Literature DB >> 29564595

Helical CT with variable target noise levels for dose reduction in chest, abdomen and pelvis CT.

Patrik Rogalla1, Madhusudan Paravasthu1, Christin Farrell1, Sonja Kandel2.   

Abstract

OBJECTIVES: To evaluate a contiguous helical CT protocol with two different target noise levels in chest/abdomen/pelvis CT.
METHODS: 41 patients (study group) underwent a helical scan (P1) with two different target noise levels (SDs), SD = 16 for chest and SD = 13 for abdomen/pelvis. Two further protocols were planned but not executed: a single helical scan with only one SD (SD = 13) for the entire scan range (P2), and two separate helical scans overlapping over the liver and same SD settings as for P1 (P3). All DLPs were recorded. Image quality was assessed qualitatively and quantitatively on all scans. The control group consisted of 40 patients, was scanned with protocol P3 and analysed using the same metrics.
RESULTS: DLPs (mean/SD) for P1, P2 and P3 were 859.5/392.9, 1040.2/510.5 and 1027.4/469.4, respectively. P1 offered a mean dose reduction of 17.4% compared to P2, and 16.3% compared to P3 (both p < 0.001). There were no differences in image quality between both patient groups (p > 0.3).
CONCLUSION: Contiguous helical scanning of the chest/abdomen/pelvis with variable target noise levels results in approximately 17% dose reduction if compared to a single acquisition with only abdominal dose settings or two separate acquisitions of the chest and abdomen/pelvis. KEY POINTS: • Low dose chest and standard abdomen CTs can be combined. • Variable SD CT scanning allows for radiation dose reduction. • Variable SD CT scanning maintains image quality.

Entities:  

Keywords:  CT technique; Dose modulation; Dose reduction; Image quality; Whole body CT

Mesh:

Year:  2018        PMID: 29564595     DOI: 10.1007/s00330-018-5315-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

Review 1.  Cancer risk from low-level radiation.

Authors:  Bernard L Cohen
Journal:  AJR Am J Roentgenol       Date:  2002-11       Impact factor: 3.959

2.  Dose-length product to effective dose conversion factors for common computed tomography examinations based on Canadian clinical experience.

Authors:  Idris A Elbakri; Iain D C Kirkpatrick
Journal:  Can Assoc Radiol J       Date:  2012-03-09       Impact factor: 2.248

3.  Automatic exposure control in CT: are we done yet?

Authors:  Cynthia H McCollough
Journal:  Radiology       Date:  2005-12       Impact factor: 11.105

4.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

5.  Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Eur Radiol       Date:  2014-07-17       Impact factor: 5.315

6.  Low-dose CT of the lungs: preliminary observations.

Authors:  D P Naidich; C H Marshall; C Gribbin; R S Arams; D I McCauley
Journal:  Radiology       Date:  1990-06       Impact factor: 11.105

Review 7.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

8.  Angular on-line tube current modulation in multidetector CT examinations of children and adults: the influence of different scanning parameters on dose reduction.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

9.  Attenuation-based automatic kilovoltage selection and sinogram-affirmed iterative reconstruction: effects on radiation exposure and image quality of portal-phase liver CT.

Authors:  Ji Soo Song; Eun Jung Choi; Eun Young Kim; Hyo Sung Kwak; Young Min Han
Journal:  Korean J Radiol       Date:  2015-01-09       Impact factor: 3.500

10.  Exposure to low dose computed tomography for lung cancer screening and risk of cancer: secondary analysis of trial data and risk-benefit analysis.

Authors:  Cristiano Rampinelli; Paolo De Marco; Daniela Origgi; Patrick Maisonneuve; Monica Casiraghi; Giulia Veronesi; Lorenzo Spaggiari; Massimo Bellomi
Journal:  BMJ       Date:  2017-02-08
View more
  1 in total

1.  Spiral Computed Tomography in the Quantitative Measurement of the Adjacent Structure of the Left Atrial Appendage in Patients with Atrial Fibrillation.

Authors:  Zhen Zhang; Wei Yan
Journal:  J Healthc Eng       Date:  2021-11-30       Impact factor: 2.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.