Literature DB >> 24962826

Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose.

Benjamin Dubourg1, Jérôme Caudron, Jean-Pierre Lestrat, Michael Bubenheim, Valentin Lefebvre, Matthieu Godin, Christophe Tron, Hélène Eltchaninoff, Fabrice Bauer, Jean-Nicolas Dacher.   

Abstract

OBJECTIVES: To compare image quality and radiation dose of pre-transcatheter aortic valve implantation (TAVI) aortoiliofemoral CT angiography (AICTA) provided by standard vs. dual-energy mode with reduced iodine load protocols.
METHODS: One hundred and sixty-one patients underwent a two-step CTA protocol before TAVI including cardiac CTA with injection of 65 mL of iodinated contrast agent (ICA), immediately followed by AICTA. From this second acquisition, the following three different patient groups were identified: Group 1: 52 patients with standard AICTA (60 mL ICA, 100 kVp, mA automodulation); Group 2: 48 patients with dual-energy AICTA with 50 % iodine load reduction (30 mL ICA, fast kVp switching, 600 mA); Group 3: 61 patients with an identical protocol to Group 2, but exposed to 375 mA. The qualitative/subjective image quality (13-point score) and quantitative/objective image quality (contrast attenuation and image noise) were evaluated. The radiation dose was recorded.
RESULTS: There was no significant difference in non-diagnostic images between the three protocols. Contrast attenuation, signal-to-noise ratio and contrast-to-noise ratio were significantly higher, whereas noise was significantly lower in the standard protocol (all P < 0.05). The radiation dose was lower in the dual-energy protocol at 375 mA (P < 0.05).
CONCLUSIONS: Dual-energy AICTA before TAVI results in a reduction of iodine load while maintaining sufficient diagnostic information despite increased noise. KEY POINTS: • Dual-energy AICTA before TAVI results in a 50 % reduction of iodine load. •The reduction of iodine load maintains sufficient image quality despite increased noise. • Using 375 mA in dual-energy mode results in a reduction of radiation dose. • A high tube current setting (600 mA) should be used in overweight patients.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24962826     DOI: 10.1007/s00330-014-3263-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?

Authors:  Courtney A Coursey; Rendon C Nelson; Daniel T Boll; Erik K Paulson; Lisa M Ho; Amy M Neville; Daniele Marin; Rajan T Gupta; Sebastian T Schindera
Journal:  Radiographics       Date:  2010 Jul-Aug       Impact factor: 5.333

2.  Ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography.

Authors:  Subodh B Joshi; Dorinna D Mendoza; Daniel H Steinberg; Matthew A Goldstein; Cristian F Lopez; Arnold Raizon; Gaby Weissman; Lowell F Satler; Augusto D Pichard; Wm Guy Weigold
Journal:  JACC Cardiovasc Imaging       Date:  2009-12

3.  Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings.

Authors:  Takeshi Nakaura; Kazuo Awai; Seitaro Oda; Yoshinori Funama; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

4.  Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.

Authors:  Sanjeeva P Kalva; Dushyant V Sahani; Peter F Hahn; Sanjay Saini
Journal:  J Comput Assist Tomogr       Date:  2006 May-Jun       Impact factor: 1.826

Review 5.  European Society of Urogenital Radiology guidelines on contrast media application.

Authors:  Henrik S Thomsen
Journal:  Curr Opin Urol       Date:  2007-01       Impact factor: 2.309

6.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

7.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT.

Authors:  Kazuhiro Matsumoto; Masahiro Jinzaki; Yutaka Tanami; Akihisa Ueno; Minoru Yamada; Sachio Kuribayashi
Journal:  Radiology       Date:  2011-02-17       Impact factor: 11.105

8.  Role of multislice computed tomography in transcatheter aortic valve replacement.

Authors:  David A Wood; Laurens F Tops; John R Mayo; Sanjeevan Pasupati; Martin J Schalij; Karin Humphries; May Lee; Abdullah Al Ali; Brad Munt; Rob Moss; Christopher R Thompson; Jeroen J Bax; John G Webb
Journal:  Am J Cardiol       Date:  2009-05-01       Impact factor: 2.778

9.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience.

