Literature DB >> 20860647

Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease.

L W J Bogert1, K H Wesseling, O Schraa, E J Van Lieshout, B A J M de Mol, J van Goudoever, B E Westerhof, J J van Lieshout.   

Abstract

Pulse contour methods determine cardiac output semi-invasively using standard arterial access. This study assessed whether cardiac output can be determined non-invasively by replacing the intra-arterial pressure input with a non-invasive finger arterial pressure input in two methods, Nexfin CO-trek and Modelflow , in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO-trek were 0.22 (0.77) and 0.44 (0.81) l.min(-1) , for intra-arterial and non-invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min(-1) , respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO-trek were 0.16 (0.78) and 0.34 (0.83), for intra-arterial and non-invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min(-1) , respectively. Thus, Nexfin CO-trek readings were not different from thermodilution cardiac output, for both invasive and non-invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non-invasive arterial pressure input.
© 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2010        PMID: 20860647     DOI: 10.1111/j.1365-2044.2010.06511.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  56 in total

1.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

Review 2.  [Management of patients with pulmonary hypertension].

Authors:  B Preckel; S Eberl; J Fräßdorf; M W Hollmann
Journal:  Anaesthesist       Date:  2012-07       Impact factor: 1.041

3.  Intravenous Hydration for Management of Medication-Resistant Orthostatic Intolerance in the Adolescent and Young Adult.

Authors:  Jeffrey P Moak; Derek Leong; Robin Fabian; Vicki Freedenberg; Elizabeth Jarosz; Carol Toney; Sridhar Hanumanthaiah; Anil Darbari
Journal:  Pediatr Cardiol       Date:  2015-10-07       Impact factor: 1.655

4.  Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine.

Authors:  Fuhai Ji; Jian Li; Neal Fleming; David Rose; Hong Liu
Journal:  J Clin Monit Comput       Date:  2014-09-30       Impact factor: 2.502

Review 5.  Smartphone Applications for Hypertension Management: a Potential Game-Changer That Needs More Control.

Authors:  Gianfranco Parati; Camilla Torlasco; Stefano Omboni; Dario Pellegrini
Journal:  Curr Hypertens Rep       Date:  2017-06       Impact factor: 5.369

Review 6.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

7.  Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

Authors:  Guo Chen; Elena Chung; Lingzhong Meng; Brenton Alexander; Trung Vu; Joseph Rinehart; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-03-01       Impact factor: 2.502

8.  Systemic hemodynamics during orthostasis in multiple system atrophy.

Authors:  David S Goldstein; Cathy Sims-O'Neil
Journal:  Parkinsonism Relat Disord       Date:  2016-02-10       Impact factor: 4.891

9.  Relationship between sympathetic nerve activity and aortic wave reflection characteristics in postmenopausal women.

Authors:  Emma C Hart; Nisha Charkoudian; Michael J Joyner; Jill N Barnes; Timothy B Curry; Darren P Casey
Journal:  Menopause       Date:  2013-09       Impact factor: 2.953

10.  Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

Authors:  Christopher G Scully; Shanti Gomatam; Shawn Forrest; David G Strauss
Journal:  J Clin Monit Comput       Date:  2015-08-19       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.