Dual-energy computed tomography for evaluation of breast cancer: value of virtual monoenergetic images reconstructed with a noise-reduced monoenergetic reconstruction algorithm.

Kanako Okada1, Megumi Matsuda2, Takaharu Tsuda2, Teruhito Kido2, Akihiro Murata2, Hikaru Nishiyama2, Kanako Nishiyama3, Haruna Yamasawa3, Yoshiaki Kamei3, Mie Kurata4, Mana Fukushima5, Riko Kitazawa5, Teruhito Mochizuki2,6.   

Abstract

PURPOSE: To evaluate the image quality and lesion visibility of virtual monoenergetic images (VMIs) reconstructed using a new monoenergetic reconstruction algorithm (nMERA) for evaluation of breast cancer.
MATERIALS AND METHODS: Forty-two patients with 46 breast cancers who underwent 4-phasic breast contrast-enhanced computed tomography (CT) using dual-energy CT (DECT) were enrolled. We selected the peak enhancement phase of the lesion in each patient. The selected phase images were generated by 120-kVp-equivalent linear blended (M120) and monoenergetic reconstructions from 40 to 80 keV using the standard reconstruction algorithm (sMERA: 40, 50, 60, 70, 80) and nMERA (40 +, 50 +, 60 +, 70 +, 80 +). The contrast-to-noise ratio (CNR) was calculated and objectively analyzed. Two independent readers subjectively scored tumor visibility and image quality each on a 5-point scale.
RESULTS: The CNR at 40 + and tumor visibility scores at 40 + and 50 + were significantly higher than those on M120. The CNR at 50 + was not significantly different from that on M120. However, the overall image quality score at 40 + was significantly lower than that at 50 + and on M120 (40 + vs M120, P < 0.0001 and 40 + vs 50 +, P = 0.0001).
CONCLUSIONS: VMI reconstructed with nMERA at 50 keV is preferable for evaluation of patients with breast cancer.

Entities:  

Keywords:  Breast cancer; Dual-energy computed tomography; Noise-reduced monoenergetic reconstruction algorithm; Virtual monoenergetic images

Mesh:

Year:  2019        PMID: 31686294     DOI: 10.1007/s11604-019-00897-1

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  49 in total

1.  Diagnosis of breast cancer with multidetector computed tomography: analysis of optimal delay time after contrast media injection.

Authors:  Seiko Kuroki-Suzuki; Yoshifumi Kuroki; Tsutomu Ishikawa; Hideya Takeo; Noriyuki Moriyama
Journal:  Clin Imaging       Date:  2010 Jan-Feb       Impact factor: 1.605

2.  Clinical implementation of contrast-enhanced four-dimensional dual-energy computed tomography for target delineation of pancreatic cancer.

Authors:  Shingo Ohira; Kentaro Wada; Takero Hirata; Naoyuki Kanayama; Toshiki Ikawa; Tsukasa Karino; Yuya Nitta; Masaru Isono; Yoshihiro Ueda; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  Radiother Oncol       Date:  2018-02-06       Impact factor: 6.280

3.  Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses.

Authors:  Sebastian Leschka; Paul Stolzmann; Stephan Baumüller; Hans Scheffel; Lotus Desbiolles; Bernhard Schmid; Borut Marincek; Hatem Alkadhi
Journal:  Acad Radiol       Date:  2010-04       Impact factor: 3.173

4.  Magnetic resonance imaging in patients with nipple discharge: should we recommend it?

Authors:  Michele Lorenzon; Chiara Zuiani; Anna Linda; Viviana Londero; Rossano Girometti; Massimo Bazzocchi
Journal:  Eur Radiol       Date:  2010-11-30       Impact factor: 5.315

5.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Authors:  Paul D Deak; Yulia Smal; Willi A Kalender
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

6.  Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant.

