Literature DB >> 20083076

Ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography.

Subodh B Joshi, Dorinna D Mendoza, Daniel H Steinberg, Matthew A Goldstein, Cristian F Lopez, Arnold Raizon, Gaby Weissman, Lowell F Satler, Augusto D Pichard, Wm Guy Weigold.   

Abstract

OBJECTIVES: This study sought to evaluate the feasibility of using ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic (CT) angiography to follow diagnostic cardiac catheterization.
BACKGROUND: Cardiovascular interventions such as percutaneous aortic valve replacement require transfemoral delivery of large-bore intra-arterial catheters; therefore, pre-procedural assessment of aortoiliofemoral anatomy is important. CT angiography is ideal for this purpose but requires a large volume of intravenous contrast.
METHODS: Consecutive patients requiring evaluation of aortoiliofemoral anatomy underwent conventional anteroposterior projection iliac angiography during cardiac catheterization. A pigtail catheter was left in situ in the infrarenal abdominal aorta, and patients were transferred to the CT suite. Subsequently, 10 to 15 ml of contrast diluted with normal saline was injected intra-arterially via the pigtail catheter while a spiral CT of the abdomen and pelvis was acquired. Conventional angiographic and CT images were analyzed independently to assess suitability for large-bore (7-mm-diameter)intra-arterial catheter access.
RESULTS: Excellent CT image quality was achieved in 34 of 37 patients (92%). The mean contrast dose for CT was 12 +/- 2 ml. In 9 patients (24%), CT changed the assessment of femoral access feasibility. Furthermore, in another 7 patients (19%), unfavorable anatomy as shown by CT directed the avoidance of a particular side. Overall, CT findings altered the interventional approach in 16 patients (43%). There was no significant deterioration detected in renal function after coronary and CT angiography (estimated glomerular filtration rate 54.8 +/- 3.8 ml/min before 53.3 +/- 3.9 ml/min after, p = 0.55).
CONCLUSIONS: High-quality aortoiliofemoral CT angiography can be obtained with a technical success rate of >90% using 10 to 15 ml of contrast injected via a catheter in the abdominal aorta, and offers an alternative to conventional X-ray or CT angiography with high-volume intravenous contrast injection.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20083076     DOI: 10.1016/j.jcmg.2009.08.010

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  15 in total

1.  Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: initial experience in a swine model.

Authors:  Uma D Numburi; Samir R Kapadia; Paul Schoenhagen; E Murat Tuzcu; Martin von Roden; Sandra S Halliburton
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-20       Impact factor: 2.357

2.  Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

Authors:  D Ippolito; C Talei Franzesi; D Fior; P A Bonaffini; O Minutolo; S Sironi
Journal:  Br J Radiol       Date:  2015-03-18       Impact factor: 3.039

3.  Spectral detector CT for cardiovascular applications.

Authors:  Prabhakar Rajiah; Suhny Abbara; Sandra Simon Halliburton
Journal:  Diagn Interv Radiol       Date:  2017 May-Jun       Impact factor: 2.630

Review 4.  Noninvasive aortic imaging.

Authors:  Vinit Baliyan; Daniel Verdini; Nandini M Meyersohn
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

5.  Efficacy and safety of endovascular therapy by diluted contrast digital subtraction angiography in patients with chronic kidney disease.

Authors:  Naoki Hayakawa; Satoshi Kodera; Noriyoshi Ohki; Junji Kanda
Journal:  Heart Vessels       Date:  2019-04-15       Impact factor: 2.037

Review 6.  Imaging for surveillance and operative management for endovascular aortic aneurysm repairs.

Authors:  Christopher Lau; Dmitriy N Feldman; Leonard N Girardi; Luke K Kim
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

Review 7.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 8.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

9.  Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose.

Authors:  Benjamin Dubourg; Jérôme Caudron; Jean-Pierre Lestrat; Michael Bubenheim; Valentin Lefebvre; Matthieu Godin; Christophe Tron; Hélène Eltchaninoff; Fabrice Bauer; Jean-Nicolas Dacher
Journal:  Eur Radiol       Date:  2014-06-25       Impact factor: 5.315

10.  Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation.

Authors:  Daniel O Bittner; Martin Arnold; Lutz Klinghammer; Annika Schuhbaeck; Michaela M Hell; Gerd Muschiol; Soeren Gauss; Michael Lell; Michael Uder; Udo Hoffmann; Stephan Achenbach; Mohamed Marwan
Journal:  Eur Radiol       Date:  2016-03-19       Impact factor: 5.315

View more