Literature DB >> 21386048

Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Sarabjeet Singh1, Mannudeep K Kalra, Matthew D Gilman, Jiang Hsieh, Homer H Pien, Subba R Digumarthy, Jo-Anne O Shepard.   

Abstract

PURPOSE: To compare lesion detection and image quality of chest computed tomographic (CT) images acquired at various tube current-time products (40-150 mAs) and reconstructed with adaptive statistical iterative reconstruction (ASIR) or filtered back projection (FBP).
MATERIALS AND METHODS: In this Institutional Review Board-approved HIPAA-compliant study, CT data from 23 patients (mean age, 63 years ± 7.3 [standard deviation]; 10 men, 13 women) were acquired at varying tube current-time products (40, 75, 110, and 150 mAs) on a 64-row multidetector CT scanner with 10-cm scan length. All patients gave informed consent. Data sets were reconstructed at 30%, 50%, and 70% ASIR-FBP blending. Two thoracic radiologists assessed image noise, visibility of small structures, lesion conspicuity, and diagnostic confidence. Objective noise and CT number were measured in the thoracic aorta. CT dose index volume, dose-length product, weight, and transverse diameter were recorded. Data were analyzed by using analysis of variance and the Wilcoxon signed rank test.
RESULTS: FBP had unacceptable noise at 40 and 75 mAs in 17 and five patients, respectively, whereas ASIR had acceptable noise at 40-150 mAs. Objective noise with 30%, 50%, and 70% ASIR blending (11.8 ± 3.8, 9.6 ± 3.1, and 7.5 ± 2.6, respectively) was lower than that with FBP (15.8 ± 4.8) (P < .0001). No lesions were missed on FBP or ASIR images. Lesion conspicuity was graded as well seen on both FBP and ASIR images (P < .05). Mild pixilated blotchy texture was noticed with 70% blended ASIR images.
CONCLUSION: Acceptable image quality can be obtained for chest CT images acquired at 40 mAs by using ASIR without any substantial artifacts affecting diagnostic confidence. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101450/-/DC1. RSNA, 2011

Entities:  

Mesh:

Year:  2011        PMID: 21386048     DOI: 10.1148/radiol.11101450

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  113 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography.

Authors:  Jiro Sato; Masaaki Akahane; Sachiko Inano; Mariko Terasaki; Hiroyuki Akai; Masaki Katsura; Izuru Matsuda; Akira Kunimatsu; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-17       Impact factor: 2.374

4.  Current status of low dose multi-detector CT in the urinary tract.

Authors:  Mi Kim Sung; Sarabjeet Singh; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2011-11-28

5.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

6.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

7.  The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

Authors:  Heejin Kwon; Jinhan Cho; Jongyeong Oh; Dongwon Kim; Junghyun Cho; Sanghyun Kim; Sangyun Lee; Jihyun Lee
Journal:  Br J Radiol       Date:  2015-08-03       Impact factor: 3.039

8.  Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.

Authors:  Katharina Martini; Kai Higashigaito; Borna K Barth; Stephan Baumueller; Hatem Alkadhi; Thomas Frauenfelder
Journal:  Br J Radiol       Date:  2015-10-22       Impact factor: 3.039

9.  Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

Authors:  F Gay; Y Pavia; N Pierrat; S Lasalle; S Neuenschwander; H J Brisse
Journal:  Eur Radiol       Date:  2013-08-31       Impact factor: 5.315

10.  Quantifying the effect of slice thickness, intravenous contrast and tube current on muscle segmentation: Implications for body composition analysis.

Authors:  Georg Fuchs; Yves R Chretien; Julia Mario; Synho Do; Matthias Eikermann; Bob Liu; Kai Yang; Florian J Fintelmann
Journal:  Eur Radiol       Date:  2018-01-09       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.