Literature DB >> 23436849

Relating noise to image quality indicators in CT examinations with tube current modulation.

Justin B Solomon1, Xiang Li, Ehsan Samei.   

Abstract

OBJECTIVE: Modern CT systems use surrogates of noise-noise index (NI) and quality reference effective tube current-time product (Q)-to infer the quality of images acquired using tube current modulation. This study aimed to determine the relationship between actual noise and these surrogates for two CT scanners from two different manufacturers.
MATERIALS AND METHODS: Two phantoms (adult and 1-year-old child) were imaged on two CT scanners (64 and 128 MDCT) using a clinical range of NI (6-22) and Q (30-300 mA). Each scan was performed twice, and noise was measured in the mediastinum, lung, and abdomen using an image subtraction technique. The effect on noise from changing other imaging parameters, such as beam collimation, pitch, peak kilovoltage, slice thickness, FOV, reconstruction kernel or algorithm, and patient age category (adult or pediatric), was investigated.
RESULTS: On the 64-MDCT scanner, noise increased linearly along with NI, with the slope affected by changing the anatomy of interest, peak kilovoltage, reconstruction algorithm, and convolution kernel. The noise-NI relationship was independent of phantom size, slice thickness, pitch, FOV, and beam width. On the 128-MDCT scanner, noise decreased nonlinearly along with increasing Q, slice thickness, and peak tube voltage. The noise-Q relationship also depended on anatomy of interest, phantom size, age selection, and reconstruction algorithm but was independent of pitch, FOV, and detector configuration.
CONCLUSION: We established how noise changes with changing image quality indicators across a clinically relevant range of imaging parameters. This work can aid in optimizing protocols by targeting specific noise levels for different types of CT examinations.

Entities:  

Mesh:

Year:  2013        PMID: 23436849     DOI: 10.2214/AJR.12.8580

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  15 in total

1.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

2.  Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Eur Radiol       Date:  2014-07-17       Impact factor: 5.315

3.  Investigating the CT localizer radiograph: acquisition parameters, patient centring and their combined influence on radiation dose.

Authors:  J W Lambert; S Kumar; J S Chen; Z J Wang; R G Gould; B M Yeh
Journal:  Br J Radiol       Date:  2015-01-22       Impact factor: 3.039

4.  Emerging techniques for dose optimization in abdominal CT.

Authors:  Ravi K Kaza; Joel F Platt; Mitchell M Goodsitt; Mahmoud M Al-Hawary; Katherine E Maturen; Ashish P Wasnik; Amit Pandya
Journal:  Radiographics       Date:  2014 Jan-Feb       Impact factor: 5.333

5.  Size-based quality-informed framework for quantitative optimization of pediatric CT.

Authors:  Ehsan Samei; Xiang Li; Donald P Frush
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-21

6.  Accounting for reconstruction kernel-induced variability in CT radiomic features using noise power spectra.

Authors:  Muhammad Shafiq-Ul-Hassan; Geoffrey G Zhang; Dylan C Hunt; Kujtim Latifi; Ghanim Ullah; Robert J Gillies; Eduardo G Moros
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-14

7.  A scanner-specific framework for simulating CT images with tube current modulation.

Authors:  Giavanna Jadick; Ehsan Abadi; Brian Harrawood; Shobhit Sharma; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2021-09-13       Impact factor: 3.609

8.  Effect of CTA Tube Current on Spot Sign Detection and Accuracy for Prediction of Intracerebral Hemorrhage Expansion.

Authors:  A Morotti; J M Romero; M J Jessel; H B Brouwers; R Gupta; K Schwab; A Vashkevich; A Ayres; C D Anderson; M E Gurol; A Viswanathan; S M Greenberg; J Rosand; J N Goldstein
Journal:  AJNR Am J Neuroradiol       Date:  2016-05-19       Impact factor: 3.825

9.  Computed Tomography Angiography of Carotid Arteries and Vertebrobasilar System: A Simulation Study for Radiation Dose Reduction.

Authors:  Manuel Kramer; Stephan Ellmann; Thomas Allmendinger; Achim Eller; Ferdinand Kammerer; Matthias S May; João F Baigger; Michael Uder; Michael M Lell
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

10.  Effect of tube current on computed tomography radiomic features.

Authors:  Dennis Mackin; Rachel Ger; Cristina Dodge; Xenia Fave; Pai-Chun Chi; Lifei Zhang; Jinzhong Yang; Steve Bache; Charles Dodge; A Kyle Jones; Laurence Court
Journal:  Sci Rep       Date:  2018-02-05       Impact factor: 4.379

View more