Literature DB >> 27562479

CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease.

Shunsuke Matsumoto1, Yoshitake Yamada2, Masahiro Hashimoto1, Teppei Okamura1, Minoru Yamada3, Fumiaki Yashima4, Kentaro Hayashida4, Keiichi Fukuda4, Masahiro Jinzaki5.   

Abstract

OBJECTIVES: To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD).
METHODS: Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time × weight [kg] × 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard.
RESULTS: The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV).
CONCLUSIONS: CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. KEY POINTS: • TAVI-planning CT using variable helical pitch (VHP) scanning is useful. • The average volume of contrast material was 38.7 ± 8.5 mL. • The average attenuations of all the arteries were >400 HU. • This CT had a high sensitivity and NPV for excluding obstructive CAD.

Entities:  

Keywords:  Contrast media; Coronary artery disease; Multidetector computed tomography; Sensitivity and specificity; Transcatheter aortic valve replacement

Mesh:

Substances:

Year:  2016        PMID: 27562479     DOI: 10.1007/s00330-016-4547-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

1.  Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.

Authors:  Brett S Harris; Carlo N De Cecco; U Joseph Schoepf; Daniel H Steinberg; Richard R Bayer; Aleksander W Krazinski; Kevin T Dyer; Monique K Sandhu; Michael R Zile; Felix G Meinel
Journal:  Radiology       Date:  2014-11-12       Impact factor: 11.105

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

3.  Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study.

Authors:  Jörg Hausleiter; Tanja S Meyer; Eugenio Martuscelli; Pietro Spagnolo; Hiroaki Yamamoto; Patricia Carrascosa; Thomas Anger; Lukas Lehmkuhl; Hatem Alkadhi; Stefan Martinoff; Martin Hadamitzky; Franziska Hein; Bernhard Bischoff; Miriam Kuse; Albert Schömig; Stephan Achenbach
Journal:  JACC Cardiovasc Imaging       Date:  2012-05

4.  Quantification of coronary artery calcium using ultrafast computed tomography.

Authors:  A S Agatston; W R Janowitz; F J Hildner; N R Zusmer; M Viamonte; R Detrano
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

5.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

6.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

7.  Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques.

Authors:  Yoshitake Yamada; Masahiro Jinzaki; Takahiro Hosokawa; Yutaka Tanami; Hiroaki Sugiura; Takayuki Abe; Sachio Kuribayashi
Journal:  Eur J Radiol       Date:  2012-08-09       Impact factor: 3.528

8.  Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure.

Authors:  Stefan Toggweiler; Ronen Gurvitch; Jonathon Leipsic; David A Wood; Alexander B Willson; Ronald K Binder; Anson Cheung; Jian Ye; John G Webb
Journal:  J Am Coll Cardiol       Date:  2012-01-10       Impact factor: 24.094

9.  Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience.

Authors:  Josep Rodés-Cabau; John G Webb; Anson Cheung; Jian Ye; Eric Dumont; Christopher M Feindel; Mark Osten; Madhu K Natarajan; James L Velianou; Giuseppe Martucci; Benoît DeVarennes; Robert Chisholm; Mark D Peterson; Samuel V Lichtenstein; Fabian Nietlispach; Daniel Doyle; Robert DeLarochellière; Kevin Teoh; Victor Chu; Adrian Dancea; Kevin Lachapelle; Asim Cheema; David Latter; Eric Horlick
Journal:  J Am Coll Cardiol       Date:  2010-01-22       Impact factor: 24.094

10.  How to reduce costs in transcatheter aortic valve implantation.

Authors:  Stefan Toggweiler
Journal:  Open Heart       Date:  2014-11-21
View more
  13 in total

1.  Protocol using wide-detector CT with single contrast injection for the aorta and coronary artery: variable helical pitch versus volume scan following helical scan.

Authors:  Nari Shin; Sung Mok Kim; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-06       Impact factor: 2.357

Review 2.  Percutaneous Coronary Intervention Pre-TAVR: Current State of the Evidence.

