Literature DB >> 24366822

Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Y Du1, J M Links, L Becker, A F DiPaula, T Frank, K H Schuleri, A C Lardo, E C Frey.   

Abstract

BACKGROUND: Simultaneous (201)Tl/(99m)Tc-sestamibi dual-isotope myocardial perfusion SPECT imaging can reduce imaging time and produce perfectly registered rest/stress images. However, crosstalk from (99m)Tc into (201)Tl images can significantly reduce (201)Tl image quality. We have developed a model-based compensation (MBC) method to compensate for this crosstalk. The method has previously been validated with phantom and simulation studies. In this study, we evaluated the MBC method using a canine model.
METHODS: Left anterior descending or left circumflex coronary artery stenoses were created in 50 adult mongrel dogs weighing 20-30 kg. The dogs were injected with 111 MBq (3 mCi) of (201)Tl at rest, and a SPECT study acquired. Stress was induced by administering adenosine to the dog, followed by injection of 740 MBq (20 mCi) of (99m)Tc-sestamibi at peak stress. A second SPECT study was performed with data acquired in both (201)Tl and (99m)Tc energy windows to provide simultaneous dual-isotope projection data. The images were reconstructed using the ordered-subsets expectation-maximization reconstruction algorithm with compensation for attenuation, scatter, and detector response. For simultaneously acquired (201)Tl data, we also applied the MBC method to compensate for crosstalk contamination from (99m)Tc.
RESULTS: Without compensation, (99m)Tc crosstalk increased the estimated (201)Tl activity concentration in the rest images and reduced defect contrast. After MBC, the (201)Tl images were in good agreement with the registered single-isotope images and ex vivo count data. The ischemic (IS) to non-ischemic (NIS) region (201)Tl activity concentration ratios were computed for single-isotope and dual-isotope studies. The correlation with ex vivo IS-NIS ratios was 0.815 after MBC, compared to the 0.495 from data without compensation. In addition, the regression line for the IS-NIS ratios with MBC was almost parallel to the line of identity with a slope of 0.93, compared to a slope of 0.45 without compensation.
CONCLUSIONS: These results demonstrate that model-based crosstalk compensation can provide substantial reduction of crosstalk effects in simultaneously acquired myocardial perfusion SPECT images in living biological systems.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24366822      PMCID: PMC4116681          DOI: 10.1007/s12350-013-9842-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  26 in total

1.  Rapid SPECT simulation of downscatter in non-uniform media.

Authors:  H W de Jong; F J Beekman
Journal:  Phys Med Biol       Date:  2001-03       Impact factor: 3.609

2.  Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease.

Authors:  M Nakamura; K Takeda; T Ichihara; N Motomura; H Shimizu; Y Saito; Y Nomura; N Isaka; T Konishi; T Nakano
Journal:  J Nucl Med       Date:  1999-06       Impact factor: 10.057

3.  Photon energy recovery for crosstalk correction in simultaneous 99mTc/201Tl imaging.

Authors:  P Hannequin; J Mas; G Germano
Journal:  J Nucl Med       Date:  2000-04       Impact factor: 10.057

4.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

Authors:  G L Zeng; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

Review 5.  Developments in cardiac-specific SPECT imaging.

Authors:  B F Hutton
Journal:  Q J Nucl Med Mol Imaging       Date:  2012-06       Impact factor: 2.346

6.  A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Anna Leykekhman; Linda B Thompson; Marvin Friedman
Journal:  J Nucl Cardiol       Date:  2011-02-02       Impact factor: 5.952

7.  Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.

Authors:  Krzysztof Kacperski; Kjell Erlandsson; Simona Ben-Haim; Brian F Hutton
Journal:  Phys Med Biol       Date:  2011-02-11       Impact factor: 3.609

8.  Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior.

Authors:  Xin He; Lishui Cheng; Jeffrey A Fessler; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2010-10-14       Impact factor: 10.048

9.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

10.  Assessment of severity of coronary artery stenosis in a canine model using the PET agent 18F-fluorobenzyl triphenyl phosphonium: comparison with 99mTc-tetrofosmin.

Authors:  Igal Madar; Hayden Ravert; Antony Dipaula; Yong Du; Robert F Dannals; Lewis Becker
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

View more
  5 in total

1.  Simultaneous Evaluation of Safety, Acceptability, Pericoital Kinetics, and Ex Vivo Pharmacodynamics Comparing Four Rectal Microbicide Vehicle Candidates.

Authors:  Francisco Leyva; Edward J Fuchs; Rahul Bakshi; Alex Carballo-Dieguez; Ana Ventuneac; Chen Yue; Brian Caffo; Yong Du; Michael Torbenson; Liye Li; Gerald Mullin; Linda Lee; Lisa Rohan; Peter A Anton; Craig W Hendrix
Journal:  AIDS Res Hum Retroviruses       Date:  2015-07-08       Impact factor: 2.205

2.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

3.  A Phase 1 Randomized, Blinded Comparison of the Pharmacokinetics and Colonic Distribution of Three Candidate Rectal Microbicide Formulations of Tenofovir 1% Gel with Simulated Unprotected Sex (CHARM-02).

Authors:  Hiwot Hiruy; Edward J Fuchs; Mark A Marzinke; Rahul P Bakshi; Jennifer C Breakey; Wutyi S Aung; Madhuri Manohar; Chen Yue; Brian S Caffo; Yong Du; Kaleab Z Abebe; Hans M L Spiegel; Lisa C Rohan; Ian McGowan; Craig W Hendrix
Journal:  AIDS Res Hum Retroviruses       Date:  2015-08-24       Impact factor: 2.205

4.  Simultaneous SPECT imaging of multi-targets to assist in identifying hepatic lesions.

Authors:  Zhide Guo; Mengna Gao; Deliang Zhang; Yesen Li; Manli Song; Rongqiang Zhuang; Xinhui Su; Guibing Chen; Ting Liu; Pingguo Liu; Hua Wu; Jin Du; Xianzhong Zhang
Journal:  Sci Rep       Date:  2016-07-05       Impact factor: 4.379

Review 5.  Theranostic Pretargeting Drug Delivery and Imaging Platforms in Cancer Precision Medicine.

Authors:  Sudath Hapuarachchige; Dmitri Artemov
Journal:  Front Oncol       Date:  2020-07-22       Impact factor: 6.244

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.