Literature DB >> 27236818

Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.

Simon S Martin1, Moritz H Albrecht1, Julian L Wichmann2, Kristina Hüsers1, Jan-Erik Scholtz1, Christian Booz1, Boris Bodelle1, Ralf W Bauer1, Sarah C Metzger1, Thomas J Vogl1, Thomas Lehnert1.   

Abstract

OBJECTIVES: To evaluate objective and subjective image quality of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique in dual-energy computed tomography (DECT) angiography prior to transcatheter aortic valve replacement (TAVR).
METHODS: Datasets of 47 patients (35 men; 64.1 ± 10.9 years) who underwent DECT angiography of heart and vascular access prior to TAVR were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monoenergetic (VMI) algorithms in 10-keV intervals from 40-100 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of 564 arterial segments were evaluated. Subjective analysis was rated by three blinded observers using a Likert scale.
RESULTS: Mean SNR and CNR were highest in 40 keV VMI+ series (SNR, 27.8 ± 13.0; CNR, 26.3 ± 12.7), significantly (all p < 0.001) superior to all VMI series, which showed highest values at 70 keV (SNR, 18.5 ± 7.6; CNR, 16.0 ± 7.4), as well as linearly-blended F_0.5 series (SNR, 16.8 ± 7.3; CNR, 13.6 ± 6.9). Highest subjective image quality scores were observed for 40, 50, and 60 keV VMI+ reconstructions (all p > 0.05), significantly superior to all VMI and standard linearly-blended images (all p < 0.01).
CONCLUSIONS: Low-keV VMI+ reconstructions significantly increase CNR and SNR compared to VMI and standard linear-blending image reconstruction and improve subjective image quality in preprocedural DECT angiography in the context of TAVR planning. KEY POINTS: • VMI+ combines increased contrast with reduced image noise. • VMI+ shows substantially less image noise than traditional VMI. • 40-keV reconstructions show highest SNR/CNR of the aortic and iliofemoral access route. • Observers overall prefer 60 keV VMI+ images. • VMI+ DECT imaging helps improve image quality for TAVR planning.

Entities:  

Keywords:  Aortic valve stenosis; Image enhancement; Multidetector-row computed tomography; Transcatheter aortic valve implantation; Transcatheter aortic valve replacement

Mesh:

Substances:

Year:  2016        PMID: 27236818     DOI: 10.1007/s00330-016-4422-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging.

Authors:  Martin Beeres; Jesko Trommer; Claudia Frellesen; Nour-Eldin A Nour-Eldin; Jan E Scholtz; Eva Herrmann; Thomas J Vogl; Julian L Wichmann
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-02       Impact factor: 2.357

2.  CT before transcatheter aortic valve replacement: Value of venous phase imaging for detection and interpretation of findings with impact on the TAVR procedure.

Authors:  Fritz C Roller; Annika Schuhbaeck; Stephan Achenbach; Gabriele A Krombach; Christian Schneider
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-04-01

3.  Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement.

Authors:  Philipp Blanke; Maximillian Russe; Jonathon Leipsic; Jochen Reinöhl; Ullrich Ebersberger; Pal Suranyi; Matthias Siepe; Gregor Pache; Mathias Langer; U Joseph Schoepf
Journal:  JACC Cardiovasc Interv       Date:  2012-09       Impact factor: 11.195

4.  Dual-energy CT: vascular applications.

Authors:  Ioannis Vlahos; Raymond Chung; Arjun Nair; Robert Morgan
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

5.  Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation.

Authors:  Johannes Rixe; Annika Schuhbaeck; Christoph Liebetrau; Helge Moellmann; Holger M Nef; Sebastian Szardien; Roland Brandt; Joern Schmitt; Thomas Neumann; Christian Schneider; Gabriele Krombach; Christian W Hamm; Stephan Achenbach; Andreas Rolf
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

6.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

Authors:  Shuai Leng; Lifeng Yu; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2015-04-10       Impact factor: 11.105

7.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

8.  Virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in head and neck cancer.

Authors:  Julian L Wichmann; Eva-Maria Nöske; Johannes Kraft; Iris Burck; Jens Wagenblast; Anne Eckardt; Claudia Frellesen; J Matthias Kerl; Ralf W Bauer; Boris Bodelle; Thomas Lehnert; Thomas J Vogl; Boris Schulz
Journal:  Invest Radiol       Date:  2014-11       Impact factor: 6.016

9.  Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging.

