Literature DB >> 26768740

Vascular Imaging Before Transcatheter Aortic Valve Replacement (TAVR): Why and How?

Damiano Caruso1,2, Russell D Rosenberg3, Carlo N De Cecco4,5, Stefanie Mangold6,7, Julian L Wichmann8,9, Akos Varga-Szemes10, Daniel H Steinberg11, Andrea Laghi12, U Joseph Schoepf13,14,15.   

Abstract

Transcatheter aortic valve replacement (TAVR) has become an alternative to surgical intervention for symptomatic or severe aortic valve stenosis in patients with high surgical risk. Successful TAVR requires a multimodality imaging approach for appropriate patient selection and prosthesis sizing. Here, we describe individual imaging modalities and report their respective roles in this emerging field. To date, echocardiography remains the traditional test for determining patient candidacy and prosthesis selection, but computed tomography (CT) has been taking on an increasingly important role in the evaluation of both the aortic root anatomy and aortoiliofemoral vessels as a single examination. Cardiac magnetic resonance (CMR) is useful in grading the severity of aortic stenosis and should be considered a reasonable alternative to CT for the evaluation of the aortic annulus, e.g., when the administration of contrast media is contraindicated.

Entities:  

Keywords:  Aortic stenosis; Cardiac magnetic resonance; Computed tomography; Echocardiography; Transcatheter aortic valve implantation; Transcatheter aortic valve replacement

Mesh:

Substances:

Year:  2016        PMID: 26768740     DOI: 10.1007/s11886-015-0694-5

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  98 in total

1.  Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation.

Authors:  Ronen Gurvitch; John G Webb; Ren Yuan; Mark Johnson; Cameron Hague; Alexander B Willson; Stefan Toggweiler; David A Wood; Jian Ye; Robert Moss; Christopher R Thompson; Stephan Achenbach; James K Min; Troy M Labounty; Ricardo Cury; Jonathon Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2011-11       Impact factor: 11.195

2.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

Review 3.  Patient selection--risk assessment and anatomical selection criteria for patients undergoing transfemoral aortic valve implantation.

Authors:  Itsik Ben-Dor; Ron Waksman; Lowell F Satler; Augusto D Pichard
Journal:  Cardiovasc Revasc Med       Date:  2010 Apr-Jun

4.  CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation.

Authors:  Borek Foldyna; Camelia Jungert; Christian Luecke; Konstantin von Aspern; Sonja Boehmer-Lasthaus; Eva Maria Rueth; Matthias Grothoff; Stefan Nitzsche; Matthias Gutberlet; Friedrich Wilhelm Mohr; Lukas Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2015-04-19       Impact factor: 2.357

5.  Comparison of aortic annulus size by transesophageal echocardiography and computed tomography angiography with direct surgical measurement.

Authors:  Hanghang Wang; Jennifer M Hanna; Asvin Ganapathi; Jeffrey E Keenan; Lynne M Hurwitz; John P Vavalle; Todd L Kiefer; Andrew Wang; J Kevin Harrison; G Chad Hughes
Journal:  Am J Cardiol       Date:  2015-03-12       Impact factor: 2.778

Review 6.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

7.  Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI).

Authors:  C Schmidkonz; M Marwan; L Klinghammer; M Mitschke; A Schuhbaeck; M Arnold; M Lell; S Achenbach; T Pflederer
Journal:  Eur J Radiol       Date:  2014-06-19       Impact factor: 3.528

8.  Lipoprotein(a), Chlamydia pneumoniae, leptin and tissue plasminogen activator as risk markers for valvular aortic stenosis.

Authors:  C A Glader; L S Birgander; S Söderberg; H P Ildgruben; P Saikku; A Waldenström; G H Dahlén
Journal:  Eur Heart J       Date:  2003-01       Impact factor: 29.983

9.  Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.

Authors:  K von Aspern; B Foldyna; C D Etz; A Hoyer; F Girrbach; D Holzhey; C Lücke; M Grothoff; A Linke; F W Mohr; M Gutberlet; L Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-28       Impact factor: 2.357

10.  MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?

Authors:  Tomas Jurencak; Jakub Turek; Bastiaan L J H Kietselaer; Casper Mihl; Madeleine Kok; Vincent G V A van Ommen; Leen A F M van Garsse; Estelle C Nijssen; Joachim E Wildberger; Marco Das
Journal:  Eur Radiol       Date:  2015-02-24       Impact factor: 5.315

View more
  2 in total

Review 1.  Role of Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Corinna Storz; Tobias Geisler; Mike Notohamiprodjo; Konstantin Nikolaou; Fabian Bamberg
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-10

2.  The Iliofemoral tortuosity score predicts access and bleeding complications during transfemoral transcatheter aortic valve replacement: DataData from the VIenna Cardio Thoracic aOrtic valve registrY (VICTORY).

Authors:  Markus Mach; Thomas Poschner; Waseem Hasan; Philipp Szalkiewicz; Martin Andreas; Bernhard Winkler; Stephanie Geisler; Daniela Geisler; Piotr N Rudziński; Victoria Watzal; Andreas Strouhal; Christopher Adlbrecht; Georg Delle-Karth; Martin Grabenwöger
Journal:  Eur J Clin Invest       Date:  2021-02-02       Impact factor: 4.686

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.