Literature DB >> 15855093

Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

Marco Das1, Andreas Horst Mahnken, Georg Mühlenbruch, Achim Stargardt, Claudia Weiss, Dirk-Alexander Sennst, Thomas G Flohr, Rolf W Günther, Joachim Ernst Wildberger.   

Abstract

OBJECTIVE: The purpose of our study was to develop a simple protocol for reduction of radiation exposure without loss of diagnostic information in chest 16-MDCT.
MATERIALS AND METHODS: Two hundred and four patients underwent MDCT of the thorax (Somatom Sensation 16, Siemens). Group 1 was scanned using a standard protocol with 100 mAs(effective) (mAs(eff)). Group 2 was scanned using a dose modulation template (CareDose). Group 3 was scanned with mAs(eff) = body weight (kg). Group 4 was scanned with a combination of weight-adapted mAs(eff) and dose modulation. All other parameters were kept constant. Signal-to-noise ratio was assessed as an objective measurement for image quality, and subjective image quality was rated by three experienced radiologists on a 4-point scale. Effective dose was calculated using dedicated software.
RESULTS: The mean noise measurement values were 8.31 H for the 100 mAs(eff) protocol for the regression between weight and signal-to-noise (p < 0.0001), 9.08 H for group 2 (p < 0.0001), 9.0 H for group 3 (p = 0.5051), and 9.98 H for group 4 (p = 0.0152). The median image quality was 1 (1 = highest quality) in all subgroups. The mean effective dose was 6.83 mSv, 5.92 mSv, 4.73 mSv, and 3.97 mSv, respectively. The least correlation between weight and image noise was achieved for the individually weight-adapted protocol and in the weight-adapted with CareDose combination.
CONCLUSION: By tube current time product adaptation (kg = mAs(eff)) combined with an online tube current modulation template, a well-balanced examination without significant loss of information was achieved for this specific scanner. Thus, individually adapted protocols for chest 16-MDCT can be recommended.

Entities:  

Mesh:

Year:  2005        PMID: 15855093     DOI: 10.2214/ajr.184.5.01841437

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

2.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients.

Authors:  François Pontana; Alain Duhamel; Julien Pagniez; Thomas Flohr; Jean-Baptiste Faivre; Anne-Lise Hachulla; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2010-11-16       Impact factor: 5.315

3.  The influences of tube voltage and scan direction on combined tube current modulation: a phantom study.

Authors:  Hyun Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-04-27

Review 4.  Applications of cardiac multidetector CT beyond coronary angiography.

Authors:  Karl H Schuleri; Richard T George; Albert C Lardo
Journal:  Nat Rev Cardiol       Date:  2009-11       Impact factor: 32.419

5.  Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Eur Radiol       Date:  2014-07-17       Impact factor: 5.315

6.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

Review 7.  CT protocols in interstitial lung diseases--a survey among members of the European Society of Thoracic Imaging and a review of the literature.

Authors:  Helmut Prosch; Cornelia M Schaefer-Prokop; Edith Eisenhuber; Daniela Kienzl; Christian J Herold
Journal:  Eur Radiol       Date:  2012-12-13       Impact factor: 5.315

8.  Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

Authors:  Zilai Pan; Lifang Pang; Jianying Li; Huan Zhang; Wenjie Yang; Bei Ding; Weimin Chai; Kemin Chen; Weiwu Yao
Journal:  Int J Cardiovasc Imaging       Date:  2010-09-18       Impact factor: 2.357

9.  Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients.

Authors:  A G d'Agostino; M Remy-Jardin; C Khalil; V Delannoy-Deken; T Flohr; A Duhamel; J Remy
Journal:  Eur Radiol       Date:  2006-04-12       Impact factor: 5.315

10.  Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT.

Authors:  Weiwei Qi; Jianying Li; Xiangke Du
Journal:  Korean J Radiol       Date:  2009 Nov-Dec       Impact factor: 3.500

View more