Authors:  Sonja Sudarski; Paul Apfaltrer; John W Nance; David Schneider; Mathias Meyer; Stefan O Schoenberg; Christian Fink; Thomas Henzler
Journal:  Eur J Radiol       Date:  2013-06-10       Impact factor: 3.528

Review 10.  CT in transcatheter aortic valve replacement.

Authors:  Philipp Blanke; U Joseph Schoepf; Jonathon A Leipsic
Journal:  Radiology       Date:  2013-12       Impact factor: 11.105

View more
  12 in total

1.  Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium.

Authors:  Lu Zhao; Fengtan Li; Zewei Zhang; Zhang Zhang; Yingjian Jiang; Xinyu Wang; Jun Gu; Dong Li
Journal:  Eur Radiol       Date:  2018-04-13       Impact factor: 5.315

2.  Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection.

Authors:  Domenico De Santis; Carlo N De Cecco; U Joseph Schoepf; John W Nance; Ricardo T Yamada; Brooke A Thomas; Katharina Otani; Brian E Jacobs; D Alan Turner; Julian L Wichmann; Marwen Eid; Akos Varga-Szemes; Damiano Caruso; Katharine L Grant; Bernhard Schmidt; Thomas J Vogl; Andrea Laghi; Moritz H Albrecht
Journal:  Eur Radiol       Date:  2019-02-25       Impact factor: 5.315

Review 3.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

4.  Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation.

Authors:  Yanwei Zeng; Kai Deng; Haitao Yang; Yi Tan; Jun Liu; Daoying Geng; Jun Zhang
Journal:  Eur Spine J       Date:  2019-04-30       Impact factor: 3.134

5.  Advances in cardiac CT contrast injection and acquisition protocols.

Authors:  Jan-Erik Scholtz; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

6.  Dual-energy computed tomography for evaluation of breast cancer: value of virtual monoenergetic images reconstructed with a noise-reduced monoenergetic reconstruction algorithm.

Authors:  Kanako Okada; Megumi Matsuda; Takaharu Tsuda; Teruhito Kido; Akihiro Murata; Hikaru Nishiyama; Kanako Nishiyama; Haruna Yamasawa; Yoshiaki Kamei; Mie Kurata; Mana Fukushima; Riko Kitazawa; Teruhito Mochizuki
Journal:  Jpn J Radiol       Date:  2019-11-04       Impact factor: 2.374

7.  Optimized energy of spectral CT for infarct imaging: Experimental validation with human validation.

Authors:  Veit Sandfort; Srikanth Palanisamy; Rolf Symons; Amir Pourmorteza; Mark A Ahlman; Kelly Rice; Tom Thomas; Cynthia Davies-Venn; Bernhard Krauss; Alan Kwan; Ankur Pandey; Stefan L Zimmerman; David A Bluemke
Journal:  J Cardiovasc Comput Tomogr       Date:  2017-02-11

8.  Multiparametric dual-energy CT to differentiate stage T1 nasopharyngeal carcinoma from benign hyperplasia.

Authors:  Hesong Shen; Xiaoqian Yuan; Daihong Liu; Chunrong Tu; Xing Wang; Renwei Liu; Xiaoxia Wang; Xiaosong Lan; Kaiwen Fu; Jiuquan Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-09

9.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

10.  Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.

Authors:  Tommaso D'Angelo; Andreas M Bucher; Lukas Lenga; Christophe T Arendt; Julia L Peterke; Damiano Caruso; Silvio Mazziotti; Alfredo Blandino; Giorgio Ascenti; Ahmed E Othman; Simon S Martin; Doris Leithner; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.