BACKGROUND: Stroke volume variation (SVV) is able to predict adequately the individual response to fluid loading. Our objective was to assess whether the SVV measured by a new algorithm (Vigileo; Flotrac) can predict fluid responsiveness.
METHODS: Forty mechanically ventilated patients undergoing liver transplantation, who needed volume expansion (VE), were included. VE was done with albumin (4%) 20 mlxBMI over 20 min. SVV, pulse pressure variation (PPV), central venous pressure (CVP), and pulmonary artery occlusion pressure (PAOP) were measured immediately before and after VE. Cardiac output (CO) measured by transthoracic echocardiography (CO-TTE) was used to define responder patients if CO increased by 15% or more after VE, or non-responder otherwise. CO obtained with the pulmonary artery catheter (CO-PAC) and with Vigileo (CO-Vigileo) were also recorded.
RESULTS: Five patients were excluded. Seventeen patients were responders (Rs) and 18 were non-responders (NRs). Before VE (i) SVV and PPV were higher in Rs and (ii) CVP and PAOP were lower in Rs. Baseline SVV and PPV correlated with change in CO induced by VE (respectively, r(2)=0.72, P<0.0001; r(2)=0.84, P<0.0001). An SVV threshold of >10% discriminated Rs with a sensitivity of 94% and a specificity of 94%. After VE, the decrease in SVV was significantly correlated with the increase in CO (r(2)=0.51; P<0.0001). There was no difference between the area under the ROC curves of SVV and PPV. After VE, the change in CO-Vigileo was closely correlated with change in CO-TTE (r(2)=0.74, P<0.0001) and with change in CO-PAC (r(2)=0.77, P<0.0001).
CONCLUSIONS: The SVV obtained by the Vigileo system may be used as a predictor of fluid responsiveness in patients with circulatory failure after liver transplantation. CO-Vigileo is able to track the change in CO induced by VE.

Entities:  

Mesh:

Year:  2008        PMID: 18852114     DOI: 10.1093/bja/aen277

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  42 in total

Review 1.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

Review 2.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

3.  Does intravenous landiolol, a β1-adrenergic blocker, affect stroke volume variation?

Authors:  Zen'ichiro Wajima; Toshiya Shiga; Kazuyuki Imanaga; Tetsuo Inoue
Journal:  J Anesth       Date:  2013-05-08       Impact factor: 2.078

4.  Stroke volume variation obtained with Vigileo/FloTrac™ system during bleeding and fluid overload in dogs.

Authors:  Hiroyuki Taguchi; Keisuke Ichinose; Hironari Tanimoto; Michiko Sugita; Masafumi Tashiro; Tatsuo Yamamoto
Journal:  J Anesth       Date:  2011-06-04       Impact factor: 2.078

5.  Validity of Pulse Pressure Variation (PPV) Compared with Stroke Volume Variation (SVV) in Predicting Fluid Responsiveness.

Authors:  Abhishek Rathore; Shalendra Singh; Ritesh Lamsal; Priya Taank; Debashish Paul
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-08-01

6.  Vigilance of hemodynamic changes immediately after transferring patients is crucial.

Authors:  Zen'ichiro Wajima; Toshiya Shiga; Kazuyuki Imanaga; Tetsuo Inoue
Journal:  J Anesth       Date:  2013-03-01       Impact factor: 2.078

Review 7.  Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness.

Authors:  T G Eskesen; M Wetterslev; A Perner
Journal:  Intensive Care Med       Date:  2015-12-09       Impact factor: 17.440

8.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

9.  Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Juan Carlos Díaz Monrové
Journal:  Crit Care       Date:  2009-09-03       Impact factor: 9.097

10.  Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers.

Authors:  Pierre Squara; Dominique Rotcajg; Dominique Denjean; Philippe Estagnasie; Alain Brusset
Journal:  Crit Care       Date:  2009-07-28       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.