Literature DB >> 17821994

Angular on-line tube current modulation in multidetector CT examinations of children and adults: the influence of different scanning parameters on dose reduction.

Antonios E Papadakis1, Kostas Perisinakis, John Damilakis.   

Abstract

The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM in neonates and young children was found to be lower than that obtained for adults. Therefore, on-line TCM should work as an additional means to reduce dose and should not replace other conventional means of reducing dose, especially in neonates and young children.

Entities:  

Mesh:

Year:  2007        PMID: 17821994     DOI: 10.1118/1.2747048

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

Review 1.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

2.  Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Eur Radiol       Date:  2014-07-17       Impact factor: 5.315

3.  Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality.

Authors:  G Solomou; A E Papadakis; J Damilakis
Journal:  Eur Radiol       Date:  2014-11-28       Impact factor: 5.315

4.  Helical CT with variable target noise levels for dose reduction in chest, abdomen and pelvis CT.

Authors:  Patrik Rogalla; Madhusudan Paravasthu; Christin Farrell; Sonja Kandel
Journal:  Eur Radiol       Date:  2018-03-21       Impact factor: 5.315

5.  Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction.

Authors:  Maria Raissaki; Kostas Perisinakis; John Damilakis; Nicholas Gourtsoyiannis
Journal:  Pediatr Radiol       Date:  2010-06-16

6.  Image Quality and Radiation Dose of Contrast-Enhanced Chest-CT Acquired on a Clinical Photon-Counting Detector CT vs. Second-Generation Dual-Source CT in an Oncologic Cohort: Preliminary Results.

Authors:  Florian Hagen; Lukas Walder; Jan Fritz; Ralf Gutjahr; Bernhard Schmidt; Sebastian Faby; Fabian Bamberg; Stefan Schoenberg; Konstantin Nikolaou; Marius Horger
Journal:  Tomography       Date:  2022-06-03

7.  Effective dose estimation in whole-body multislice CT in paediatric trauma patients.

Authors:  Robin D Munk; Peter C Strohm; Ulrich Saueressig; Joern Zwingmann; Markus Uhl; Norbert P Südkamp; Elmar Kotter; Mathias Langer; Thorsten A Bley
Journal:  Pediatr Radiol       Date:  2009-01-16

8.  Feasibility Study of Dose Modulation for Reducing Radiation Dose with Arms-Down Patient Position in Abdominal Computed Tomography.

Authors:  Jina Shim; Yong Eun Chung; Hyun-Woo Jeong; Youngjin Lee
Journal:  Diagnostics (Basel)       Date:  2022-01-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.