Literature DB >> 29039063

Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass.

Sheng-Yi Lin1, An-Hsun Chou1, Yung-Fong Tsai1,2, Su-Wei Chang3,4, Min-Wen Yang1, Pei-Chi Ting1, Chun-Yu Chen5,6.   

Abstract

The FloTrac system is a system for cardiac output (CO) measurement that is less invasive than the pulmonary artery catheter (PAC). The purposes of this study were to (1) compare the level of agreement and trending abilities of CO values measured using the fourth version of the FloTrac system (CCO-FloTrac) and PAC-originated continuous thermodilution (CCO-PAC) and (2) analyze the inadequate CO-discriminating ability of the FloTrac system before and after cardiopulmonary bypass (CPB). Fifty patients were included. After exclusion, 32 patients undergoing cardiac surgery with CPB were analyzed. All patients were monitored with a PAC and radial artery catheter connected to the FloTrac system. CO was assessed at 10 timing points during the surgery. In the Bland-Altman analysis, the percentage errors (bias, the limits of agreement) of the CCO-FloTrac were 61.82% (0.16, - 2.15 to 2.47 L min) and 51.80% (0.48, - 1.97 to 2.94 L min) before and after CPB, respectively, compared with CCO-PAC. The concordance rates in the four-quadrant plot were 64.10 and 62.16% and the angular concordance rates (angular mean bias, the radial limits of agreement) in the polar-plot analysis were 30.00% (17.62°, - 70.69° to 105.93°) and 38.63% (- 10.04°, - 96.73° to 76.30°) before and after CPB, respectively. The area under the receiver operating characteristic curve for CCO-FloTrac was 0.56, 0.52, 0.52, and 0.72 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% CO changes (ΔCO) of CCO-PAC before CPB, respectively, and 0.59, 0.55, 0.49, and 0.46 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% ΔCO of CCO-PAC after CPB, respectively. When CO < 4 L/min was considered inadequate, the Cohen κ coefficient was 0.355 and 0.373 before and after CPB, respectively. The accuracy, trending ability, and inadequate CO-discriminating ability of the fourth version of the FloTrac system in CO monitoring are not statistically acceptable in cardiac surgery.

Entities:  

Keywords:  Arterial waveform analysis; Cardiac output; Cardiopulmonary bypass; Cohen κ coefficient; FloTrac

Mesh:

Year:  2017        PMID: 29039063     DOI: 10.1007/s10877-017-0071-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  58 in total

1.  A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.

Authors:  James Dean Sandham; Russell Douglas Hull; Rollin Frederick Brant; Linda Knox; Graham Frederick Pineo; Christopher J Doig; Denny P Laporta; Sidney Viner; Louise Passerini; Hugh Devitt; Ann Kirby; Michael Jacka
Journal:  N Engl J Med       Date:  2003-01-02       Impact factor: 91.245

Review 2.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

3.  Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.

Authors:  Youn Joung Cho; Chang-Hoon Koo; Tae Kyong Kim; Deok Man Hong; Yunseok Jeon
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

4.  Platelet and neutrophil activation during cardiac surgical procedures: impact of cardiopulmonary bypass.

Authors:  D S Morse; D Adams; B Magnani
Journal:  Ann Thorac Surg       Date:  1998-03       Impact factor: 4.330

5.  Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass.

Authors:  T Baba; T Goto; A Yoshitake; Y Shibata
Journal:  Anesth Analg       Date:  1997-08       Impact factor: 5.108

6.  Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.

Authors:  Cornelis Slagt; Marcel A de Leeuw; Jan Beute; Emmy Rijnsburger; Martijn Hoeksema; Jan W R Mulder; Ignacio Malagon; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-15       Impact factor: 2.502

7.  Disagreement between fourth generation FloTrac and LiDCOrapid measurements of cardiac output and stroke volume variation during laparoscopic colectomy.

Authors:  Masato Nakasuji; Aki Okutani; Taeko Miyata; Norie Imanaka; Masuji Tanaka; Kae Nakasuji; Miwako Nagai
Journal:  J Clin Anesth       Date:  2016-08-17       Impact factor: 9.452

8.  Propofol sedation after open heart surgery. A clinical and pharmacokinetic study.

Authors:  T J McMurray; P S Collier; I W Carson; S M Lyons; P Elliott
Journal:  Anaesthesia       Date:  1990-04       Impact factor: 6.955

9.  Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery.

Authors:  Tong J Gan; Andrew Soppitt; Mohamed Maroof; Habib el-Moalem; Kerri M Robertson; Eugene Moretti; Peter Dwane; Peter S A Glass
Journal:  Anesthesiology       Date:  2002-10       Impact factor: 7.892

Review 10.  An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man.

Authors:  M Karamanoglu; M F O'Rourke; A P Avolio; R P Kelly
Journal:  Eur Heart J       Date:  1993-02       Impact factor: 29.983

View more
  6 in total

1.  The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system™ and the Fick method in cardiac surgery patients.

Authors:  Takuma Maeda; Eisuke Hamaguchi; Naoko Kubo; Akira Shimokawa; Hiroko Kanazawa; Yoshihiko Ohnishi
Journal:  J Clin Monit Comput       Date:  2018-11-07       Impact factor: 2.502

2.  Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation.

Authors:  Yutaka Murata; Takumi Imai; Chikashi Takeda; Toshiyuki Mizota; Shuji Kawamoto
Journal:  Sci Rep       Date:  2022-07-01       Impact factor: 4.996

3.  Efficacy of early goal-directed therapy using FloTrac/EV1000 to improve postoperative outcomes in patients undergoing off-pump coronary artery bypass surgery: a randomized controlled trial.

Authors:  Sirirat Tribuddharat; Thepakorn Sathitkarnmanee; Kriangsak Ngamsaengsirisup; Sanpicha Sornpirom
Journal:  J Cardiothorac Surg       Date:  2022-08-21       Impact factor: 1.522

4.  Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference.

Authors:  Ramakrishna Mukkamala; Benjamin A Kohl; Aman Mahajan
Journal:  BMC Anesthesiol       Date:  2021-07-10       Impact factor: 2.217

5.  Efficacy of Intraoperative Hemodynamic Optimization Using FloTrac/EV1000 Platform for Early Goal-Directed Therapy to Improve Postoperative Outcomes in Patients Undergoing Coronary Artery Bypass Graft with Cardiopulmonary Bypass: A Randomized Controlled Trial.

Authors:  Sirirat Tribuddharat; Thepakorn Sathitkarnmanee; Kriangsak Ngamsangsirisup; Krisana Nongnuang
Journal:  Med Devices (Auckl)       Date:  2021-06-28

6.  Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients.

Authors:  Bodin Khwannimit; Rattina Jomsuriya
Journal:  Turk J Med Sci       Date:  2020-04-27       Impact factor: 0.973

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.