Authors:  Anno Graser; Christoph R Becker; Michael Staehler; Dirk A Clevert; Michael Macari; Niko Arndt; Konstantin Nikolaou; Wieland Sommer; Christian Stief; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-07       Impact factor: 6.016

7.  Diagnosis of breast tumors by contrast-enhanced MR imaging: comparison between the diagnostic performance of dynamic enhancement patterns and morphologic features.

Authors:  Mariko Goto; Hirotoshi Ito; Kentaro Akazawa; Takao Kubota; Osamu Kizu; Kei Yamada; Tsunehiko Nishimura
Journal:  J Magn Reson Imaging       Date:  2007-01       Impact factor: 4.813

8.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

9.  Objective and subjective image quality of liver parenchyma and hepatic metastases with virtual monoenergetic dual-source dual-energy CT reconstructions: an analysis in patients with gastrointestinal stromal tumor.

Authors:  Sonja Sudarski; Paul Apfaltrer; John W Nance; Mathias Meyer; Christian Fink; Peter Hohenberger; Christianne Leidecker; Stefan O Schoenberg; Thomas Henzler
Journal:  Acad Radiol       Date:  2014-04       Impact factor: 3.173

10.  Spinal dual-energy computed tomography: improved visualisation of spinal tumorous growth with a noise-optimised advanced monoenergetic post-processing algorithm.

Authors:  Mareen Kraus; Jakob Weiss; Nadja Selo; Thomas Flohr; Mike Notohamiprodjo; Fabian Bamberg; Konstantin Nikolaou; Ahmed E Othman
Journal:  Neuroradiology       Date:  2016-08-11       Impact factor: 2.804

View more
  6 in total

1.  Predicting axillary lymph node metastasis in breast cancer using the similarity of quantitative dual-energy CT parameters between the primary lesion and axillary lymph node.

Authors:  Kanako Terada; Hiroko Kawashima; Norihide Yoneda; Fumihito Toshima; Miki Hirata; Satoshi Kobayashi; Toshifumi Gabata
Journal:  Jpn J Radiol       Date:  2022-07-25       Impact factor: 2.701

2.  Dual-energy CT quantitative parameters for the differentiation of benign from malignant lesions and the prediction of histopathological and molecular subtypes in breast cancer.

Authors:  Xiaoxia Wang; Daihong Liu; Xiangfei Zeng; Shixi Jiang; Lan Li; Tao Yu; Jiuquan Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-05

3.  Giant epidermal inclusion cyst with infection arising within the breast parenchyma: a case report.

Authors:  Yongxia Zhang; Lei Song; Han Zhang; Fengjie Liu; Guo Hao; Jing Liu; Haizhu Xie; Hao Shi
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

4.  Dual-Energy Computed Tomography for Evaluation of Breast Cancer Follow-Ups: Comparison of Virtual Monoenergetic Images and Iodine-Map.

Authors:  Jun-Xian Li; Feng-Ji Xie; Chia-Hui Chen; Kuan-Ming Chen; Chia-Jung Tsai
Journal:  Diagnostics (Basel)       Date:  2022-04-10

5.  Subjective and Objective Assessment of Monoenergetic and Polyenergetic Images Acquired by Dual-Energy CT in Breast Cancer.

Authors:  Xiaoxia Wang; Daihong Liu; Shixi Jiang; Xiangfei Zeng; Lan Li; Tao Yu; Jiuquan Zhang
Journal:  Korean J Radiol       Date:  2021-01-19       Impact factor: 3.500

6.  Diagnostic value of dual-energy CT and clinicopathological and imaging feature analysis of mixed endometrial stromal and smooth muscle tumors with intracardiac extension.

Authors:  Yi-Yang Liu; Zhan Yu; Rui Wang; Kui-Sheng Chen; Song-Wei Yue; Jun Li; Xue-Mei Gao; Chang-Mao Ding; Zi-Xin Wu; Xi Zhao; Jian-Bo Gao
Journal:  Front Cardiovasc Med       Date:  2022-09-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.