Literature DB >> 25212705

The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation.

Koichi Suehiro1, Katsuaki Tanaka, Tokuhiro Yamada, Tadashi Matsuura, Takashi Mori, Tomoharu Funao, Kiyonobu Nishikawa.   

Abstract

This study was aimed at comparing the cardiac output (CO) measured by the Vigileo™-FloTrac™ system with that estimated by the thermodilution pulmonary artery catheter (PAC) during one-lung ventilation (OLV) and determining the reliability of this system in tracking phenylephrine-induced CO changes during OLV. Sixteen patients scheduled for descending aorta replacement were enrolled. The study was performed 30 min after starting OLV under stable hemodynamic conditions. We recorded hemodynamic variables, CO measured by PAC thermodilution (ICO), CO measured by Vigileo™-FloTrac™ system (Version 3.02, Edwards Lifesciences, Irvine, CA, USA) (APCO), and systemic vascular resistance index (SVRI) before (T0) and after (T1) phenylephrine (100 μg) administration. We used Bland-Altman analysis to compare ICO and APCO. Polar plot and four-quadrant plot were used to assess the tracking ability of the Vigileo™-FloTrac™ system against ICO after administration of phenylephrine. Ninety hemodynamic interventions were performed. Bland-Altman analysis revealed that the mean bias between APCO and ICO was 0.05 L/min and the percentage error, 46.9 %. Four-quadrant plot analysis showed a concordance rate of 24.7 %, while polar plot analysis showed that the concordance rate was 13.3 %; the angular bias, -45.9°; radial limit of agreement, 85.3°. The bias between APCO and ICO was significantly correlated with the SVRI value (p < 0.001, r(2) = 0.822). The reliability of the Vigileo™-FloTrac™ system during OLV to estimate CO and track phenylephrine-induced CO changes was not acceptable.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25212705     DOI: 10.1007/s10877-014-9609-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  22 in total

Review 1.  Practice guidelines for pulmonary artery catheterization: an updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization.

Authors: 
Journal:  Anesthesiology       Date:  2003-10       Impact factor: 7.892

2.  Effects of one-lung ventilation on thermodilution-derived assessment of cardiac output.

Authors:  C Trepte; S Haas; N Meyer; M Gebhardt; M S Goepfert; A E Goetz; D A Reuter
Journal:  Br J Anaesth       Date:  2012-03-22       Impact factor: 9.166

Review 3.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

4.  The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

Authors:  Yohei Sotomi; Katsuomi Iwakura; Yoshiharu Higuchi; Kazuo Abe; Junko Yoshida; Takafumi Masai; Kenshi Fujii
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

5.  Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery.

Authors:  M Biais; O Bernard; J C Ha; C Degryse; F Sztark
Journal:  Br J Anaesth       Date:  2010-02-26       Impact factor: 9.166

6.  Effects of lung surgery and one-lung ventilation on pulmonary arterial pressure, venous admixture and immediate postoperative lung function.

Authors:  G Malmkvist; R Fletcher; L Nordström; O Werner
Journal:  Br J Anaesth       Date:  1989-12       Impact factor: 9.166

7.  Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.

Authors:  Cornelis Slagt; Marcel A de Leeuw; Jan Beute; Emmy Rijnsburger; Martijn Hoeksema; Jan W R Mulder; Ignacio Malagon; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-15       Impact factor: 2.502

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation.

Authors:  M Biais; K Nouette-Gaulain; V Cottenceau; P Revel; F Sztark
Journal:  Br J Anaesth       Date:  2008-10-12       Impact factor: 9.166

10.  Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.

Authors:  D Lahner; B Kabon; C Marschalek; A Chiari; G Pestel; A Kaider; E Fleischmann; H Hetz
Journal:  Br J Anaesth       Date:  2009-07-23       Impact factor: 9.166

View more
  6 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2018-09-28       Impact factor: 2.078

3.  Hemodynamic monitoring and management in high-risk surgery: a survey among Japanese anesthesiologists.

Authors:  Koichi Suehiro; Katsuaki Tanaka; Akira Mukai; Alexandre Joosten; Olivier Desebbe; Brenton Alexander; Maxime Cannesson; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

4.  Impact of continuous non-invasive blood pressure monitoring on hemodynamic fluctuation during general anesthesia: a randomized controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Clin Monit Comput       Date:  2018-03-06       Impact factor: 2.502

5.  Pre-anesthetic stroke volume variation can predict cardiac output decrease and hypotension during induction of general anesthesia.

Authors:  Takashi Juri; Koichi Suehiro; Sayaka Tsujimoto; Shigemune Kuwata; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Clin Monit Comput       Date:  2017-06-24       Impact factor: 2.502

Review 6.  Hypoxemia During One-Lung Ventilation: Does It Really Matter?

Authors:  Chris Durkin; Kali Romano; Sinead Egan; Jens Lohser
Journal:  Curr Anesthesiol Rep       Date:  2021-07-07
  6 in total