Authors:  Lukas S Keller; Vassili Panagides; Jules Mesnier; Jorge Nuche; Josep Rodés-Cabau
Journal:  Curr Cardiol Rep       Date:  2022-05-27       Impact factor: 3.955

3.  Clinical applications of cardiac computed tomography: a consensus paper of the European Association of Cardiovascular Imaging-part II.

Authors:  Gianluca Pontone; Alexia Rossi; Marco Guglielmo; Marc R Dweck; Oliver Gaemperli; Koen Nieman; Francesca Pugliese; Pal Maurovich-Horvat; Alessia Gimelli; Bernard Cosyns; Stephan Achenbach
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2022-03-22       Impact factor: 9.130

Review 4.  Challenges in Diagnosis and Functional Assessment of Coronary Artery Disease in Patients With Severe Aortic Stenosis.

Authors:  Srdjan Aleksandric; Marko Banovic; Branko Beleslin
Journal:  Front Cardiovasc Med       Date:  2022-03-11

Review 5.  Diagnostic accuracy of coronary computed tomography angiography for the evaluation of obstructive coronary artery disease in patients referred for transcatheter aortic valve implantation: a systematic review and meta-analysis.

Authors:  Marco Gatti; Guglielmo Gallone; Vittoria Poggi; Francesco Bruno; Alessandro Serafini; Alessandro Depaoli; Ovidio De Filippo; Federico Conrotto; Fatemeh Darvizeh; Riccardo Faletti; Gaetano Maria De Ferrari; Paolo Fonio; Fabrizio D'Ascenzo
Journal:  Eur Radiol       Date:  2022-02-22       Impact factor: 7.034

Review 6.  User-Friendly Vendor-Specific Guideline for Pediatric Cardiothoracic Computed Tomography Provided by the Asian Society of Cardiovascular Imaging Congenital Heart Disease Study Group: Part 1. Imaging Techniques.

Authors:  Sun Hwa Hong; Hyun Woo Goo; Eriko Maeda; Ki Seok Choo; I Chen Tsai
Journal:  Korean J Radiol       Date:  2019-02       Impact factor: 3.500

7.  CT Image Feature Diagnosis on the Basis of Deep Learning Algorithm for Preoperative Patients and Complications of Transcatheter Aortic Valve Implantation.

Authors:  Xiong Zheng; Zhang Qian; Xiaofang Wang; Zhen Zhang; Lei Liu
Journal:  J Healthc Eng       Date:  2021-11-29       Impact factor: 2.682

8.  Diagnostic accuracy of computed tomography angiography for the exclusion of coronary artery disease in candidates for transcatheter aortic valve implantation.

Authors:  Christopher Strong; António Ferreira; Rui Campante Teles; Gustavo Mendes; João Abecasis; Gonçalo Cardoso; Sara Guerreiro; Pedro Freitas; Ana Coutinho Santos; Carla Saraiva; João Brito; Luís Raposo; Pedro de Araújo Gonçalves; Henrique Mesquita Gabriel; Manuel de Sousa Almeida; Miguel Mendes
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

Review 9.  Coronary Artery Disease in Patients with Aortic Stenosis and Transcatheter Aortic Valve Implantation: Implications for Management.

Authors:  Antonio Fb de Azevedo Filho; Tarso Ad Accorsi; Henrique B Ribeiro
Journal:  Eur Cardiol       Date:  2021-12-07

10.  DEtection of ProxImal Coronary stenosis in the work-up for Transcatheter aortic valve implantation using CTA (from the DEPICT CTA collaboration).

Authors:  Thomas P W van den Boogert; Bimmer E P M Claessen; Maksymilian P Opolski; Won-Keun Kim; Ashraf Hamdan; Daniele Andreini; Francesca Pugliese; Helge Möllmann; Ronak Delewi; Jan Baan; M Marije Vis; Adrienne van Randen; Joost van Schuppen; Jaap Stoker; José P Henriques; R Nils Planken
Journal:  Eur Radiol       Date:  2021-06-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.