Literature DB >> 19628484

Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.

D Lahner1, B Kabon, C Marschalek, A Chiari, G Pestel, A Kaider, E Fleischmann, H Hetz.   

Abstract

BACKGROUND: Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fluid responsiveness as measured by the oesophageal Doppler.
METHODS: Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to <350 ms. Patients were connected to a monitoring device, obtaining SVV by APCO. Haemodynamic variables were recorded before and after fluid bolus application. Fluid responsiveness was defined as an increase in stroke volume index >10%. The ability of SVV to predict fluid responsiveness was assessed by calculation of the area under the receiver operating characteristic (ROC) curve.
RESULTS: Twenty patients received 67 fluid boluses. Fifty-two of the 67 fluid boluses administered resulted in fluid responsiveness. SVV achieved an area under the ROC curve of 0.512 [confidence interval (CI) 0.32-0.70]. A cut-off point for fluid responsiveness was found for SVV > or =8.5% (sensitivity: 77%; specificity: 43%; positive predictive value: 84%; and negative predictive value: 33%).
CONCLUSIONS: This prospective, interventional observer-blinded study demonstrates that SVV obtained by APCO, using the FloTrac/Vigileo system, is not a reliable predictor of fluid responsiveness in the setting of major abdominal surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19628484     DOI: 10.1093/bja/aep200

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  22 in total

1.  Visual estimation of pulse pressure variation is not reliable: a randomized simulation study.

Authors:  Joseph Rinehart; Tanzeem Islam; Rob Boud; Allison Nguyen; Brenton Alexander; Cecilia Canales; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-04-11       Impact factor: 2.502

2.  What is your strategy for fluid management?

Authors:  Young-Cheol Woo
Journal:  Korean J Anesthesiol       Date:  2012-04-23

3.  The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation.

Authors:  Koichi Suehiro; Katsuaki Tanaka; Tokuhiro Yamada; Tadashi Matsuura; Takashi Mori; Tomoharu Funao; Kiyonobu Nishikawa
Journal:  J Clin Monit Comput       Date:  2014-09-12       Impact factor: 2.502

4.  Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.

Authors:  Marko Zlicar; Vesna Novak-Jankovic; Rok Blagus; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2017-11-17       Impact factor: 2.502

5.  Hemodynamic effects of orally administered delta-ALA during radical prostatectomy.

Authors:  Volker Eichhorn; Alexander Maerz; Georg Salomon; Irmgard F Blanc; Daniel A Reuter; Alwin E Goetz
Journal:  World J Urol       Date:  2011-11-26       Impact factor: 4.226

Review 6.  Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis.

Authors:  Zhongheng Zhang; Baolong Lu; Xiaoyan Sheng; Ni Jin
Journal:  J Anesth       Date:  2011-09-04       Impact factor: 2.078

7.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

8.  Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study.

Authors:  Jan Benes; Ivan Chytra; Pavel Altmann; Marek Hluchy; Eduard Kasal; Roman Svitak; Richard Pradl; Martin Stepan
Journal:  Crit Care       Date:  2010-06-16       Impact factor: 9.097

9.  Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice.

Authors:  Feng Zhao; Peng Wang; Shujun Pei; Weidong Mi; Qiang Fu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

10.  Intraoperative fluid management in open gastrointestinal surgery: goal-directed versus restrictive.

Authors:  Jun Zhang; Hui Qiao; Zhiyong He; Yun Wang; Xuehua Che; Weimin Liang
Journal:  Clinics (Sao Paulo)       Date:  2012-10       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.