Authors:  Alain Cribier; Helene Eltchaninoff; Christophe Tron; Fabrice Bauer; Carla Agatiello; Deborah Nercolini; Sydney Tapiero; Pierre-Yves Litzler; Jean-Paul Bessou; Vasilis Babaliaros
Journal:  J Am Coll Cardiol       Date:  2006-02-09       Impact factor: 24.094

10.  Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation.

Authors:  Fabian Plank; Guy Friedrich; Thomas Bartel; Silvana Mueller; Nikolaos Bonaros; Anneliese Heinz; Andrea Klauser; Fabiola Cartes-Zumelzu; Michael Grimm; Gudrun Feuchtner
Journal:  Ann Thorac Surg       Date:  2012-08-24       Impact factor: 4.330

View more
  13 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

2.  CT angiography of the kidney using routine CT and the latest Gemstone Spectral Imaging combination of different noise indexes: image quality and radiation dose.

Authors:  Yongxia Zhao; Yanmin Wu; Ziwei Zuo; Shujie Cheng
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

3.  Spectral detector CT for cardiovascular applications.

Authors:  Prabhakar Rajiah; Suhny Abbara; Sandra Simon Halliburton
Journal:  Diagn Interv Radiol       Date:  2017 May-Jun       Impact factor: 2.630

4.  Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.

Authors:  Simon S Martin; Moritz H Albrecht; Julian L Wichmann; Kristina Hüsers; Jan-Erik Scholtz; Christian Booz; Boris Bodelle; Ralf W Bauer; Sarah C Metzger; Thomas J Vogl; Thomas Lehnert
Journal:  Eur Radiol       Date:  2016-05-28       Impact factor: 5.315

5.  Dual-energy computed tomography for evaluation of breast cancer: value of virtual monoenergetic images reconstructed with a noise-reduced monoenergetic reconstruction algorithm.

Authors:  Kanako Okada; Megumi Matsuda; Takaharu Tsuda; Teruhito Kido; Akihiro Murata; Hikaru Nishiyama; Kanako Nishiyama; Haruna Yamasawa; Yoshiaki Kamei; Mie Kurata; Mana Fukushima; Riko Kitazawa; Teruhito Mochizuki
Journal:  Jpn J Radiol       Date:  2019-11-04       Impact factor: 2.374

6.  CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease.

Authors:  Shunsuke Matsumoto; Yoshitake Yamada; Masahiro Hashimoto; Teppei Okamura; Minoru Yamada; Fumiaki Yashima; Kentaro Hayashida; Keiichi Fukuda; Masahiro Jinzaki
Journal:  Eur Radiol       Date:  2016-08-25       Impact factor: 5.315

7.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

Review 8.  Vascular Imaging Before Transcatheter Aortic Valve Replacement (TAVR): Why and How?

Authors:  Damiano Caruso; Russell D Rosenberg; Carlo N De Cecco; Stefanie Mangold; Julian L Wichmann; Akos Varga-Szemes; Daniel H Steinberg; Andrea Laghi; U Joseph Schoepf
Journal:  Curr Cardiol Rep       Date:  2016-02       Impact factor: 2.931

9.  Possible Contrast Media Reduction with Low keV Monoenergetic Images in the Detection of Focal Liver Lesions: A Dual-Energy CT Animal Study.

Authors:  Yong Eun Chung; Je Sung You; Hye-Jeong Lee; Joon Seok Lim; Hye Sun Lee; Song-Ee Baek; Myeong-Jin Kim
Journal:  PLoS One       Date:  2015-07-23       Impact factor: 3.240

Review 10.  Dual-energy CT of acute bowel ischemia.

Authors:  Markus M Obmann; Gopal Punjabi; Verena C Obmann; Daniel T Boll; Tobias Heye; Matthias R Benz; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2021-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.