Sano; Yasuyuki Shibuya; Jun Harada; Kazuya Sobue
Journal:  Anesth Prog       Date:  2018

6.  Lower intra-abdominal pressure has no cardiopulmonary benefits during laparoscopic colorectal surgery: a double-blind, randomized controlled trial.

Authors:  Youn Joung Cho; Hyesun Paik; Seung-Yong Jeong; Ji Won Park; Woo Young Jo; Yunseok Jeon; Kook Hyun Lee; Jeong-Hwa Seo
Journal:  Surg Endosc       Date:  2018-05-14       Impact factor: 4.584

7.  Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation.

Authors:  Koichi Suehiro; Ryu Okutani
Journal:  J Anesth       Date:  2011-07-09       Impact factor: 2.078

8.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

9.  Impact of changes in systemic vascular resistance on a novel non-invasive continuous cardiac output measurement system based on pulse wave transit time: a report of two cases.

Authors:  Hironori Ishihara; Masato Tsutsui
Journal:  J Clin Monit Comput       Date:  2013-11-07       Impact factor: 2.502

10.  Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  Intensive Care Med       Date:  2013-01-04       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.