Literature DB >> 25027840

Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

Antonios E Papadakis1, Kostas Perisinakis, John Damilakis.   

Abstract

OBJECTIVES: To study the effect of patient size, body region and modulation strength on tube current and image quality on CT examinations that use automatic tube current modulation (ATCM).
METHODS: Ten physical anthropomorphic phantoms that simulate an individual as neonate, 1-, 5-, 10-year-old and adult at various body habitus were employed. CT acquisition of head, neck, thorax and abdomen/pelvis was performed with ATCM activated at weak, average and strong modulation strength. The mean modulated mAs (mAsmod) values were recorded. Image noise was measured at selected anatomical sites.
RESULTS: The mAsmod recorded for neonate compared to 10-year-old increased by 30 %, 14 %, 6 % and 53 % for head, neck, thorax and abdomen/pelvis, respectively, (P < 0.05). The mAsmod was lower than the preselected mAs with the exception of the 10-year-old phantom. In paediatric and adult phantoms, the mAsmod ranged from 44 and 53 for weak to 117 and 93 for strong modulation strength, respectively. At the same exposure parameters image noise increased with body size (P < 0.05).
CONCLUSIONS: The ATCM system studied here may affect dose differently for different patient habitus. Dose may decrease for overweight adults but increase for children older than 5 years old. Care should be taken when implementing ATCM protocols to ensure that image quality is maintained. KEY POINTS: • ATCM efficiency is related to the size of the patient's body. • ATCM should be activated without caution in overweight adult individuals. • ATCM may increase radiation dose in children older than 5 years old. • ATCM efficiency depends on the protocol selected for a specific anatomical region. • Modulation strength may be appropriately tuned to enhance ATCM efficiency.

Entities:  

Mesh:

Year:  2014        PMID: 25027840     DOI: 10.1007/s00330-014-3309-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Ravi S Kamath; Elkan F Halpern; Sanjay Saini
Journal:  Radiology       Date:  2004-08       Impact factor: 11.105

2.  Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

Authors:  Marco Das; Andreas Horst Mahnken; Georg Mühlenbruch; Achim Stargardt; Claudia Weiss; Dirk-Alexander Sennst; Thomas G Flohr; Rolf W Günther; Joachim Ernst Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

3.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

4.  The effect of angular and longitudinal tube current modulations on the estimation of organ and effective doses in x-ray computed tomography.

Authors:  Marcel van Straten; Paul Deak; Paul C Shrimpton; Willi A Kalender
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

5.  Relating noise to image quality indicators in CT examinations with tube current modulation.

Authors:  Justin B Solomon; Xiang Li; Ehsan Samei
Journal:  AJR Am J Roentgenol       Date:  2013-03       Impact factor: 3.959

6.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

Review 7.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

8.  Angular on-line tube current modulation in multidetector CT examinations of children and adults: the influence of different scanning parameters on dose reduction.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

9.  Dose reduction in multidetector CT using attenuation-based online tube current modulation.

Authors:  Denis Tack; Viviane De Maertelaer; Pierre Alain Gevenois
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

10.  Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.

Authors:  Hervé J Brisse; Magalie Robilliard; Alexia Savignoni; Noelle Pierrat; Geneviève Gaboriaud; Yann De Rycke; Sylvia Neuenschwander; Bernard Aubert; Jean-Claude Rosenwald
Journal:  Health Phys       Date:  2009-10       Impact factor: 1.316

View more
  10 in total

1.  Optimizing radiation exposure in screening of body packing: image quality and diagnostic acceptability of an 80 kVp protocol with automated tube current modulation.

Authors:  Joel Aissa; Johannes Boos; Christian Rubbert; Julian Caspers; Christoph Schleich; Christoph Thomas; Patric Kröpil; Gerald Antoch; Falk Miese
Journal:  Forensic Sci Med Pathol       Date:  2017-03-07       Impact factor: 2.007

2.  Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality.

Authors:  G Solomou; A E Papadakis; J Damilakis
Journal:  Eur Radiol       Date:  2014-11-28       Impact factor: 5.315

3.  Helical CT with variable target noise levels for dose reduction in chest, abdomen and pelvis CT.

Authors:  Patrik Rogalla; Madhusudan Paravasthu; Christin Farrell; Sonja Kandel
Journal:  Eur Radiol       Date:  2018-03-21       Impact factor: 5.315

4.  Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Acad Radiol       Date:  2018-08-30       Impact factor: 3.173

5.  A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation: Phantom and patient study.

Authors:  Wanlin Peng; Zhenlin Li; Chunchao Xia; Yingkun Guo; Jinge Zhang; Kai Zhang; Lei Li; Fei Zhao
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

6.  Joint European Society of Paediatric Radiology (ESPR) and International Society for Forensic Radiology and Imaging (ISFRI) guidelines: paediatric postmortem computed tomography imaging protocol.

Authors:  Susan C Shelmerdine; Chandra Y Gerrard; Padma Rao; Matthew Lynch; Jeroen Kroll; Dan Martin; Elka Miller; Laura Filograna; Rosa Maria Martinez; Odey Ukpo; Barry Daly; Hideki Hyodoh; Karl Johnson; Andrew Watt; Ajay Taranath; Scott Brown; David Perry; Lene Warner Thorup Boel; Aleksandra Borowska-Solonynko; Rick van Rijn; Willemijn Klein; Elspeth Whitby; Owen J Arthurs
Journal:  Pediatr Radiol       Date:  2019-02-28

7.  Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality.

Authors:  Antonios E Papadakis; John Damilakis
Journal:  Invest Radiol       Date:  2019-05       Impact factor: 6.016

8.  Evaluation of an organ-based tube current modulation tool in pediatric CT examinations.

Authors:  Antonios E Papadakis; John Damilakis
Journal:  Eur Radiol       Date:  2020-05-20       Impact factor: 5.315

9.  A new brain CT reference line: the lower eyelid to the inner occipital base line closely parallels the Talairach-Tournoux line.

Authors:  Hiroshi Ishizaka; Minoru Naka; Hiroyuki Nagase; Katsumi Yanagisawa; Toshio Kubota; Hideo Morita; Yoshito Tsushima
Journal:  Acta Radiol Open       Date:  2020-01-27

10.  Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms.

Authors:  Sarah-May Gould; Jane Mackewn; Sugama Chicklore; Gary J R Cook; Andrew Mallia; Lucy Pike
Journal:  EJNMMI Phys       Date:  2021-07-31
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.